HomeMy WebLinkAbout83-1860SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK CRAWLSPACE FLOOR ELEVAI LEACHING: 15' PERIMETER: 121 LF x 0.83 x 0.74 = 74 GPD BOTTOM AREA: 520 SF (0.74) =384 GPD TOTAL: 618 S.F. 458 GPD USE 7 H-20 HIGH CAPACITY INFILTRATORS IN CONFIGURATION SHOWN (SEE DETAIL) ACCESS STAIRS) APPROVED , MA DATE BOARD OF HEALTH LEGEND- EGEND99 99- EXISTING CONTOUR + 88.I EXIST. SPOT ELEV. 150' PROPOSED CONTOUR s9 PROPOSED SPOT EL. TH1 SIDE SETBACK 15' TESTIHOLE 2� SLOPE OF GROUND �Q> UTILITY POLE A FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING 02-340 PROVIDE WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 12.0' MINIMUM .75' fOF COVER OVER PRECAE PRECAST H-10 RISERS (TYPJ r z•m 1 SYSTEM PROFILE (NOT TO SCALE) 4"•SCH40 PVC PIPES LEVEL 1ST 2' U l0' 14; - jQ,Q6' TEE 1500 GAL H-10 TEE 9 81, SEPTIC TANK u 6 MIN. SUMP 4' LIG. LEVEL o 00000a000QooVoc 12 MIN. INT. DIM. o GAS BAFFL 0 00°0°0°0°0°0 0° 9, ACME OR EQUAL ° °0°02o°o°c°o o� 9.78' 9.61' gags 0000000000000000000000oc O O O o O 0 O 0 O O O C 0 0 0,0„0„0 0� 0�0 0 0„0, 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2n D'BOX TO BE WATER -TESTED FOR LEVELNESS (_L5_X SLOPE) FOUNDATION.- 11' - SEPTIC TANK (_% SLOPE) - 3' - NOTE: FLOOOZONE DESIGN FOUNDATION BY OTHERS. FINAL GRADING TO BE IN ACCORDANCE WITH FEMA FLOODZONE REGULATIONS SAS DETAIL 1"=20' - D' BOX (_1X SLOPE) - 10' - ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE, MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORT TO WITHIN 3. OF FINAL GRADE 2% SLOPE REQUIRED OVER SYSTEM / 11' - 12' 2" PEASTONE OR GEOTEXTILE FILTER FABhIb OVER STONE 10.0' HIGH CAPACITY • INFILTRATORS TO DOUBLE WASHED STONE USE ADJ. GROUNDWATER AT EL. 3.7'* LEACHING FACILITY *NOTE: OBSERVED GROUNDWATER ELEVATIONS IN ALL TEST HOLES WERE WITHIN 3 INCHES. GROUNDWATER IN THIS AREA CAN BE INFERRED TO BE AFFECTED BY NEARBY NANTUCKET SOUND (GROUNDWATER ADJUSTMENT DATA FOR 2002 HOLES ARE NOT INDICATIVE OF REALISTIC HIGH GROUNDWATER ELEVATIONS) CONC. BOUND ELEV. 10.0 (NGVD) -1- 9.1 I 9,9 .. pGCp1 1 PROPOSED CB FNP DRIVE. 176.56' 10.9 TH 2 1 x * 10.2 N �i 11, LOT 11 A) N - I o< O + 13,111± SQ. FT. o �.� \ 0.30± ACRES ro --_� I Of Q4 \ \�•�• _-\\ rrr--- II 111 56..24.00' _ '� I > r`. \ \+ 1\ 3 \;�r_'_ w• I + 10.3 1p fr \ \ 1\TM 1 +10.0 ' 10 +10.4 m p \\ \ `0 SnNO `1\ PROP. DWELLING Ij + 10.3 1 G� \ ` R �\ ` 10.0 + 9 TOP FNDN. I GARAGE I 0 q0 SHED ELEV. 13.0 1 0 1Li 9L \ \`\ f� \ EXIST. A + 9. WATER METER PIT 1 00 9.3 \ p \ �O \ F 24. c VIII 1 r� 90 1 I �J O \ \ \ + + .1 I O \ p V \ p \\ X0311 > 0 213.00 _ COO d \ d 1 PROP. 1 DECK I 2+ 05 v / I 000 ' 3 I PROVIDE APPROX. 60' OF 40 , MIL LINER AT 5' OFF PORTION 0 4�� �-. ? I OF PERIMETER OF SAS. TOP O N G �� O+ - + 10.1 AT ELEV. 10, BOTTOM AT EL. p O Q`�.r�' io EXIST. DWELL.ONC. BOUND 1 6 \ 1103 O/ / 1 23.08' - + 9.4 \ C FND 11.6 \ t 9.7 1 X+ 9. 