HomeMy WebLinkAbout83-1877 - Site & Sewage Disposal (2)GENERAL NOTES: A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM UNLESS H-20 COMPONENTS ARE USED. B.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UN- LE55 CONSTRUCTED AS SHOWN.ANY CHANGES SHALL BE APPROVED IN WRITING. C.) CONTRACTOR SHALL BE RE5PON51BLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. CONSTRUCTION NOTES: 1 .) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE. - TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH. 2.) SEPTIC TANK(5), GREASE TRAF(5), DOSING CHAMBER(5) AND DISTRIBUTION 13OX(E5) SHALL BE SET ON A LEVEL STABLE BASE WHICH HA5 BEEN MECHANICALLY .COMPACTED, OR ON A (i INCH CRUSHED STONE BASE. 3.) SEPTIC TANK(S) SHALL MEET A5TM STANDARD C 1 127-93 AND SHALL HAVE AT LEAST 7HREE20" DIAMETER MANHOLES, THE MINIMUM DEPTH FROM THE BOT- TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48". 4.) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A MINIMUM OF G" ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE. 5.) RAI5E COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN G" OF FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT. G.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LE55 THAN I %. 7.) DISTRIBUTION LINES FOR SOIL ABSORPTION SYSTEM (AS REQUIRED) SHALL BE 4" DIAMETER SCHEDULE 40 PVC LAID AT 0.005 FT/FT. LINE SHALL BE CAPPED AT END OR AS NOTED. 8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST 2' BEFORE PITCHING TO SOIL ABSORPTION SYSTEM. WATER TEST DISTRIBUTION BOX TO ASSURE EVEN DISTRIBUTION. 9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP OF G" MEASURED BELOW THE OUTLET INVERT. 10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CONSIST OF 3/4" TO 1-1/2" DOUBLE WASHED STONE FREE OF IRON, FINES AND DUST AND SHALL BE INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE 501L ABSORPTION SYSTEM. BASE AGGREGATE SHALL BE COVERED WITH AO' LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE FREE OF IRON, FINES AND DUST. 1 1.) VENT 501L ABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET; WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS, TURNING AREAS OR OTHER IMPERVIOUS MATERIAL; OR WHEN PRESSURE DOSED. 12.) SOIL ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9" OF CLEAN MEDIUM SAND (EXCLUDING TOPSOIL). 13.) FINISH GRADE SHALL BE A MAXIMUM OF 36" OVER THE TOP OF ALL SYSTEM COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, DOSING CHAMBER AND SOIL ABSORPTION SYSTEM, SEPTIC TANKS SHALL HAVE A MINIMUM COVER OF 9". 