HomeMy WebLinkAbout83-1885m ' n D Z I CATCH BASIN RIM=6.2 TOP OF FOUNDATION EL - 100 FINISH GRADE ^_ 20 10 0 PLAN 20 1 inch = 20 fL MANHOLE AND COVER -MIN 24' DIA RAISE COVERS TO MTIdN B' OF FINISH GRADE .i I/A UNIT sD 4.5 o 0 4.25 • 4.0 4.0 6' OF 3/4' TO 1-1/2DIA. STOW BELOW TANK ULTRA -MOLE SEPTIC TANK DISINFECTION UNIT PRECAST REINFORCED CONCRETE NOTE: CAPACITY: 1500 GALLONS ALL PIPE TO BE 4' DIA. (H-20) PVC TIGHT JOINT WTH MINIMUM SLOPE OF 1/8 - PER FT CONSERVATION NO TES 1. THE WORK AREA SHALL BE DESIGNATED WITH A WORK LIMIT INSTALLED AS SPECIFIED BY THE YARMOUTH CONSERVATION COMMISSION WHERE SHOWN. THE WORK LiMFF SHALL REMAIN IN PLACE UNTIL THE WORK IS COMPLETE AND THE AREA CLEARED OF MINOR DEBRIS WITH FULL GROUND COVER RESTORATION. 2. NO CONSTRUCTION WORK-RELATED ACTIVITY SHALL OCCUR BEYOND THE WORK LiMIT. 3. ACCESS TO THE WORK SiTE SHALL BE VIA THE STREET AND PROPOSED DRIVEWAY �W AREA. 4. ALL PRUNED BRANCHES, VINES AND! OR ROOTS AND SLASH SHALL BE REMOVED "t APPLICADLF COASTAL FLOOD iS ZONE. A4 W/ RFE -5 NGVD AS SHOWN FROM THE PROPERTY. ON F.f.R.M. PANEI, 2500150002D, 11.Ar REV. JULY 2,1992 5, THE SITE SHALL BE RESTORED TO A THICKLY VEGETATED CONDITION WITHIN THE C / 1 50 FT. BUFFER BY THE PLANTING ABUNDANT NATIVE SHRUBS. A LANDSCAPE PLAN CAN BE MADE AVAILABLE TO DEMONSTRATE THE MITIGATION PORTION OF THE PROJECT.. ? ➢'' "2r 6. ALL WORK SHALL BE IN ACCORDANCE WITH TITLE 5 AND TOWN OF YARMOUTH HEALTH CODE AND CONSERVATION COMMISSION REQUIREMENTS. 17g STEPS 7. CONTRACTOR IS REMINDED TO REFER TO THE ORDER OF CONDITIONS ISSUED FOR j' THE WORK ACTIVITY BY THE YARMOUTH CONSERVATION COMMISSION. G� VALVE VE FOLLINS POND (TIDAL) FlNISH 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE CATCH BASIN RIM WHERE SHOWN. CONTACT CAPE COD ENGINEERING, INC. FOR ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY °REPARED BY SCHOFIELD BROTHERS OF CAPE COD, INC.; ROBERT FREEMAN, PLS; MARCH. 11, 2010 AND PLAIN BOOK 179, PAGE 49 LOT 11 3. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO THE STATE SANITARY CODE, 77TLE 5 AND TOWN OF YARMOUTH HEALTH BOARD APPROVAL FOR THE DESIGN. 4. PERCOLATION TESTS SHALL BE PERFORMED TO VERIFY A 5 MPI OR FASTER PERCOLATION RATE USING A DEWATERING PROCESS PRIOR TO BUILDING PERMIT APPROVAL AND CONSTRUCTION APPROVAL FOR THE NEW SYSTEM. 5. INSTALLATION CONTRACTOR SHALL VERIFY THE SEPTIC SOIL PIPE CONDITION AT THE FOUNDATION AS SET BY THE PLUMBER PRIOR TO MAKING CONNECTION TO THE NEW SEPTIC TANK. 6. A 5 FT. PERIMETER EXCAVATION IS REQUIRED TO REMOVE THE SURFACE SOILS AND OTHER UNSUITABLE SOIL SOIL TESTS INDICATE A DEPTH OF REMOVAL IS APPROXIMATELY 7 FT. BACK FI,L WITH CLEAN SAND MEETING TITLE 5 SPECIFICATIONS FOR FILL CONSTRUCT THE SAS IN THE NEWMATERIAL 7. INSTALLER SHALL CONTACT ENGiNF.F,R AT TIME OF SYSTEM COMPLETION FOR SYSTEM CERTIFICATION AS REQUIRED. S. CONTACT ENGINEER iF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOIL CONDITIONS ENCOUNTERED DURING CONSTRUCTION. 9. NO KNOWN WELLS EXIST WITHIN 200 FT. OF THE PROPOSED SEPTIC SYSTEM OTHER TILAN THOSE SHOWN. 10. DRIVEWAY SHALL BE OF SEMI -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN FOR SITE RESTORATIPON 1 MITIGATION PLANS. DESIGN DATA HYDRAULIC LOADING - 3 BEDROOMS X I IQGPD1BR = 330.0 GPD SEPTIC TANK DESIGN 200%. X 330 GAL - 660 GAL - PROVIDE 1500 GALLON TANK UNIT SIZED FOR SINGULAIR BiO-KINETIC WASTEWATER TREATMENT SYSTEM. OBTAIN SYSTEM SUPPLIER 0 & M CONTRACT PRIOR TO CONSTRUCTION APPLICATION. SUPPLY EQUIVALENT TECHNOLOGY ONLY LION ENGINEER AND HEALTH DEPT. AUTHORIZATION SAS DESIGN PERCOLATION RATE - LESS TIA.N 5 WI'1 LONG TERM HYDRAULIC LOAD RATE - 0.74 GAUS.F. SIDEWALL AREA: NOT APPLICABLE WITH BED -TYPE SAS BOTTOM AREA = 40'X I1S' = 460.0 S.F. LOADING: (460 S.F.) 0.74 GALiSFJDAY - 340.4 CPD TOTAL LEACHING CAPACITY - 340.4 CPD PROVIDE BED - TYPE SAS, 40 FT. LONG X 11.5 FF. WIDE W/ 6INCH EFFECTIVE DEPTH RESERVE AREA = 50'X 9'= 450 S.F. REQUIRES TANK AND P.C. RELOCATION *THF, DESIGN IS NOT SUITABLE FOR USE WITH A GARBAGE DISPOSAL UNIT MEEROX NSIO IMNS 2' LATER OF 1/4' TO 3/4' OIA PEASTOW \ PIPE POPE 0.5% BOTTWJ EL. 'T.O w zTo S•A•S• I� R OF � n BASE -- ----I N1SNN COMPACTED "BOX PROPOSED CONTOUR EXISTING CONTOUR LiR1L(5) EIOTNG D -BOX MUST WATER LINE REMAIN LEVEL FOR T'-0- OVERHEAD WIRES TOOOWN TO BEFORE RHMG N I ' ENQNEER FOR WENT LAYOUT SEPTIC SYSTEM PROFILE PROPOSED S.A.S NO SCALE PROPOSED RESERVE AREA m� zo I PROPOSED PUMP CHAMBER EXISTING SPOT GRADE 0 PROPOSED SPOT GRADE TEST HOLE LOCATION VALVE VE FOLLINS POND (TIDAL) FlNISH 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE CATCH BASIN RIM WHERE SHOWN. CONTACT CAPE COD ENGINEERING, INC. FOR ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY °REPARED BY SCHOFIELD BROTHERS OF CAPE COD, INC.; ROBERT FREEMAN, PLS; MARCH. 11, 2010 AND PLAIN BOOK 179, PAGE 49 LOT 11 3. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO THE STATE SANITARY CODE, 77TLE 5 AND TOWN OF YARMOUTH HEALTH BOARD APPROVAL FOR THE DESIGN. 4. PERCOLATION TESTS SHALL BE PERFORMED TO VERIFY A 5 MPI OR FASTER PERCOLATION RATE USING A DEWATERING PROCESS PRIOR TO BUILDING PERMIT APPROVAL AND CONSTRUCTION APPROVAL FOR THE NEW SYSTEM. 