5' REMOVAL OF UNSUITABLE SOIL REQUIRED NOTE: INVERT INTO SAS IS BELOW THE AROUND PERIMETER OF LEACHING FACILITY, CRAWLSPACE FLOOR ELEVATION - - - - --DOWN TO SUITABLE SOIL LAYER. REPLACE / NTH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) 2',j MUNICIPAL WATER IS EXISTING 3 MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4 DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS T BE AASHO H-14 5 PIPE JOINTS TO BE MADE WATERTIGHT. 6 CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 3 0 CMR 15.000 (TITLE V.) 7 THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO B USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. fL PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9 COMPONENTS NOT TO BE BACKFILLED OR CONCEALED THOUTINSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES P IOR TO COMMENCEMENT OF WORK. 1 . ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE R MOVED 5' BENEATH AND AROUND THE PROPOSED L ACHING FACILITY, 1 . EXISTING SEPTIC SYSTEM SHALL BE PUMPED AND REMOVED 13. ALL ROOF RUN-OFF TO BE INFILTRATED INTO ZONING SUMMARY ZONING DISTRICT: R-25 MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. LOT COVERAGE: 25% A PROP. LOT COVERAGE: 24.3% (INCLUDES ALL DECK AND ACCESS STAIRS) ELEV. OWNER OF RECORD FRANCIS AND DIANNE CLORAN 36 NOTTINGHAM DRIVE KINGSTON, MA REFERENCES CTF 138794 LCP 18413-D (LOT 11) TEST HOLE LOGS ENGINEER: RICK JUDD, RS WITNESS: AMY VON HONE, RS DATE: 11 /20/02 PERC. RATE = < 2 MIN/INCH CLASS I SOILS ELEV ELEV GROUNDWATER ADJUSTMENT DATA: WELL: MIW 29 ZONE: A ADJ: 2.3' - � DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 25 PARCEL 126 LOCUS IS WITHIN FEMA FLOOD ZONE A9 ELEV. 10 (PORTION OF LOT IN B) ON COMMUNITY PANEL #250015 0006 D JULY 2, 1992 TEST HOLE LOGS 4 ENGINEER: ARNE 0" Scale: 1 "= 20' 10.5' 0" 0 10 20 9.5' FILL FILL 5" 2" PERC. RATE A down cope A CLASS 1 SOILS civil engineers SL ELEV. LS 011 02-340.DWG( 1OYR 2/1 10YR 2/1 FILL 7" FILL 4" A E E SL LS LS 15" 1OYR 5/2 9" 1OYR 5/2 1OYR 2/1 Bw Bw g' LS E LS 28" 1OYR 5/6 8.2' 25" 10YR 5/6 7.4' C1 12" C1 PERC LFS - LFS 56- 2.5Y 6/4 46" 2.5Y 6/4 B ADJ WATER OBS. WATER 96" 104" 5.0' 2.75' 1.8' C2 FS 2.5Y 6/3 4.8' 2.5' 1.8' 92" SAIER LFS 2.5Y 6/6 GROUNDWATER ADJUSTMENT DATA: WELL: MIW 29 ZONE: A ADJ: 2.3' - � DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 25 PARCEL 126 LOCUS IS WITHIN FEMA FLOOD ZONE A9 ELEV. 10 (PORTION OF LOT IN B) ON COMMUNITY PANEL #250015 0006 D JULY 2, 1992 GROUNDWATER ADJUSTMENT DATA: WELL: MIW 29 ZONE: A ADJ: 1.1' OF 60 F'AHK\N000 HUHU SOUTH YARMOUTH PREPARED FOR M/M FRANCIS CLORAN ELEV. 10.4' 3.6' 2_5' 0.4' JULY TEST HOLE LOGS 2009 (SEPTIC) ENGINEER: ARNE H. OJALA, PE, SE Scale: 1 "= 20' WITNESS: AMY VON HONE, RS 0 10 20 30 40 50 FEET DATE: 5/14/09 off 508-362-4541 fax 508-362-9880 PERC. RATE _ < 2 MIN/INCH down cope engineering, MC. CLASS 1 SOILS civil engineers Q ELEV. 4 011 02-340.DWG( 10,1' 0" 4„ FILL 4' FILL A A SL SL 1OYR 2/1 1OYR 2/1 6" g' E E FS FS 12" 2.5Y 7/1 12" 2.5Y 7/1 B _ _ B LFS LFS 28" 2.5Y 5/6 7.7' 42" 2.5Y 5/6 PERC ® C C LFS LFS J�� 3.7' J. WATER - S.