14.) FROM THE DATE OF INSTALLATION OF THE SOIL A55ORFTION SYSTEM UNTIL RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL ABSORP- TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM. 15.) THE BOARD OF HEALTH SHALL REQUIRE INSPECTION OF ALL CONSTRUCTION BY AN AGENT OF THE BOARD OF HEALTH (OR THE DESIGNER IF THIS SYSTEM RE- QUIRES A VARIANCE) AND MAY REQUIRE SUCH PERSON TO CERTIFY IN WRITING THAT ALL WORK HAS BEEN COMPLETED M ACCORDANCE WITH THE TERMS OF THE PERMIT AND APPROVED PLANS. 48 HOURS ADVANCE NOTICE 15 REQUESTED. I G.) ALL TOPSOIL i SUBSOIL (A t B) ENCOUNTERED WITHIN 5' AROUND THE 5.A.5. SHALL BE REMOVED DOWN TO THE CLEAN SAND AND REPLACED WITH CLEAN SAND, COMPACTED TO MINIMIZE SETTLEMENT. 17.) ALL FILL USED ON PROJECT SHALL BE CLEAN AND FREE OF DEBRIS. FILL SHALL BE PLACED IN 6-8" LIFTS AND BE COMPACTED TO 95% OF MAXIMUM DRY DENSITY AS PER AA5110 T 180, METHOD D. FILL TO BE USED SHALL CONFORM TO 310 CMR 15.255 (3). CONSERVATION NOTES: 1 .) LIMIT OF WORK SHALL BE AS SHOWN ON PLAN VIEW. THE LIMIT OF WORK SHALL CONSIST OF DOUBLE STAKE? HAYBALES OR SILT BARRIER AS CONDITIONED BY CONSERVATION COMMISSION AND SHALL BE CONSTRUCTED PRIOR TO ANY WORK ON THE PROJECT. 2.) ROOF RUN-OFF SHALL BE CONT OLLED THROUGH GUTTER, DOWNSPOUTS, 4 DRY -WELLS OR BY STONE TRENCHES (2'x P) LOCATED UNDER ALL DRIP LINES. 3.) ALL DISTURBED AREAS SHALL BE REVEGETATED UPON THE COMPLETION OF THE PROJECT. 4.) ALL FILL REQUIRED FOR THE PROJECT SHALL BE CLEAN SAND, FREE OF DEBRIS AND GARBAGE. UN -USED MATERIAL SHALL BE REMOVED FROM PROPERTY. pir FINISH WITH BLACK n BARK MULCH roe O s Will.. A FO r �a l.wx ih i .t t" Fns a Oc0 `'u `' O 13EARBERRY 2 GAL. MIN SHORE JUNIPER 2 GAL. MIN PLANTING DETAIL: d y,o SCALE 1 "=20' FLOW PPOFI LE: NOT TO SCALE 24" DIAMETER CONCRETE COVERS RAISED TO WITHIN G" OF FIN15H FINISH FLOOR GRADE (OR AS NOTED) EL= I G.O± (SEE NOTE #5) _, Proposed EL= I 1.5t I 10.0± 9.50 LL 110„ I I4i. 3a 4'0" GAS BAFFLE 23 ± 1 500 GALLON SEPTIC TANK SOIL TEST LOGS: TEST PIT 1; EL -5. _ 3 DEPTH FROM 501L SOIL SOIL SOIL OTHER SURFACE HORIZON TEXTURE COLOR MOTTLING (INCHES) (USDA) (MUN5ELL) 0-10 A Loamy Fine Sand I CYR 3 NONE NONE 10-24 B Loannv Fine Sand I CYR 5/6 NONE - 26-81 24-84 C I Loamy Sand I OYR 7/8 NONE Pero 24" CI Groundwater EL=44" Groundwater EL=58" NONE Loose Wee in H2O 42" Groundwater @ EL=40" TEST PIT 2: EL=6.2± DEPTH FROM 501L SURFACE HORIZON (INCHES) 501L 501L SOIL OTHER TEXTURE COLOR MOTTLING (USDA) (MUN5ELL) 0-7 A Loanny Fine Sand I OYR 3/3 NONE 7-26 B I o3nny Fine Sand I OYR 5/8 NONE - 26-81 Cline Sand I OYR G/4 NONE Pere A 58" I GYP G14 NONE CI Groundwater EL=44" Groundwater EL=58" TE5T PIT 3: EL=5.8± DEPTH FROM SOIL SOIL SOIL 501L SURFACE HORIZON TEXTURE - COLOR MOTTLING (INCHES) I (1-51DA) (MUN5ELU OTHER 0-9 A Loam Fine