5. INSTALLATION CONTRACTOR SHALL VERIFY THE SEPTIC SOIL PIPE CONDITION AT THE FOUNDATION AS SET BY THE PLUMBER PRIOR TO MAKING CONNECTION TO THE NEW SEPTIC TANK. 6. A 5 FT. PERIMETER EXCAVATION IS REQUIRED TO REMOVE THE SURFACE SOILS AND OTHER UNSUITABLE SOIL SOIL TESTS INDICATE A DEPTH OF REMOVAL IS APPROXIMATELY 7 FT. BACK FI,L WITH CLEAN SAND MEETING TITLE 5 SPECIFICATIONS FOR FILL CONSTRUCT THE SAS IN THE NEWMATERIAL 7. INSTALLER SHALL CONTACT ENGiNF.F,R AT TIME OF SYSTEM COMPLETION FOR SYSTEM CERTIFICATION AS REQUIRED. S. CONTACT ENGINEER iF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOIL CONDITIONS ENCOUNTERED DURING CONSTRUCTION. 9. NO KNOWN WELLS EXIST WITHIN 200 FT. OF THE PROPOSED SEPTIC SYSTEM OTHER TILAN THOSE SHOWN. 10. DRIVEWAY SHALL BE OF SEMI -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN FOR SITE RESTORATIPON 1 MITIGATION PLANS. DESIGN DATA HYDRAULIC LOADING - 3 BEDROOMS X I IQGPD1BR = 330.0 GPD SEPTIC TANK DESIGN 200%. X 330 GAL - 660 GAL - PROVIDE 1500 GALLON TANK UNIT SIZED FOR SINGULAIR BiO-KINETIC WASTEWATER TREATMENT SYSTEM. OBTAIN SYSTEM SUPPLIER 0 & M CONTRACT PRIOR TO CONSTRUCTION APPLICATION. SUPPLY EQUIVALENT TECHNOLOGY ONLY LION ENGINEER AND HEALTH DEPT. AUTHORIZATION SAS DESIGN PERCOLATION RATE - LESS TIA.N 5 WI'1 LONG TERM HYDRAULIC LOAD RATE - 0.74 GAUS.F. SIDEWALL AREA: NOT APPLICABLE WITH BED -TYPE SAS BOTTOM AREA = 40'X I1S' = 460.0 S.F. LOADING: (460 S.F.) 0.74 GALiSFJDAY - 340.4 CPD TOTAL LEACHING CAPACITY - 340.4 CPD PROVIDE BED - TYPE SAS, 40 FT. LONG X 11.5 FF. WIDE W/ 6INCH EFFECTIVE DEPTH RESERVE AREA = 50'X 9'= 450 S.F. REQUIRES TANK AND P.C. RELOCATION *THF, DESIGN IS NOT SUITABLE FOR USE WITH A GARBAGE DISPOSAL UNIT MEEROX NSIO IMNS 2' LATER OF 1/4' TO 3/4' OIA PEASTOW \ PIPE POPE 0.5% BOTTWJ EL. 'T.O w zTo S•A•S• I� R OF � n BASE -- ----I N1SNN 3/4' TO 1-1/2' DIA, DOUBLE -WASHED NATIVE STONE RJ BED NNYLCONCRETE """'-'-•--- 701Ma BARRIERIER WALL WALL +/ STONE FACE DIA. PERF. PVC PIPE ROAD 411 0- sETucys, 9 U i r, MERCHANTS FOLLWS AVE POND LOCUS YARMOUTH, MA KEY MAP NO SCALE LEGEND COMPACTED "BOX PROPOSED CONTOUR EXISTING CONTOUR LiR1L(5) EIOTNG D -BOX MUST WATER LINE REMAIN LEVEL FOR T'-0- OVERHEAD WIRES TOOOWN TO BEFORE RHMG PUMP CHAMBER - A CONTRACTOR SHALL CONTACT LEACHNG FACttJn SEE SPEC19CATIONS ENQNEER FOR WENT LAYOUT SEPTIC SYSTEM PROFILE PROPOSED S.A.S NO SCALE 3/4' TO 1-1/2' DIA, DOUBLE -WASHED NATIVE STONE RJ BED NNYLCONCRETE """'-'-•--- 701Ma BARRIERIER WALL WALL +/ STONE FACE DIA. PERF. PVC PIPE ROAD 411 0- sETucys, 9 U i r, MERCHANTS FOLLWS AVE POND LOCUS YARMOUTH, MA KEY MAP NO SCALE LEGEND --M- PROPOSED CONTOUR EXISTING CONTOUR W WATER LINE OVERHEAD WIRES DRAIN LUNE P-0 zi PROPOSED 1500 GAL SEPTIC TANK ET PROPOSED DIS19BUIlON BOX ® PROPOSED S.A.S PROPOSED RESERVE AREA O PROPOSED PUMP CHAMBER EXISTING SPOT GRADE 1® PROPOSED SPOT GRADE TEST HOLE LOCATION GROUNDWATER NOTE GROUNDWATER ELEVATION HAS BEEN DETERMINED BY FRIMPTER METHOD. APRIL 28 SOIL TESTS FOUND GROUNDWATER ELEV. - 0.75 RESTRICTED BY SUBSURFACE PEAT; FRIMPTER ADJUSTMENT OF 03 FT. ADJ. HIGH GROUNDWATER ELEV, = L1(USE ELEV. - 2.0 FOR DESIGN) e RiiViSr'D AUGUST 20. 2010 - FLOW) 7.ON1: NO"I AT10N TOPOGRAPHIC SITE MAN SHOWING 1 PROPOSED CONSTRUCTION OF A SINGLE FAMILY DWELLING AND SUBSURFACE SEWAGE DISPOSAL SYSTEM AT 79 MERCHANT AVENUE, YARMOUTHPORT, MA ASSESSORS MAP 127, PARCEL 33 PREPARED FOR SUSANNE McINERNEY AUGUST 18, 2010 SCALE - AS NOTED PREPARED BY CAPE COD ENGINEERING, INC. ROBERT M. PERRY, P.E. P.O. BOX 1517 EAST DENNIS, MA 02641 SOU I R ES. D WG 508-385-1445 TOP OF FOUNDATION EL - 10.0 FINISH GRADE J.0 T 6. OF 1/4' TO L--- 1-1/7 DIA STCNE� ` BELOW TANK NOTE: ALL PIPE TO BE 4' DIA. PVC TIGHT JOINT NTH MINIMUM SLOPE OF 1/8' PER FT. CATCH BASIN RIM=6.2 loif> I/A UNIT SEP11C TANK PRECAST REINFORCED CONCRETE CAPACITY: 1500 GALLONS (H-20) CONSERVATION NOTES EXISTING DWELLING 1. THE WORK AREA SHALL BE DESIGNATED WFFH A WORK LtWT LNSTALLED AS SPECIFIED BY THE YARMOUTH CONSERVATION COMMISSION WHERE SHOWN. THE f WORK LIMIT SHALL REMAIN IN PLACE UNIT. THE WORK IS COMPLETE AND THE AREA CLEARED OF MINOR DEBRIS WITH FULL GROUND COVER RESTORATION. x9.8 2. NO CONSTRLTCTION WORK-RELATED ACTIVITY SHALL OCCUR BEYOND THE WORK LIMIT. 3. ACCESS TO THE WORK SITE. SHALL BE VIA THE STREET AND PROPOSED DRIVEWAY _ AREA. ?� APPLICABLE COASTAL FLOOD IS ZONE A4 W/ AFF!- 5 NC VD AS SHOWN 4. ALL PRUNED BRANM VINES AND IOR ROOTS AND SLASH SHALL BE REMOVED /f� R. ON F.I.M. PANEL 2500150002D, MAP REV. JULY 2, 1992 FROM THF. PROPERTY" 5. THE SITE SHALL BE RESTORED TO A THICKLY VEGETATED CONDITION WITHIN T19E 50 FT. BUFFER BY THE PLANTING ABUNDANT NATIVE SHRUBS. A LANDSCAPE PLAN CAN BE MADE AVAILABLE TO DEMONSTRATE THE MITIGATION PORTION OF THE r PROJECT. l m / C ALL WORK SHALL BE N ACCORDANCE WITH TFFLE 5 AND TOWN OF YARMOUTH 1 HEALTH CODE AND CONSERVATION COMMISSION REQUIREMENTS. STEPS 7. CONTRACTOR IS REMINDED TO REFER TO THE ORDER OF CONDITIONS ISSUED FOR THE WORK ACTIVITY BY THE YARMOUTH CONSERVATION COMMISSION. 0 GENTRALNOTES n 4"�U 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE CATCH A �`Qc Bim/ f} , 2 T BASIN RIM WHERE SHOWN. CONTACT CAPE COD ENGINEERING, INC. POR b 1 ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY °REPARED BY SCHOFIELD jj BROTHERS OF CAPE COD, INC.; ROBERT FREEMAN, PLS; MARCH. 11, 2010 ANTI PLAN BOOK 179, PAGE 49 LOT 11. CM 6 3. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL f! X5: Akti I, v.. x _ C 3 CONFORM TO THE STATE SANITARY CODE, TITLE 5 AND TOWN OF YARMOUTH / J/: / ! REALM BOARD APPROVAL FOR THE DESIGN. r / 4. PERCOLATION TESTS SHALL BE PERFORMED TO VERIFY A 5 MPI OR FASTER K r PERCOLATION RATE USING A DEWATERUVG PROCESS PRIOR TO BUHIILNG gpj .f f ¢ ` FO LLl N S POND PERMIT APPROVAL AND CONSTRUCTION APPROVAL FOR THE NEW SYSTEM. �I m .: h TIDAL 5. INSTALLATION CONTRACTOR SHALL VERIFY THE SEPTIC SOIL PIPE CONDMON 7 AT THE FOUNDATION AS SET BY THE PLUMBER PRIOR TO MAKING CONNECTION TO THE NEW SEPTIC TAPIK. _,. _ 6. A S FT. PEIHDLETER EXCAVATION IS REQUIRED TO REMOVE THE SURFACE SOILS 00' FROM TOP OF BA ItzAND OTHER UNSUITABLE SOIL SOIL TESTS INDICATE A DEPTH OF REMOVAL IS APPROXiNATELY 7 FT. BACKFILL WITH CLEAN SAND MEETING TITLE 5 I SPECIFICATIONS FOR FILL CONSTRUCT THE SAS IN THE NEW MATERIAL. 7. INSTALLER SHALL CONTACT ENGINEER AT TIME OF SYSTEM COMPLETION FOR S,] SYSTEM CERTIFICATION AS REQUIRED. T SiNCKEt ROAD BOJ o z MERCHANTS FOLLINS .AVE POND LOCUS YARMOUTH, MA 1 KEY MAP NO SCALE LEGEND IL_ PROPOSED CONTOUR L CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOH, EXISTING CONTOUR WATER UNE f OVERHEAD DETERMINED BY FREWTER METHOD. DRAIN "0 PROPOSED 1500 GAL SEPTIC TANK APRIL 28 SOIL TESTS FOUND PROPOSED DISTRIBUTION :. BONN LEVEL FOR 7-O' PROPOSED GROUNDWATER ELEV. - 0.75 ..POSEDER a PROP,.,, PUM'. • CHAMBER 10. DRIVEWAY SHALL BE OF SEMI -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN EXISTING,SPOT GRADE ?iE3! ..POSE, SPOT GRADE FOR SITE RFSTORATIPOY! MITIGATION PLANS. TEST HOLE LOCATION PLAN 20 I inch c 20 it. MANHOLE AND COVER -MN 24' DIA. RAISE COVERS TO WITHIN 6' OF FINISH GRADE I 415 J.9� a 14D H, .r CHECNVALVE iGAIE VALVE � � FINISH PEMIIM D- 90 SIME DE CNSOVS 2' NOF STO TO !-x17 J/4'- DIA. A. PEASIONE \ b I IL_ 4 L CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOH, GROUNDWATER ELEVATION HAS BEEN f CONDITIONS ENCOUNTERED DURING CO`TS1?:L'CT!0N. DETERMINED BY FREWTER METHOD. .I J - 9. NO KNOWN WELLS EXIST WITHIN, 200 FT. OF THE PROPOSED SEPTIC SYSTEM APRIL 28 SOIL TESTS FOUND BONN LEVEL FOR 7-O' OTHER THAN THOSE SHOWN. GROUNDWATER ELEV. - 0.75 SEE SPECIFICATIONS i CONTRACTOR SHALL CONTACT IEACHNG FACRITY ENGINEER FOR WNT ural ( 10. DRIVEWAY SHALL BE OF SEMI -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN RESTRICTED BY SUBSURFACE PEAT; 1!g I FOR SITE RFSTORATIPOY! MITIGATION PLANS. FREHPIER ADJUSTMENT OF 03 FT. ADJ. HIGH GROUNDWATER ELEV. -1.1(USE DESIGN DATA ELEV. n2.0FOR DESIGN) HYDRAULIC LOADING - 3 BEDROOMS X 110GPDBR = 330.0 GPD SEPTIC TANK DESIGN PLAN 20 I inch c 20 it. MANHOLE AND COVER -MN 24' DIA. RAISE COVERS TO WITHIN 6' OF FINISH GRADE I 415 J.9� a 14D H, .r CHECNVALVE iGAIE VALVE � � FINISH PEMIIM D- 90 SIME DE CNSOVS 2' NOF STO TO !-x17 J/4'- DIA. A. PEASIONE \ b I IL_ a� _- PIPES 7.0 770 :o .I C BASE D -BOX 1 / 6' LED OF UNE(S) EXFING 0 --BOX MUST WCRUSHFO STONE - UNNE( BONN LEVEL FOR 7-O' PUMP CHAMBER ! BEFORE PITCHING DOWN TO SEE SPECIFICATIONS i CONTRACTOR SHALL CONTACT IEACHNG FACRITY ENGINEER FOR WNT ural SEPTIC SYSTEM PROFILE NO SCALE 3/4' TO 1-1/2' OA' DOUBLE -WASHED NATIVE STONE N BED PIPE SLOPE 0.55 40' &L& S.A.S, CROSS SECTION NO SCALE 200%* X 330 GAL - 660 GAL - PROVIDE 1500 GALLON TANK UNIT SIZED FOR SINGUl" BIO -KINETIC WASTEWATER TREATMENT SYSTEM. OBTAIN SYSTEM SUPPLIER 0 do M CONTRACT PRIOR TO CONSTRUCTION APPLICATION. SUPPLY EQUIVALF,IIT TECHNOLOGY ONLY UPON ENGINEER AND HEALTH DEFT. AUTHORIZATION SAS DESIGN PERCOLATION RATE - LESS THAN 5 MPI LONG TERM HYDRAULIC LOAD RATE - 0.74 GAIAF. SIDEWALL AREA: NOT APPLICABLE WITH BED -TYPE SAS A BOTTOM AREA - 40'X I IN = 460.0 S.F. � LOADING: (460 S.F.) 0.74 GALSFJDAY - 340.4 GPD TOTAL LEACHING CAPACITY - 340A GPD PROVIDE BED • TYPE SAS, 40 FT. LONG X 11.5 FT. WIDE W/ 6 INCH EFFECTDEPTH i 'V $' PVE RESERVE AREA = 50'X 9'= 450 S.F. REQUIRES TANK AND P.C. RELOCATION 3 N *TRF. DESIGN IS NOT SUITABLE, FOR USE WITH A GARBAGE UNITISPOSAL UA J .• c REVISED AUGUST 20,20 ZONE NOTATION TOPOGRAPHIC SItE PLAN SHOWING PROPOSED CONSTRUCTION OF A SINGLE FAMILY DWELLING AND SUBSURFACE SEWAGE DISPOSAL SYSTEM AT BOTTOM u..70 79 MERCHANT AVENUE, YARMOUTHPORT, MA ASSESSORS MAP 127, PARCEL 33 PREPARED FOR SUSANNE MCINERNEY MR1.-BACKED CONCRETE roWas FA�'ER WALL'/ STONEAUGUST 18, 2010 SCALE - AS NOTED aA PERF M PIPE _ PREPARED BY - CAPE COD ENGINEERING, INC. ROBERT M. PERRY, P.E. P.O. BOX 1517 EAST DENNIS, MA 02641 SOUIRES.DWG 508-385-1445 CATCH BASIN M REPLACED •/ SOLD DIA. It 3A H BASIN CATCH RIM=6 2 TOP OF FOUNDATION EL - 10.0 1`11,491 GRADE I= rri """LWATER GATE E r Z 111 15 O t , PROPOSED 1 jO I r PERVIOUS R I DRIVEWA iCATCH I 1 BASIN RIM=6.1 I INV=4. L 1 70' FROM TOP of i I J ✓ L N�� i EXISTING DWELLING ,C G PLAN 10 0 20 1 inch - 20 fM- MANHOLE AND COVER-M!N 24' DIA. RAISE COVERS TO WTHIN 6' OF FINI91 GRADE v I/A UNIT so T 4 25 45 � �� 40 ,•� s.0 6- OF 3/4' TO - --- --- 1-1/2• DIA. STONE. t' BELOW TANK ULTRA -HOLE SEPTIC TANK DISINFECTION UNIT PRECAST REINFORCED CONCRETE NOTE. CAPACITY: 1500 GALLONS ALL PIPE TO BE C DIA. (H-20) PVC TIGHT JOINT WTH MINIMUM SLOPE OF 1/8' PER FT. OF 178 f I II � 1. THE WORK AREA SHALL BE DESIGNATED WITH A WORK LIMIT INSTALLED AS SPECIFIED BY THE YARMOUTH CONSERVATION COMMISSION WHERE SHOWN. THE WORK LLNUT SHALL REMAIN IN PLACE UNTIL THE WORK IS COMPLETE AND THE AREA CLEARED OF MINOR DEBRIS WITH FULL GROUND COVER RESTORATION. 2. NO CONSTRUCTION WORK-RELATED ACTIVITY SHALL OCCUR BEYOND THE WORK LIMIT. 3. ACCESS TO THE WORK SITE SHALL BE VIA THE STREET AND PROPOSED DRIVEWAY AREA. 4. ALL PRUNED BRANCHES, VINES AND / OR ROOTS AND SLASH SHALL BE REMOVED FROM THE PROPERTY. 