__WATE 2.6' 94"S. V TER - 90" 2.5Y 5/6 2.5Y 5/6 120" 0_1' 120" GROUNDWATER ADJUSTMENT DATA: WELL: MIW 29 ZONE: A ADJ: 1.1' OF 60 F'AHK\N000 HUHU SOUTH YARMOUTH PREPARED FOR M/M FRANCIS CLORAN ELEV. 10.4' 3.6' 2_5' 0.4' JULY 15, 2009 AUGUST 5, 2009 (SEPTIC) REV DEC. 16, 2009 (LESS FILL) Scale: 1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 fax 508-362-9880 downcope.com down cope engineering, MC. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 02-340.DWG( I , s4)kI L -AI. nrr.'l DAT✓ry //� SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK CRAWLSPACE LEACHING: PERIMETER: 121 LF x 0.83 x 0.74 = 74 GPD BOTTOM AREA: 520 SF (_0.74)=384 GPD TOTAL: 618 S.F. 458 GPD USE 7 H-20 HIGH CAPACITY INFILTRATORS IN CONFIGURATION SHOWN (SEE DETAIL) APPROVED , MA DATE BOARD OF HEALTH LEGEND- EGEND99 99- EXISTING CONTOUR + 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 99 PROPOSED SPOT EL. TH1 SIDE SETBACK 15' TEST HOLE 2� SLOPE OF GROUND CQ-) UTILITY POLE rr FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING SAS DETAIL 1"=20' 02-340 PROVIDE WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 12.0' MINIMUM .75'+0F COVER OVER PRECA; PRECAST 8-10 RISERS (TYP.) z•m SYSTEM PROFILE ALL SYSTEM SHALL MARKED WITHCOMPONENTS MAGNETIC TAPE OR BE (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE 2% SLOPE REQUIRED OVER SYSTEM / 11' - 12' 4"0SCH40 PVC PIPES LEVEL IST 2' 2" PEASTONE OR GEOTEXTILE FILTER FABI�I� OVER STONE to, la" 10.0' ' TEE 1500 GAL H-10 TEE ' 10.06 SEPTIC TANK 9.81 0c000o _00000 c0°� 6" MIN. SUMP 4' LIQ. LEVEL o 0°0°0°0°000° °c 12" MIN. INT. DIM. GAS BAFFLE -_0. 000000 ACME OR EQUAL 0 000000000000 0° 9.78' 9.61' �8 0.63' uO ,O O :o, o. ; O •o. O o ,o iC o B.T 000000000000 0 0 0 0 0 0 HIGH CAPACITY H-20 INFILTRATORS 000000°000°0°0°0°0C 6" CRUSHED STONE OR MECHANICAL 3/4" TO 1 1/2- DOUBLE WASHED STONE COMPACTION. (15.221 [2]) 5.0' D'BOX TO BE WATER -TESTED FOR LEVELNESS USE ADJ. GROUNDWATER AT EL. 3.7'* ('-•"x SLOPE) (--l.% SLOPE) (� SLOPE) FOUNDATION- 11' - SEPTIC TANK 3' D' BOX 10' LEACHING FACILITY *NOTE: OBSERVED GROUNDWATER ELEVATIONS IN ALL TEST HOLES WERE WITHIN 3 INCHES. GROUNDWATER IN THIS AREA CAN BE INFERRED TO BE AFFECTED BY NEARBY NANTUCKET SOUP (GROUNDWATER ADJUSTMENT DATA FOR 2002 HOLES ARE NOT INDICATIVE OF REALISTIC HIGH GROUNDWATER ELEVATIONS) NOTE: FLOODZONE DESIGN FOUNDATION BY OTHERS. FINAL GRADING TO BE IN ACCORDANCE WITH FEMA FLOODZONE REGULATIONS �k li. LOT 11 \+ 13,111± SQ. FT. \ -0.301 ACRES \ � � •_•tet ,\ TH 1 O \\ �\` 9L \ O \ > O \ o 0 d \0 FriSTN \\ / SFR h\ " 10.0 NOTES 1. DATUM IS NGVD 2. MUNICIPAL WATER.IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1,Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND do OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING SEPTIC SYSTEM SHALL BE PUMPED AND REMOVED 13. ALL ROOF RUN-OFF TO BE INFILTRATED INTO DRYWELLS ZONING SUMMARY ZONING DISTRICT. R-25 MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. LOT COVERAGE: 25% PROP. LOT COVERAGE: 24.3% (INCLUDES ALL DECKS AND ACCESS STAIRS) OWNER OF RECORD FRANCIS AND DIANNE CLORAN 36 NOTTINGHAM DRIVE KINGSTON, MA REFERENCES CTF 138794 LCP 18413-D (LOT 11) LOCUS MAP NOT TO SCALE ASSESSORS MAP 25 PARCEL 126 LOCUS IS WITHIN FEMA FLOOD ZONE A9 ELEV. 10 (PORTION OF LOT IN 8) ON COMMUNITY PANEL #250015 0006 D JULY 2, 1992 TEST HOLE LOGS TEST HOLE LOGS ENGINEER: RICK JUDD, RS ENGINEER: ARNE H. OJALA, PE, SE WITNESS: AMY VON HONE, RS WITNESS: AMY VON HONE, RS DATE: 11 /20/02 DATE:- 5/14/09 PERC. RATE _ < 2 MIN/INCH PERC. RATE = < 2 MIN/INCH CLASS I SOILS CLASS -'--SOILS ELEV. ELEV. ELEV. ELEV. 0„ ;4 10.5' p" Q 9_5' 0„ 4 10.1' 0" 4 10.4' 5" FILL 2" FILL 4„ FILL 4" FILL A A A A CONC. BOUND SL LS SL SL ELEV. - 10.0 10YR 2 10YR 2 1 1 (NGVD) 7„ / 4„ / 1OYR 2/1 1OYR 2/1 t 9.1 g 6„ I E 404--+ 9.9 9'9 mot I PROPOSED LS LS E E CB FN� DRIVE. FS FS 176.56' TH 2 " 1OYR 5/2 g" 10YR 5/2 1o.9 ® I 15 - 12" 2.5Y 7/1 12" 2.5Y 7/1 Bw Bw e N N -- 1 o p LS LS LFS N LFS 28" 28" 1OYR 5/6 8.2' 25" 10YR 5/6 7.4' 28" 2.5Y 5/6 7.7' 42° 2.5Y 5/6 6.9' Imo---- It v 24.00' _ I Q �• i + 10.3 p 1 Cof 7 PERC F C1 FLFS LFS PERC ® C C + 10.0 1 1 o , LFS LFS + 10.4 i + 1a.3 a " 2.5Y 6/4 46" 2.5Y 6/4 J�ATE 3, 7' J� 3.6' PROP. DWELLING I g w ,� + 9 TOP FNDN. = I GARAGE o i o r1. ADJ WATER C2 4.8' R 5 0 2.6' 2.5' SHED ELEV. 13.0' 1 n „ 90" S._W(ATE 94„ S. -ALTS + 9. EXIST, i W 1 OBS. WATER 96 FS 2.5 , n 2.5Y 2.75' 2.5Y 5/6 2.5Y 5/6 WATER METER PIT , 6.0 _ 24 s.3 q 104 2.5Y 6/3 1.8 92 1.8' 120" 0_1' 120" 0_4 I + b 26.00 _ _ _ 3- _ I �1 GROUNDWATER ADJUSTMENT DATA: GROUNDWATER ADJUSTMENT DATA: o I WELL: MIW 29 WELL: MIW 29 � r DECK i I ZONE: A ZONE: A n I __ Q Q Q '3 PROVIDE APPROX. 60' OF 40 ADJ: 2.3' ADJ: 1.1' 10,5 0 1 MIL LINER AT 5' OFF PORTION �` I OF PERIMETER OF SAS. TOP +10.1 AT ELEV. 10, BOTTOM AT EL. INV EXIST. DWELL. ONC. BOUND 6 II 0 123.08' + 9.a FND11.6 N + 9.7 TITLE ITIFLAN 9. 5' REMOVAL OF UNSUITABLE SOIL REQUIRED OF NOTE: INVERT INTO SAS IS BELOW THE AROUND PERIMETER OF LEACHING FACILITY, CRAWLSPACE FLOOR ELEVATION - - - DOWN SUITABLE SOIL. LAYER. REPLACE - - - P -� W ®O D ROAD WITH CLEAN MED. SANDND, MI MEET SPECIFICATIONS OF 310 CMR 15.255(3) SOUTH YARMOUTH OJALA CIVIL No. 46502 DANIEL A. OJALA No. 40980 DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR M/M FRANCIS CLORAN JULY 15, 2009 AUGUST 5, 2009 (SEPTIC) REV DEC. 16, 2009 (LESS FILL) Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 fax 508-362-9880 downcope.com dorm cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 I IT I. 02-340.DWG(SBO) off;'