Sand I CYR 3/3 NONE B 9-26 B Loam Fine Sand I CYR 5/8 NONE Loamy Sand 26-82 C I fine Sand I GYP G14 NONE CI Groundwater EL=44" IGYP 6G NONE Loose Wee in H2O 42" 83-108 Groundwater EL=49" TEST PIT 4: EL=5.3± DEPTH FROM SOIL SOIL SOIL SOIL OTHER SURFACE HORIZON TEXTURE COLOR MOTTLING (INCHES) (USDA) (MUN5ELL) 0-8 A -7Loamv Fine Sand I OYR 3/3 NONE 8-25 B Loam Fine Sand 1 OYR 5/8 ONE 25-83 Cl Loamy Sand I CYR 7/8 NONE NONE Friable 17-83 CI Groundwater EL=44" DATE OF TESTING: 04122110 PERCOLATION RATE: LE55 THAN 2 MIWINCH IN "C" LAYERS. WITNESSED BY: KEITH E. FERNANDE5, EIT, J.M. DREILLY 4 ASSOCIATES, INC. AMY VON HONE, AGENT, YARMOUTH HEALTH DEPARTMENT STANDING GROUNDWATER ENCOUNTERED AS NOTED USE A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF SOIL ABSORPTION 5Y5TE'M. SOIL TEST LOGS: HAND BORING 1 : EL=5. 1 ± DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOIL TEXTURE - (USDA) 501L COLOR - - (MUN5ELU 501L MOTTLING I OTHER 0-11 A Fine Sand I GYP. NONE Loose 11-17 B Pine Loamy Sand IGYP 44 NONE Friable 17-83 CI Medium Loanny Sand IGYP 6G NONE Loose Wee in H2O 42" 83-108 C2 Fine Sand I GYP 6/2 NONE Very Friable 04-10-10 EL=2.40 SEPTIC TANK CAPACITY PROVIDED: HAND BORING 2: EL=4.9± DEPTH FROM SURFACE (INCHES) SOIL HORIZON 501L TEXTURE (USDA) - - SOIL COLOR .(MUN5ELL) SOIL MOTTLING I OTHER, 0-7 A Fine Sand I CYR 5/1 NONE Loose 7-19 B Fine Loamy Sand I GYP 4/4 NONE Friable 19-52 Cl Medium Loamy Sand I OYR G16 NONE Loose. Wee in H2O 40" 52-103 C2 fine Sand i OYR G/2 NONE Very Enable 04-10-10 EL=2.40 SEPTIC TANK CAPACITY PROVIDED: DATE OF TESTING: 09/04/96 PERCOLATION RATE: LESS THAN 2 MIWINCH IN "O' LAYERS, WITNE55ED BY: MATTHEW T. FARREL, EIT, J.M. O'KEILLY 4 A55OC11,TE5, INC. AMY VON HONE, AGENT, YARMOUTH HEALTH DEPARTMENT NO WATER ENCOUNTERED USE A LOADING RATE OF 0.74 GPD/5F FOR SIZING OF 501L ABSORPTION SYSTEM, BUILDING COVERAGE: SHOWER 40.0 SF WALLS 70.0 SF TOTAL 4,159.1 5F SYSTEM DESIGN CALCULATIONS: DWELLING 1,877.2 5F LOG WOOD DECK 607.7 SF 1 -05-96 EL=2.6 IDROOM POOL 738.8 SF 4 BEDWELLING @ I I 0 GPD = 440 GPD POOL DECK 607.4 SF POOL TROUGH 81.8 5F - I -9E EL=2.49 ENTRY 193.2 SF SHOWER 40.0 SF WALLS 70.0 SF TOTAL 4,159.1 5F SYSTEM DESIGN CALCULATIONS: MONITOR WELL LOG SEWAGE DESIGN FLOW: 1 -05-96 EL=2.6 IDROOM 4 BEDWELLING @ I I 0 GPD = 440 GPD - I -9E EL=2.49 LEACHING CAPACITY REQUIRED: 4 BEDROOMS (MAXJ @ 110 GPD = 440 GPD REQUIRED 1 1 - 1 <'I-96 EL=2.25 SEPTIC TANK CAPACITY REQUIRED: I 1 -25-96 EL=2.25 DAILY FLOW = 440 GPD @ 200% = 880 GAL. REQUIRED 04-10-10 EL=2.40 SEPTIC TANK CAPACITY PROVIDED: 1 500 GALLON SEPTIC TANK (MIN. ALLOWED) EL=2.75 HISTORIC HIGH GROUNDWATER LEACHING CAPACITY PROVIDED: ONE (1) 45.0' X 15.0- X G" LEACH FIELD CAN LEACH: o O Vt = (45.0 X 15.0) X 0.74 GPD/5F=499.5 GPD 499 GPD>440 GPD REQUIRED - NOTE: A GARBAGE DISPOSAL 15 NOT PERMITTED WITH THI5 DESIGN. w w w INSTALL Q a z ONE (1) - 1 500 GALLON SEPTIC TANK N N ONE (1) - 3 OUTLET DISTRIBUTION BOX (11-20 Rated) O - ONE (1) - 45.0' x 1 5.0' x G" LEACH FIELD Q FL PROPOSED I EL=4.5± V GRADE. J 5 ---.