5. THE SITE SHALL BE RESTORED TO A THICKLY VEGETATED CONDITION WITHIN THE 50 FT. BUFFER BY THE PLANTING ABUNDANT NATIVE SHRUBS. A LANDSCAPE PLAN CAN BE MADE AVAILABLE TO DEMONSTRATE THE MITIGATION PORTION OF THE PROJECT. 6. ALL WORK SHALL BE IN ACCORDANCE WITH TITLE 5 AND TOWN OF YARMOUTH HEALTH CODE AND CONSERVATION CO -MMI BION REQUIREMENTS. 7, CONTRACTOR IS REMINDED TO REFER TO THE ORDER OF CONDITIONS ISSUED FOR THE WORK ACTIVITY BY THE YARMOUTH CONSERVATION COMMISSION. GENERAL NOTES �o 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE CATCH BASIN RAI RTIERE SHOWN. CONTACT CAPE COD ENGINEERING, INC. FOR 70PQe B / f-� ,v ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY PREPARED BY SCHOFIELD { BROTHERS OF CAPE COD, INC.; ROBERT FREEMAN, PIS; MARCH. 11, 2010 AND PLAN BOOK 179, PAGE 49 LOT 11 8' CORRUGATE PIPE INV=3.3 W 3. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL t5 CONFORM TO THE STATE SANITARY CODE, TITLE 5 AND TOWN OF YARMOUTH S / HEALTH BOARD APPROVAL FOR THE DESIGN. = 4. PERCOLATION TESTS SHALL BE PERFORMED TO VERIFY A 5 MPI OR FASTER > '` I =`"• cc PERCOLATION RATE USING A DEWATERING PROCESS PRIOR TO BUILDING FO L LI N S POND PERMIT APPROVAL AND CONSTRUCTION APPROVAL FOR THE NEW SYSTEM. r 5. INSTALLATION CONTRACTOR SHALL VERIFY THE SEPTIC SOIL PIPE CONDITION (TIDAL) AT THE FOUND I,TION AS SET BY THE PLUMBER PRIOR TO MAKING io CONNECTION TO THE NEW SEPTIC TANK 6. A S FT. PERIMETER EXCAVATION IS REQUIRED TO REMOVE THE SURFACE SOUS k AND OTHER UNSUITABLE SOIL. SOIL TESTS INDICATE A DEPTH OF REMOVAL IS m APPROXIMATELY 7 FT. BACK FILL WITH CLEAN SAND MEETING TITLE 5 • I SPECIFICATIONS FOR FILL CONSTRUCT THE SAS IN THE NEW MATERIAL. y% \ 7. INSTALLER SHALL CONTACT ENGINEER AT TIME OF SYSTEM COMPLETION FOR SYSTEM CERTIFICATION AS REQUIRED. 8. CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOIL ` I CONDITIONS ENCOUNTERED DURING CONSTRUCTION, ` 9. NO KNOWNWELLS EXIST WITHIN 200 FT. OF THE PROPOSED SEPTIC SYSTEM t, OTHER THAN THOSE SHOWN. 10.DRIVEWAY SHALL BE OF SETH -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN FOR SITE RESTORATIPON / MITIGATION PLANS. DESIGN DATA � `Ts HYDRAULIC LOADING - 3 BEDROOMS X 110GPD/BR = 330.0 CPD SEPTIC TANK DESIGN 200% X 330 GAL = 660 GAL. - PROVIDE 1500 GALLON TANK UNIT SIZED FOR SINGULAIR BIO -KINETIC WASTEWATER TREATMENT SYSTEM. OBTAIN SYSTEM i DEEP OBSERVATION HOLE 01 SUPPLIER 0 & M CONTRACT PRIOR TO CONSTRUCTION APPLICATION. SUPPLY Sl Trot Date: April 28, 2010;EQUIVALENT TECHNOLOGY ONLY UPON ENGINEER AND HEALTH DEPT. P ' Njitness: AMY VONIIONE, RS, YAR1fOVTll HEALTH DEPT. AUTHORIZATION P RFORSfED BY Robert M. Perry, P.E. elevation depth (in.) } } texture color mottling V 11 7-0-6.7 0.9 A r-: IO YR 311( PROPOSED 1500 GAL SEPTIC TANK Fill 178 t \STEPS 9-26 1 � ' 10 YR116 VO Fill 4.9-2.4 26.55 CI Sand. loam 10 SR 6/ 1. THE WORK AREA SHALL BE DESIGNATED WITH A WORK LIMIT INSTALLED AS SPECIFIED BY THE YARMOUTH CONSERVATION COMMISSION WHERE SHOWN. THE WORK LLNUT SHALL REMAIN IN PLACE UNTIL THE WORK IS COMPLETE AND THE AREA CLEARED OF MINOR DEBRIS WITH FULL GROUND COVER RESTORATION. 2. NO CONSTRUCTION WORK-RELATED ACTIVITY SHALL OCCUR BEYOND THE WORK LIMIT. 3. ACCESS TO THE WORK SITE SHALL BE VIA THE STREET AND PROPOSED DRIVEWAY AREA. 4. ALL PRUNED BRANCHES, VINES AND / OR ROOTS AND SLASH SHALL BE REMOVED FROM THE PROPERTY. 5. THE SITE SHALL BE RESTORED TO A THICKLY VEGETATED CONDITION WITHIN THE 50 FT. BUFFER BY THE PLANTING ABUNDANT NATIVE SHRUBS. A LANDSCAPE PLAN CAN BE MADE AVAILABLE TO DEMONSTRATE THE MITIGATION PORTION OF THE PROJECT. 6. ALL WORK SHALL BE IN ACCORDANCE WITH TITLE 5 AND TOWN OF YARMOUTH HEALTH CODE AND CONSERVATION CO -MMI BION REQUIREMENTS. 7, CONTRACTOR IS REMINDED TO REFER TO THE ORDER OF CONDITIONS ISSUED FOR THE WORK ACTIVITY BY THE YARMOUTH CONSERVATION COMMISSION. GENERAL NOTES �o 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE CATCH BASIN RAI RTIERE SHOWN. CONTACT CAPE COD ENGINEERING, INC. FOR 70PQe B / f-� ,v ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY PREPARED BY SCHOFIELD { BROTHERS OF CAPE COD, INC.; ROBERT FREEMAN, PIS; MARCH. 11, 2010 AND PLAN BOOK 179, PAGE 49 LOT 11 8' CORRUGATE PIPE INV=3.3 W 3. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL t5 CONFORM TO THE STATE SANITARY CODE, TITLE 5 AND TOWN OF YARMOUTH S / HEALTH BOARD APPROVAL FOR THE DESIGN. = 4. PERCOLATION TESTS SHALL BE PERFORMED TO VERIFY A 5 MPI OR FASTER > '` I =`"• cc PERCOLATION RATE USING A DEWATERING PROCESS PRIOR TO BUILDING FO L LI N S POND PERMIT APPROVAL AND CONSTRUCTION APPROVAL FOR THE NEW SYSTEM. r 5. INSTALLATION CONTRACTOR SHALL VERIFY THE SEPTIC SOIL PIPE CONDITION (TIDAL) AT THE FOUND I,TION AS SET BY THE PLUMBER PRIOR TO MAKING io CONNECTION TO THE NEW SEPTIC TANK 6. A S FT. PERIMETER EXCAVATION IS REQUIRED TO REMOVE THE SURFACE SOUS k AND OTHER UNSUITABLE SOIL. SOIL TESTS INDICATE A DEPTH OF REMOVAL IS m APPROXIMATELY 7 FT. BACK FILL WITH CLEAN SAND MEETING TITLE 5 • I SPECIFICATIONS FOR FILL CONSTRUCT THE SAS IN THE NEW MATERIAL. y% \ 7. INSTALLER SHALL CONTACT ENGINEER AT TIME OF SYSTEM COMPLETION FOR SYSTEM CERTIFICATION AS REQUIRED. 8. CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOIL ` I CONDITIONS ENCOUNTERED DURING CONSTRUCTION, ` 9. NO KNOWNWELLS EXIST WITHIN 200 FT. OF THE PROPOSED SEPTIC SYSTEM t, OTHER THAN THOSE SHOWN. 10.DRIVEWAY SHALL BE OF SETH -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN FOR SITE RESTORATIPON / MITIGATION PLANS. DESIGN DATA � `Ts HYDRAULIC LOADING - 3 BEDROOMS X 110GPD/BR = 330.0 CPD SEPTIC TANK DESIGN 200% X 330 GAL = 660 GAL. - PROVIDE 1500 GALLON TANK UNIT SIZED FOR SINGULAIR BIO -KINETIC WASTEWATER TREATMENT SYSTEM. OBTAIN SYSTEM i DEEP OBSERVATION HOLE 01 SUPPLIER 0 & M CONTRACT PRIOR TO CONSTRUCTION APPLICATION. SUPPLY Sl Trot Date: April 28, 2010;EQUIVALENT TECHNOLOGY ONLY UPON ENGINEER AND HEALTH DEPT. P ' Njitness: AMY VONIIONE, RS, YAR1fOVTll HEALTH DEPT. AUTHORIZATION P RFORSfED BY Robert M. Perry, P.E. elevation depth (in.) boriron texture color mottling other 7-0-6.7 0.9 A L.Sand IO YR 311( PROPOSED 1500 GAL SEPTIC TANK Fill 6.7-4.8 9-26 B L. Sand 10 YR116 VO Fill 4.9-2.4 26.55 CI Sand. loam 10 SR 6/ TEST HOLE LOCATION till Fill 2.4 • 0 55. 84 C2 PEAT 10-01 184-96 C3 5ird.sand PERCOLATION RATE - LESS THAN 5 MPI LONG TERM HYDRAULIC LOAD RATE = 0.74 GAL/S.F. SIDEWALL AREA: NOT APPLICABLE RTTH BED -TYPE SAS BOTTOM AREA= 40' X 11.5'= 460.0 S.F. LOADING: (460 S.F.) 0.74 GAIAFJDAY - 340.4 GPD TOTAL LEACHING CAPACITY - 340.4 CPD PROVIDE BED - TYPE SAS, 40 FT. LONG X 11.5 FT. RIDE W/ 6INCH EFFECTIVE DEPTH RESERVE AREA = 50'X 9'= 450 S.F. REQUIRES TANK AND P.C. RELOCATION Parent material: Claeiol Outwash ( Fill to 55 inches) *TILE DESIGN IS NOT SUITABLE FOR USE WITH A GARBAGE DISPOSAL UNFF Depth to Groundwater. 69 inches ( el. = 13) Not percolation tested due to groundwater, assumed ins than 5NIP1 In C3. Future thing shall he by dewatering or other location. ,V SETUC AVE LOCUS KEY MAP NO SCALE FOLLINS I POND YARMOUTH, MA LEGEND PROPOSED CONTOUR EXISTING CONTOUR W WATER LINE OVERHEAD WIRES - DRAIN UNE ao o PROPOSED 1500 GAL SEPTIC TANK is PROPOSED DISTRIBUTION BOX ® PROPOSED S.A.S. PROPOSED RESERVE AREA VO PROPOSED PUMP CHAMBER x5 ,c EXISTING SPOT GRADE ® PROPOSED SPOT GRADE t TEST HOLE LOCATION GROUNDWATER ELEVATION IMS BEEN DETERMINED BY FRIMPTER METHOD. APRIL 28 SOIL TESTS FOUND GROUNDWATER ELEV, - 0.75 RESTRICTED BY SUBSURFACE PEAT; FRIMPTE1 ADJUSTMENT OF 03 FT. ADJ. HIGH GROUNDWATER ELEV. =1,1 ( USE ELEV. = 24 FOR DESIGN) FINISH GRADE TOPOGRAPHIC SITE PLAN SHOWING PROPOSED CONSTRUCTION OF MINIMUM D-909 2 LAYER a V4 ro A SINGLE FAMILY DWELLING INSIDE DIMENSIONS VALVE '' 12•x12' 3/4' DIA. PEASTONE \ AND SUBSURFACE SEWAGE DISPOSAL SYSTEM 1 PIPE SLOPE 0-- BOTTOM EL -7O 79 MERCHANT AVENUE, YAEMOUTHPORT, MA _ - L PIPES 40• ASSESSORS MAP 127, FARCEL 33 900 7,83 7.70 S A•S• PREPARED FCR 3/4- TO 1-I/2• DIA DOUBLE -WASHED SUSANNE McTNERNEY FATIVE STONE N BED COMPACTED BISE N CNE➢ CONE 1/ 6' : APRIER wAu ./ STONE CRUSHED LINE(s) E1anvS D -BOA Musr FCE NOVEMBER 30, 2010 SCALE - AS NOTED REMAIN LEVEL FOP. 2'-0* BEFORE PITCHING DOWN TO f V, b -DIA. PErii PVC PIPEy+y� PREPARED $Y PUMP CHAMBER LEACmNG FAautr ERT 4 CONTRACTOR SMALL CONTACTCAPE COD ENGINEERING, INC. SEE SPECIFICATIONS ENGINEER FOR VERT LAYOUT `-! M. 1 S. PERRY w ROBERT M. PERRY, P.E. C.✓SL SEPTIC SYSTEM PROFILE S.A.S. CROSS SECTION 7 P.O. BOX 1517 NO SCALE NO SCALE \ re¢ EAST DENNIS, MA 02641 SOU I RE S. D WG 508-385-1445 M H BASIN i CATCH EAS'N RIA+=6 2 TnP OF FOUNDAPON ID.0 FINISH GRADE 2 EXISTING DWELLING PLAN 1 inch - 20 fL MAWOLE AND COVER -MN 2e DIA. RAISE COVERS TO WHIN 6' OF FIN:94 GRADE i YY 1A UNIT UNIT ,.5 T 770-s-�� 1.25 O I ,.D:--I .D 6. OF 3/4- TO --7- -- t: 1-1/2' CIA. STONE texture BELOW TANK ULIRLAOLET TANK I other SEPTIC DISINFECTION UNIT PRECAST REINFORCED CONCRETE 0-9 CAPACITY: 1500 GALLONS ALL PPE TO BE 4" DIA. (H-20) PVC TIGHT JOINT WITH Fill MINIMUM SLOPE OF 1/8' 9-26 PER FT. L.Sand 91 FOLLINS POND (TIDAL) ''.I DEEP OBSERVATION HOLE #I Test Date: April 28, 2010; Y�j''itnear. AMY VONHONE, RS, YARMOUTH HEALTH DEPT. PERFORMED BY Robert M. Perry, P.E. elevation depth (in.) horizon texture color mottling I other 7.0--6.7 0-9 A L. Sand IO YR 311 SEE SPECIFICATIONS Fill 6.7-4.8 9-26 B L.Sand 10 YR 5/6 Fill 4.8-2.4 26-55 CI Sand. loam 10 YR 61 Fill 2.4- 0 55- 84 C2 PEAT 0-01 194-96 1 C3 Med. sand Parent material: Glacial Outwash ( Fill to 55 inches) Depth to Groundwater. 69 inch" (el. - 1. - Not percolation tested due to groundwater; assumed I"s than 5MPI In C3. Future testing shall be by de -watering or other location. INSERVATION NOTES 1. THE {YORK AREA SHALL BE DESIGNATED WITH A WORK LIMIT NSTALLED AS SPECIFIED BY THE YARMOUTH CONSERVATION COMMISSION WHERE SHOWN. THE WORK LLNHT SHALL REMAIN IN PLACE UNTIL THE WORK IS COMPLETE AND THE AREA CLEARED OF MINOR DEBRIS WITH FULL GROUND COVER RESTORATION. 2. NO CONSTRUCTION WORK-RELATED ACTIVITY SHALL OCCUR BEYOND THE WORK LEVITT. 3. ACCESS TO THE WORK SITE SHALL BE VIA THE STREET AND PROPOSED DRIVEWAY AREA. 4. ALL PRUNED BRANCHES, VINES AND I OR ROOTS AND SLASH SHALL BE REMOVED FROM THE PROPERTY. 5. THE SITE SHALL BE RESTORED TO A THICKLY VEGETATED CONDITION WITHIN THE 50 FT. BUFFER BY THE PLANTING ABUNDANT NATIVE SHRUBS. A LANDSCAPE PLAN CAN BE MADE AVAILABLE TO DEMONSTRATE THE MITIGATION PORTION OF THE PROJECT. 6. ALL WORK SHALL BE IN ACCORDANCE WITH TITLE 5 AND TOWN OF YARMOUTH HEALTH CODE AND CONSERVATION COMMISSION REQUIREMENTS. 7. CONTRACTOR IS REMINDED TO REFER TO THE ORDER OF CONDITIONS ISSUED FOR THE WORK ACTIVITY BY THE YARMOUTH CONSERVATION COMMISSION. GENERAL NOTES 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE CATCH BASIN RAM WHERE SHOWN. CONTACT CAPE COD ENGINEERING, INC. FOR ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY PREPARED BY SCHOFIELD BROTHERS OF CAPE COD, INC.; ROBERT FREEMAN, PLS; MARCH. 