-,._ ... ....... Existing ... - -"--G" .. Grade DEEP 5TONEN BED @ BOTTOM OF SWALE - 3/4" - 1 112" STONE; 0 BOTTOM OF BED EL=4.0± O 10 20 30 40 A 'Al CROSS SECTION A -'A': HORIZONTAL SCALE I "= 10' VERTICAL SCALE I`= 10' Utility Pole #4 BENCHMARK: 4, 189. I ro-:66A 055 p O Q D Top of Water Gate X 100=22.4% M I\ r\ EL=5.6± (MSL 1929 NGVD Datum) 8,73 1 5' LATERAL SOIL REMOVAL (SEE NOTE #I G) INSPECTION PORT �. 5.6 I'ROP05ED SWALE BOTTOM EL=4.8± Q ,�. 48.24 •••• CJ^ V iVi VIVA VI\YV LI -I DRIP LINE i_�--c � �x I _� ,• \ ■ CONCRETE BO ANO 4 ALL AREAS OF THE FRONT PORTION OF THE DWELLING TOP OF BANK , r,. THAT ARE LOCATED WITHIN 20' OF PRIMARY a RESERVE -x-x- LIMIT OF WOP.I V _ _ 5 x5 S.A.S. SHALL BE CONSTRUCTED USING SLAB ON GRADE FENCE Q ti r MTH A MINIMUM SLAB EL= 10.0 13 \\ /` PROPOSED 6" STONE BED @ BOTTOM OF SWALE EDGE OF CLEA PROPO D GAS LINE 6 XW7/ r 9 / 314" 1 1/2" STONE (APPROXI ATE) >r -�' 9 �• i �'"� / - PROPOSED 2' WIDE DRIP LINE TRENCH ON 3:1 SLOPE - 2" OF 1 /8"- 1/2" 5TONI- / J _y': i ,�! " s i !.' Il/f m ry. CONSTRUCT 3 CHECK DAMS TO SLOW RUN-OFF PAULETTE J. FINNERTY REVOCABLE TRUST .e \ PAULETTE J. FINNERTY, TRUSTEE PROPOSED RETAit\JING F \ l 'i + i`y'` " l ( I J - O ,Ai I'ROPCSED WATERLINE CERTIFICATE OF TITLE # 177554 .�,,.. WALL T.O.W. EL=9:0±.U' \ l� .'r �� �I/ l N = ®6A \ (APPROXIMATE) E11Exj5tr,3 rMonitor Well Ha_ ) PARCEL 14VARIE5TOEL-6.0±\p0'B° /i/ 7.a x6.4Zone,y s �/,.r DwellingPROPOSED SWALE G' `9 f2' PROPOSED 2' WIDE DRIP LINE R'dEL=3/4" - I/2" STONE V✓RAPPEDBOTTOM OF SWALE-EL=4.t5± a`>' TRENCH (TYP.)?IN FILTER FABRICNOTE: - PROPOBEDROOM\ _ - DRAINAGEI 1/2 EPROPOSED OUTDOOR SHOWER TO SIT ON STONE TRENCH SHALL BE CENTERED UNDER ALL - r DW�LLI(Jv + 1 I' DEEP 3/4" TO " GRAVEL B D FOR SLAB L GO DRIP EDGE5 AND ALONG THE EDGE OF THE STONE x 6.5POOL DECK. e 40 MIL HDPE LINER b - TYPICAL STONE DRIP LINE TRENCH DETAIL: TOP @EL=9.1± _r - _ PROPOSE[) SWALE BOTTOM @ EL=3.0±'.Area= 1,5 731 t F _. .--- -6 x s.9 ` - BOTTOM OF SWALE EL=4.5± NOT TO SCALE --OOt PROPOSED LANDSCAPE WALL - TOP OF WALL VARIES x 75 20 O ED ; 50 0vffer 5x9 EL=6.0± e�9 xF : STONEPOOL Zone '✓ /k # t PROPOSED UMITIO WORK c EL.= 13.0 _' x 6.3 (SEE CONSERVATION NOTE # I) 5 PETER F. 5ARTHOU fi \ '� ft.fy, ij / t °' Q tic/ * 35, gvffer MIMI SATNOUEL=5.55 \ Zone xZOLANDCOURT DOCUMENT#118351 x74CALCULATIONS: PARCEL 116 INFILTRATION RATE: 0.9 GAUSF/MIN (SAND) / BACKWASH BED: 32'x 12'x 1 8" \ POOL 5x9 (EL= 13.0-) + 22" SURFACE AREA: [2(1 2 x 1.5) + 2(32 x 1.5) + (32 x 1 .5)]=516 5F 90 INFILTRATION CAPACITY: 516 SF x (0.9 GAUSF/MIN) x/. - \. ``' x 6.9 / (18". Effective =464 GAUMIN - / / \ _ f O d, Depth) - BACKWASH FILTER TO BE LIMITED TO 100 GAUMIN * J �.7 /� �¢° VOLUME: 32 x 12 x 1.5=57G CF x \ x 7,3 / \ U' • ro f: t "+/� \� 2 4' 4' 4' EL=3.75 576 x 45%=259 CF - 1 930 GAL �� \ / / • r � O�'�P ` 5x ' i OvFfer x7.1 1* PR SED +� � I i 4 9..i� PROPOSED POOL f�lone * A N <,t "` Mky � I EL=2.75 (GROUND WATER) i BACKWASH 0 ISEE DETAIL) �, " )� T " +� SO t oa ". D,aeNn9 i / 9.0 x �9eETZZ6e;.'r \,r +� / hL NOTE: )� CONSTRUCT BY FACING THREE (3) - 8' x 4' FLOW DIFFUSERS (USE FD 4'x 8'- D FLOW DIFFUSER UNITS BY SHOREY PRECAST, INC.) WITH 4' " SOP # I SOP #2 OF STONE AROUf D AND G" OF STONE BELOW - I x 5 a ` / * xT % q \ \ 3 00 �A �- / •�Ir' DEP OBSERVATION BACKWASH BED DETAIL: ,/ 9.4 /x�x / DEP OBSERVA Jj 9 1 f// PLOT #2 PLOT #y C NOT TO SCALE PROPOSED SWALE J(3.1 ! BOTTOM / x 5.4 INSPECTION NOTE: // x 62, co PROPOSED LIMIT b �. / • - 3.4 - r PRIOR TO FR•IAL INSPECTION BY THE ENGINEER, SYSTEM OF WORK NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS. o Proposed EL= I I .O± Proposed EL=9.8± Min. INSPECTION PORT ©___ --x 6.00 x 4.4 100 YR FLOOD PLAIN ZONE: A 12 ELEVATION= 10 FROM FEMA MAPS COMMUNITY PANEL #250015 0005D JULY 2, 1992 AREA ISN IN A VELOCITY ZONE___ VARIANCE REQUEST: SECTION 3.7 DISTANCE * LOCATION OF DISPOSAL FACILITIES • SPECIFICALLY: THE REQUIREMENT OF "NO FILL SHALL BE DEPOSITED WHEN THE WATER TABLE 15 WITHIN FOUR (4) FEET OF THE ORIGINAL GRADE • PROJECT 15 PROPOSING TO MOUND THE SEWAGE SYSTEM 50 AS TO MAINTAIN THE FIVE (5) FEET OF SEPARATION ABOVE GROUNDWATER TO THE BOTTOM OF THE S.A.5. OF Asq, JOHN M. 10.65± 9" Cover Min. i / All x ss a.o 99'I�LI Lj _� 4 n „ ii JOSEPH H. PETROV✓SKI d � �' - Vegetated Revised 05/131) O: Revi 2 LAYER OF 1/8 - 1/2 STONE Wetland CAP DEBRA T. PETROWSK4. 3.9 alb PLAN I 925 LAND. COURT DOCUMENT #54305) I �/. �I L 8.55 G„ 3/4 1-1 /2" STONE PARCEL 121®- - _ SCALE I "=20' c/o Gregg Usclott 5.79 8.62 7.85 8.35 6 / ,1, TI1 YTOWN WATERREA 15 ED SITE * SEW 2 DROP 34 3I � LEACHING FIELD 5.1' Aif 45.0'x I5.0'xG.O" J.M. Loncge5tRun = 8'± Proft •I'--44'± 7- EL= 2.75 HIGH GROUNDWATER 0 D��Btt-3 0 20 40 GO D -LJ OX SCALE 1"=20' (508)896-6601 h r ATE: H 20GAAAJobsbsootti Development\Mo55Roac1127GA\dwg\127GA.SD5.rev5-13-10.dwg 04/21/10 Yarmouth Conservation Commission MAY 14 2010 RECEIVED t,A,`AAA., $N 0� f R` JOHN ta. O'REILLY NO. 4e733