11, 2010 AND PLAN BOOK 179, PAGE 49 LOT 11 3. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO THE STATE SANITARY CODE, TITLE 5 AND TOWN OF YARMOUTH HEALTH BOARD APPROVAL FOR THE DESIGN. 4. PERCOLATION TESTS SHALL BE PERFORMED TO VERIFY A 5 MPI OR FASTER PERCOLATION RATE USING A DEWATERING PROCESS PRIOR TO BUILDING PERMIT APPROVAL AND CONSTRUCTION APPROVAL FOR THE NEW SYSTEM. 5. INSTALLATION CONTRACTOR SHALL VERIFY THE SEPTIC SOIL PIPE CONDITION AT THE FOUND MON AS SET BY THE PLUMBER PRIOR TO MAKING CONNECTION TO THE NEW SEPTIC TANK. 6. A 5 FT. PERIMETER EXCAVATION IS REQUIRED TO REMOVE THE SURFACE SOILS AND OTHER UNSUITABLE SOIL. SOIL TESTS INDICATE A DEPTH OF REMOVAL IS APPROXIMATELY 7 FT. BACK FILL WITH CLEAN SkND MEETING TITLE 5 SPECIFICATIONS FOR FILL, CONSTRUCT THE SAS IN THE NEW MATERIAL. 7. INSTALLER SHALL. CONTACT ENGINEER AT TIME OF SYSTEM COMPLETION FOR SYSTEM CERTIFICATION AS REQUIRED. 8. CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOH, CONDITIONS ENCOUNTERED DURING CONSTRUCTION. 9. NO KNOWN WELLS EXIST VITTHIN 200 FT. OF THE PROPOSED SEPTIC SYSTEM OTHER THAN THOSE SHOWN. 10. DRIVEWAY SHALL BE OF SEMI -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN FOR SITE RESTORATIPON / MITIGATION PLANS. HYDRAULIC LOADING - 3 BEDROOMS X 110GPDBR=330.0 CPD SEPTIC TANK DESIGN 200% X 330 GAL = 660 GAL - PROVIDE 1500 GALLON TANK UNIT SIZED FOR SINGULAIR BIO -KINETIC WASTEWATER TREATMENT SYSTEM. OBTAIN SYSTEM SLTPLIER 0 & M CONTRACT PRIOR TO CONSTRUCTION APPLICATION. SUPPLY EQUIVALENT TECHNOLOGY ON1Y UPON ENGINEER AND HEALTH DEPT. AUTHORIZATION SAS DESIGN PERCOLATION RATE - LESS THAN 5 MPI LONG TERM HYDRAULIC LOAD RATE - 0.74 GALIS.F. STDEWALL AREA: NOT APPLICABLE WITH BED -TYPE SAS BOTTOM AREA = 40'X 11.5'= 460.0 S.F. LOADING: (460 S.F.) 0.74 GALIS.FJDAY = 340.4 CPD TOTAL LEACHING CAPACITY -340.4 CPD PROVIDE BED - TtTE SAS, 40 FT. LONG X I15 FT. WIDE W/ 6 INCH EFFECTIVE DEPTH RESERVE AREA = 50'X 9'= 450 S.F. REQUIRES TANK AND P.C. RELOCATION *THE DESIGN IS NOT SUITABLE FOR USE WITH A GARBAGE DISPOSAL UNIT MR/IMIJM D -BOX q• UYER OF 1/4' 1O INSIDE DMENSCNS / VALVEpiuo 72•,12• 3/4' DIA. PEASTONE \PIPE SLOPE 0.5% VE BBOTTOM ELT O 1 RRES ,O u 70 S•A•S• H j COMPACTEDA AOF �-BOX W/ LAYER T1DIE. CRUSHED STONE UNE(S) EYJTNG D -BOX MUST REMAIN LEVEL FOR 2'-0' ING DOWN 70 PUMP CHAMBER LEACHING FAm A CprTRACTCR SHALL CONTACT SEE SPECIFICATIONS ENCKER FOR VW LAYOUT SEPTIC SYSTEM PROFILE NO SCALE 3/4• TO 1-1/2' DIA, DDIJBF-WASHED NAIIK STONE N BED MNYI-BACKED CONCRETE "-"�-""'- ^" Toa•at BARRIER WALL e/ STONE p¢ i --•-T -per FACEt3.`�R -.{I DIA PERF PVC PIPE 3s' I PERRY fl 3 t CIVIL S.A.S. CROSS SECTION 1ygPg NO SCALE SOUIRES.DWG RQ. AVE LOCUS KEY MAP NO SCALE FOLUNS I POND YARMOUTH, MA LEGEND ® PROPOSED CONTOUR EXISTING CONTOUR W WATER UNE OVERHEAD W.RES DRAIN UNE PROPOSED 15M GAL SEPTIC TANK o PROPOSED DISTRIBUTION BOX ® PROPOSED S.A.S. [-] PROPOSE➢ RESERVE AREA (p� PROPDSED PUMP CHAMBER EXISTING SPOT GRADE ® PROPOSED SPOT GRADE w TEST HOLE LOCATION R GROUNDWATER ELEVATION HAS BEEN DETERMINED BY FRIMPTER METHOD. APRIL 28 SOIL TESTS FOUND GROUNDWATER ELEV. - 0.75 RESTRICTED BY SUBSURFACE PEAT; FRMPTER ADJUSTMENT OF 0.3 FI. ADJ. HIGH GROUNDWATER ELEV. =1.1( USE ELEV. = 2.4 FOR DESIGN) TOPOGRAPHIC SITE PLAN SHOWING PROPOSED CONSTRUCTION OF A SINGLE FAMILY DWELLING AND SUBSURFACE SEWAGE DISPOSAL SYSTEM AT 79 MERCHANT AVENUE, YAEMOUTHPORT, MA ASSESSORS MAP 127, FARCEL 33 PREPARED FCR SUSANNE MCIN[RNEY NOVEMBER 30, 2010 ESCALE - AS NOTED PREPARED BY CAPE COD ENGINEEMG, INC. ROBERT M. PERRY, P.E. P.O. BOX 1517 EAST DENNIS, MA 02641 508-385-1445 TCP OF FCUNDAnON EL X100 FlN:SH GRADE EXISTING DWELLING i 1z' WATER 01 P ., GATE : fc r �YJ tom•,- , i II 9\V v rs' M< \ % tZ1 Fri/ O ` PROPOSED PERVIOUS \ I R I DRI CATCH BASIN TCH RIM=6.1 (BASIN TO B INV=4. A. (REPLACED w/ SOLID 6' s ,L 70' FROM TOP OF 8 DIA. x 3.5' H BASIN ■tIF J / CATCH BASIN R,A,=F 2 DECK /urrtLLlrvG i� � i OF7-90 - � 7r PLAN 20 1 inch = 20 & MANHOLE AND COVER-M!N 24• DIA. RAISE COVERS r0 WTHW 6• OF FINISH GRADE 5,0 T a 425 GJ 4.0 =S4 0 6. O 3/4- TO --- - - - 1-1/2' DA. STONE i BELOW TANK ULTRLIAOLE SEPTIC TANK DISINFECTION UNIT PRECAST REINFORCED CONCRETE NOTE" CAPACITY: 1500 GALLONS ALL PIPE TO BE 4" DIA. (H-20) PVC TIGHT JOINT WITH MINIMUM SLOPE OF 1/0' PER FT. OF 118" RAI r� i 1. THE WORK AREA SHALL BE DESIGNATED WITH A WORK LIMIT ViSTALLED AS SPECIFIED BY THE YARMOUTH CONSERVATION COMMISSION WHERE SHOWN. THE WORK LIMIT SHALL REMAIN IN PLACE UNTIL THE WORK IS COMPLETE AND THE AREA CLEARED OF MINOR DEBRIS WITH FULL GROUND COVER RESTORATION. 2. NO CONSTRUCTION WORK-RELATED ACTIVITY SHALL OCCUR BEYOND TTIE WORK LIMIT. 3. ACCESS TO THE WORK SITE SHALL BE VIA THE STREET AND PROPOSED DRIVEWAY AREA. 4. ALL PRUNED BRANCHES, VINES AND / OR ROOTS AND SLASH SHALL BE REMOVED FROM THE PROPERTY. 5. THE SITE SHALL BE RESTORED TO A THICKLY VEGETATED CONDITION WITHIN THE 50 FT. BUFFER BY THE PLANTING ABUNDANT NATIVE SHRUBS. A LANDSCAPE PLAN CAN BE MADE AVAILABLE TO DEMONSTRATE THE MITIGATION PORTION OF THE PROJECT. 6. ALL WORK SHALL BE IN ACCORDANCE WITH TITLE 5 AND TOWN OF YARMOUTH HEALTH CODE AND CONSERVATION COMMISSION REQUIREMENTS. 7. CONTRACTOR IS REMINDED TO REFER TO THE ORDER OF CONDITIONS ISSUED FOR THE WORK ACTIVITY BY THE YARMOUTH CONSERVATION COMMISSION. t Q GENERALNOTES 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE CATCH �, B f; / BASIN RIM WHERE SHOWN. CONTACT CAPE COD ENGINEERING, INC FOR q Vk ADDITIONAL ELEVATION USTFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY PREPARED BY SCHOFIELD r BROTHERS OF CAPE COD, INC; ROBERT FREEMAN, PLS; MARCH, 11, 2010 AND PUN BOOK 179, PAGE 49 LOT 11 Cr 8�K l' I - 3. All. SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO TAE STATE SANITARY CODE, TITLE 5 AND TOWN OF YARMOUTH ` / HEALTH BOARD APPROVAL FOR THE DESIGN. elevation Z 4. PERCOLATION TESTS SHALL BE PERFORMED TO VERIFY A 5 MPI OR FASTER texture color I BUILDING 7.0-6.7 0-9 POND PET"RVNDcovUR� RIAPPOAL AN�CTIONAPPROVAL FOR THE NEW YTEM. 10 YR 311 Q (TIDAL) 5. INSTALLATION CONTRACTOR SHALL VERIFY THE SEPTIC SOIL PIPE CONDITION 9-26 R L. Sand AT THE FOUND 4TION AS SET BY THE PLUMBER PRIOR TO MAKING �� �P • Q . ° ' : o I CONVECTION TO THE NEW SEPTIC TANK CN Sand. loam 10 YR 6/ 6. A 5 FT. PERIMETER EXCAVATION IS REQUIRED TO REMOVE THE SURFACE SONS INK,' o 55- 84 AND OTHER UNSUITABLE SOIL. SOIL TESTS INDICATE A DEPTH OF RE510VAL IS PEAT APPROXIMATELY 7 FT. BACK FILL WITH CLEAN SAND MEETUNG TITLE 5 0--i 184- 96 1 C3 SPECIFICATIONS FOR FILL. CONSTRUCT THE SAS IN THF. NEW MATERIAL. 7. INSTALLER SHALE. CONTACT ENGINEER AT TIME OF SYSTEM COMPLETION FOR I SYSTEM CERTIFICATION AS REQUIRED. 8. CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOU. CONDITIONS ENCOUNTERED DURING CONSTRUCTION. 9. NO KNOWN WELLS EXIST WITHIN 200 FT. OF TTIE PROPOSED SEPTIC SYSTEM OTHER TITAN TTIOSE SHOWN. _ C 10. DRIVEWAY SHALL. BE OF SEMI -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN FOR SITE RESTORATIPON IM ITICATION PLANS. PFS -G DATA HYDRAULIC LOADING - 3 BEDROOMS X 110GPDBR = 330.0 GPD SEPTIC TANK DESIGN 8" CORRUGATED PIPE INV=3.3 200% X 330 GAL. = 660 GAL. - PROVIDE 1500 GALLON TANK UNIT SIZED FOR f SINGULAIR BIO -KINETIC WASTEWATER TREATMENT SYSTEM. OBTAIN SYSTEM yr DEEP OBSERVATION HOLE #I SUPPLIER 0 & M CONTRACT PRIOR TO CONSTRUCTION APPLICATION. SUPPLY Tdt Date: April 23, 2010; EQUIV F,QUIVALENT TF.CFLN'OLOGY ONLY UPON ENGINEER AND HEALTH DEPT, I N ;tness: AMY VONIIONF., RS, YARM017R HEALT11 DEPT. AUTHORIZATION P RFORMED RY Robert M. Perry, P.E. elevation depth (in.) horizon texture color mottling other 7.0-6.7 0-9 A L. Sand 10 YR 311 PROPOSED 1500 GAL SEPTIC TANK Fill 6.7-4.8 9-26 R L. Sand 10\'R 516 Fill 4.8-2.4 26-55 CN Sand. loam 10 YR 6/ TEST HOLE LOCATION Fill 2.4- 0 55- 84 C2 PEAT 0--i 184- 96 1 C3 11led.sand PERCOLATION RATE - LESS THAN 5 MPI LONG TERM HYDRAULIC LOAD RATE = 0,74 GAIJS.F. SEDEWALL AREA: NOT APPLICABLE WITH BED -TYPE SAS BOTTOM AREA = 40'X 11.5'= 460.0 S.F. LOADING: (460 S.F.) 0.74 GAUSFJDAY - 340.4 GPD TOTAL LEACHING CAPACITY =340A CPD PROVIDE BED - TYPE SAS, 40 FT. LONG X 115 FT. WIDE 1V/ 6 INCH EFFECTIVE DEPTH RESERVE AREA = 50'X 9'= 450 S.F. REQUIRES TANK AND P.C. RELOCATION Parent material: Glacial Outwash (Fill to 55 inches) *TAE DESIGN IS NOT SUITABLE FOR USE WITH A GARBAGE DISPOSAL UNIT Depth to Groundwater. 69 inches ( ei.. l3) Not percolation tented due to groundwater; assumed less than 5MP1 in C3. Future testing shall be by de -watering or other location. R,F 2 MERCHANTS AVE LOCUS KEY MAP NO SCALE FOLONS POND YARMOUTH, MA LEGEND PROPOSED CONTOUR EXISTING CONTOUR W WATER LINE OVERHEAD WIRES DRAIN UNE i O 67 PROPOSED 1500 GAL SEPTIC TANK o PROPOSED DISTRIBUTION BOX PROPOSED SASS PROPOSED RESERVE AREA PROPOSED PUMP CHAMBER DOSTINO SPOT GRADE ® PROPOSED SPOT GRADE a TEST HOLE LOCATION ;flTi104� `i4y14 GROUNDWATER ELEVATION HAS BEEN DETERMLVED BY FRIMPTER METIIOD. APRIL 28 SOIL TESTS FOUND GROUNDWATER ELEV. - 0.75 RESTRICTED BY SUBSURFACE PEAT; FRI.MPTER ADJUSTMENT OF 03 FT. ADJ. HIGH GROUNDWATER ELEV. =1.1( USE ELEV. = 2.0 FOR DESIGN) __1- -- - - - -- - - -- -- - - - -- -- ---- -- FlNI� �R�E- - - --- - TOPOGRAPHIC SITE PLANT SHOWING PROPOSED CONSTRUCTION OF M'N.'M'JM D-BOs VALVE� � -,,,,,--INSIDE aMEN9ans 2• LAYER OF 1/4• TO A SINGLE FAMILY DWELLING 12'.12' 3/4 DIA. PEASTONE \ ANT SUBSURFACE SEWAGE DISPOSAL SYSTEM VE 1 i PIPE SLOPE osx - - - ---- -- - --- AT BO TOM n.=7D 79 MERCHANT AVENUE, YARMOUTHPORT, MA 7 a PIPES i0' ASSESSORS MAP 127, FARCEL 33 8.00 7.83 7 70 PREPARED FCR r 3;4 TO +-1/2- DIA. DouBLE-wn;NFo SUSANNE McINERNEY t:APK STONE N BED COMPACTED BASE D -130X _ _ _ _ i NNYL.-BACKED CONCRETE .iqr, OP CRUSHED STONE LIINNE(S) EXITING D -BOX MUST -T:F"'•--"' -� roa'8.2 BARRIER WALL ./ STONE q'� REMAIN LEVEL FOR 2'-0' 3 FALL EN VEMBER 30, 2010 SCALE - AS NOTED PUMP CHAMBER BEAa°aN"'rAau rDw r0 T --TA 4' oln. FF P c PIPE µ. PREPARED BY t CCN-R.ACTOR SHALL CONTACT_ 6' \ ERRV a' SEE SPECIFICATIONS ENGINEER FOR VENT LAYOUT =55- - _ \ NIL CAPE COD ENGINEERING, INC. 4_ --ns' tN1a. 5880 ser ROBERT M. PERRY, P.E. SEPTIC SYSTEM PROFILE S.A.S. CROSS SECTIONS P.O. BOX 1517 NO SCALE NO SCALE EAST DENNIS, MA 02641 SOU i RES. D WG 508-385-1445 CATCH ' J BASIN TO Bq REPLACED •/ SCIUD 6' DIA. x 3.5 H BASIN I 0 1< EXISTING DWELLING tz of I r__ I ,,WATER GATE CJ 7S n � �e rs" 0 `• PROPOSED r° IPERVIOUS R � DRIVEWA TCH I , SIN 4 rI j� A R 10 35 y1 I a \STEPS ,.. S (i 3„ 0 F / iYrj-,i a�_�• CATCH BASIN 1 1 - - R:M=E 2 RI � DECK PLAN Of) V 77' OF 1I8f R 1-0 I inch - 20 M DcN MANHOLE AND COVER-M!N 24' DIA. RAISE COVERS TO Vfl Y'N 6' OF FINISH GRADE SH GRADE 114 4.0 INTRA=MOLE SEPTIC TANK nICINEECTION UNIT PRECAST REINFORCED CONCRETE CAPACITY: 1500 GALlOt1S (H-20) 4" DIA, PATH DF 1/B' I' FOLLINS POND r (TIDAL) i� . v II `� ; r I i r' m OJT Qhs U DEEP ORSERV:ATION FI01-F Y i 1'1PL /%1ty Test Date: April 2A. 2010; e d ` AYitnne: A')SY VOr110`rF., RS, YARNICILT I I1EALTII DEPT. PERFORNIED RY Robert St. Perry. Ps - elevation depth (in.) herizon texture Arolor mottling other L. Sard 10 YR 311 Fill 7.0-6.7 0-9 A D 1- sans 10 VTR 516 Fill 6.7-4.8 9-26 4.A-2.4 26-55 C1 Sand. ham 10YR 61 (Fill 2A. 0 55- 84 C2 PEAT Parent material: Glacial Outwash ( Fill to 55 inches) CONSERVATION NOTES 1, THE WORK AREA SHALL BE DESIGNATED WITH A WORK LIMIT INSTALLED AS SPECIFIED BY THE YARMOUTH CONSERVATION COMMISSION WHERE SHOWN. THE WORK LIMIT SHALL REMAIN IN PLACE UNTIL THE WORK IS COMPLETES AND THE AREA CLEARED OF MINOR DEBRIS WITH FULL GROUND COVER RESTORATION. 2. NO CONSTRUCTION WORK.RELATED ACTIVITY SHALL OCCUR BEYOND THE WORK LIME. 3. ACCESS TO THE WORK SITE SHALL BE VIA THE STREET AND PROPOSED DRIVEWAY AREA. 4. ALL PRUNED BRANCHES, VINES AND I OR ROOTS AND SLASH SHALL BE REMOVED FROM THE PROPERTY. 5. SHALLTHE IT AEEPTHE SO FT. SITE Y THE PLANTING ABUNDANTIVE SHRUBS. LANDSCAPE CAN BE MADE AVAILABLE TO DEMONSTRATE THE MITIGATION PORTION OF THE PROJECT. 6. ALL WORK SHALL BE IN ACCORDANCE WITH TITLE 5 A- TOWN OF YARMOUTH HEALTH CODE AND CONSERVATION COMMISSION REQUIREMENTS. 7. CONTRACTOR YBTYREFER TO THE CONSERVATIONORDER CS SLED FOR ORCTIVITTHE YARMOUTH COMMIION. ("F\'FR 1A :lOT'ES 1. ELEVATIONS REFER TO NGVD 1929. ELEVATION BENCHMARK IS THE CATCH BASIN RLI WHERE SHOWN, CONTACT CAPE COD ENGINEERING, INC. FOR ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY PREPARED BY SCHOFIELD BROTHERS OF CAPE COD, INC.; ROBERT FREEMAN, PLS; MARCH. It, 2010 AND PLAN BOOK 179, PAGE 49 LOT 11 1. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO THE STATE SANITARY CODE, TITLE 5 ANT) TOWN OF YARMOUTH HEALTH BOARD APPROVAL FOR THE DESIGN. 4. PERCOLATION TESTS SHALL BE PERFORMED TO VERIFY A 5 MPI OR FASTER PERCOLATION RATE USING A DEWATERING PROCESS PRIOR TO BUILDING PERMIT APPROVAL AND CONSTRUCTION APPROVAL FOR THE NEW SYSTEM. 5. I\STALLATION CONTRACTOR SHALL VERIFY THE SEPTIC SOIL PIPE CONDITION AT THE FOUND `,TIO` AS SET BY THE PLUMBER PRIOR TO MAKING CONNECTION TO THE NEW SEPTIC TANK 6. A 5 FT. PERIMETER EXCAVATION' IS REQUIRED TO REMOVE THE SURFACE SOILS AND OTHER UNSUITABLE SOLI. SOIL TESTS INDICATE A DEPTH OF REMOVAL IS APPROXIMATELY 7 FT, BACK FILL WITH CLEAN SAND MEETING TITLE 5 SPECIFICATIONS FOR FILL. CONSTRUCT THE SAS IN THE NEW MATERIAL. 7. INSTALLER SHALL. CONTACT ENGINEER AT TIME OF SYSTEM COMPLETIONFOR SYSTEM CERTIFICATION AS REQUIRED. & CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOIL CONDITIONS ENCOUNTERED DURING CONSTRUCTION. 9. NO KNOWN WELLS EXIST WITHIN 200 FT. OF THE PROPOSED SEPTIC SYSTEM OTHER THAN THOSE SHOWN. IO.DRIVEWAY SHALL BE OF SEMI -PERVIOUS MATERIALS. SEE LANDSCAPE PLAN FOR SITE RESTORATIPON I MITIGATION PLANS. DESIG"ATA HYDRAULIC LOADING - 3 BEDROOMS X 110GPDIBR= 330.0 GPD SEPTIC TANK DESIGN 200% X 330 GAL = 660 GAL. - PROVIDE 1500 GALLON TANK UNIT SIZED FOR SINCUL.AIR BIO -KINETIC WASTEWATER TREATMENT SYSTEM. OBTAIN SYSTEM SUPPLIER EQUIVALENTECHNOLOGYO LYYUPO M CONTRACT PRIOR TO CONSTRUCTION OSUPPLY E.'GM RANDHEALTHDEPT. AUTHORIZATION S&DESIG>v PERCOLATION RATE - LESS THAN 5 MPl LONG TERM HYDRAULIC LOAD RATE - 0.74 GALIS.F. SIDEWALL AREA: NOT APPLICABLE WITH BED -TYPE SAS BOTTOM AREA = 40'X 11.5'= 460.0 S.F. LOADING: (460 S.F.) 0.74 GAIIS.FJDAY = 340.4 GPD TOTAL LEACHING CAPACITY - 340A CPD PROVIDE BED -TYPE SAS, 40 FT. LONG X 11.5 IT. WIDE W/ 61NCH EFFECTIVE DEPTH RESERVE AREA = 50'X 9'= 450 S.F. REQUIRES TANK AND P.C. RELOCATION Wrnc -10-0IS NOT SUITAR1 F t•'nR 115E i 11 n AC RARA QACE DISPOSA>UNIT Depth to Groundwatel69 inches ( e . Not percolation toted due to groundwater; assumed iess than 5?SP1 in 0. Future luting shall be by de -watering or other location. CWPACTED BASE - L)-bVA Rau - *1 6- LAYER OF LINES) E%11NG D -BOX MUST CRUSHED STONE REMAIN LEVEL FOR 2'-0' BEFORE PITCHING DOWN IO pump CHAMBERLEACHING FA( . c TRAcroR SHALL CONTACT SEE SPECIFICATIONS ENGINEER FDR VB47 LAYOUT SEPTIC SYSTEM PROFILE NO SCALE 2' LAYER OF 1/4' TO 3/4' DIA. PEASTONE \ l` PIPE SLOPE 0 sx 40 TD �, 3/4' TO 1-1/2' DIA. COUBLE-WASHED 1,ADVE STONE N BED ,+AMYL -BACKED CONCRETE TpN-62 BARRICR WALL a/ STONE FACE --TT-4 M4 PE SFS CROSS SECTION NO SCALE SOUIP.ES.DWG MERCHANTS AVE LOCUS KEY MAP NO SCALE FOLLINS I POND YARMOUTH, MA LEGEND -tom PROPOSED CONTOUR E)JSTING CONTOUR W WATER LINE - OVERHEAD WIRES cj [1 DRAIN LINE PROPOSED 1500 GAL SEPTIC TANK o PROPOSED DISTRIBUTION BOX ® PROPOSED SAS PROPOSED RESERVE AREA PROPOSED PUMP CHAMBER EXISTING SPOT GRADE 1 ® PROPOSED SPOT GRADE TEST HOLE LOCATION GROUNDWATER ELEVATION HAS BEEN DETERMIYED BY FR MI TER METHOD. APRIL 23 SOIL TEST'S FOU'N'D GROUNDWATER ELEV. = 0.75 RESTRICTED BY SUBSLRFACE PEAT; FRIM MI ADJUSTMENT OF 03 FT. ADJ. HIGH GROUNDWATER ELEV. -1.1 ! USE ELEV. = 2.1 FOR DESIGN) TOPOGRAPHIC SITE PLAN SHOWING PROPOSED CONSTRUCTION OF A SINGLE FAMILY DWELLING AND SUBSURFACE SEWAGE DISPOSAL SYSTEM AT 79 MERCHANT AVENUE, YAEMOUTHPORT, MA ASSESSORS MAP 127, FARCEL 33 PREPARED FCR SUSANNE McTi�ERNEY OVEMBER 30, 2010 SCALE - AS NOTED PREPARED BY ET`s a1. CAPE COD ENGINEERING, INC. PERRY ROBERT M. PERRY, P.E. °31 80 a P.O. BOX 1511 F . B a` EAST DEWS, MA 02641 0 508-385-1445