HomeMy WebLinkAbout83-1888 - Site Plan002ACCESS COVERS MUST BE WITHIN - 6' OF FINISH GRADE 28.8 FIRST 2' TO I I BE LEVEL? / 9' MINIMUM, 3' MAXIMIJAI COVER MIN 2' OF PEASTONE OR FILTER FABRIC 3/4' - 1 1/2' DIA. \25.0 _ UJ t `-LI / 24.0 LJ 9; 23.7 2' H-20 DOUBLE WASHED STONE 24.25 &AFFLF- 23.87 � 23.5 -� � 21. 5_ 3 OUTLET 3-500 GAL LEACHING CHAMBERS D -BOX W/4' STONE AROUND. 33'. x 15'1 x 2'd 1500 GAL H-20 SEPTIC TANK 6' CRUSHED STONE OR {� H-20 COMPACTED BASE 0� PROFILE : NOT TO SCALE BVI) I _ N (� �e. a U ooc _ dVW 2 ' L l TOP WATER 7.0 (012J/20/0) PER YARMLJTH OUAD SHEET brz SHED TO BE +IF'tY REMOVED 44,0 �,• 0 40BVW 3 B.6 /, C' � y 4 C57/ SHED 7-0 HE RELOCATED RVW , L 0 T' 6 3 r c � FENCE POST 9.5 - 13;471" SF UPLAND r = � z A J. /' PD 60b i INVERT ELEVATIONS: INVERT AT BUILDING: 25.0 INVERT /N SEPTIC TANK: 24.25 INVERT OUT SEPTIC TANK: 24.0 INVERTIN DIST. BOX: 23.87 INVERT OUT DIST. BOX: 23.7 INVERT IN LEACH CHAMBER:' 23.5 BOTTOM OF LEACH CHAMBER: 21.5 ADJUSTED GROUND WATER. N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE ♦1: 16.5 CONSERVATION NOTES: I . THE WORK LIMIT SHOWN SHALL BE FITTED WITH ASILT. FENCE AS REOUIREft BY THE CONSERVATION COMMISSION. THE FENCED WORK LIMIT SHALL CONSIST OF A CONTINUOUS. STAKED. DUG -IN FABRIC SILT FENCE. THE FENCE SHALL REMAIN IN PLACE UNTIL THE DISTURBED GROUND IS STABILIZED COMPLETELY. PROVIDE ALTERNATE SILT FENCE SUCH AS STAKED HAYBALES IF NEEDED AS DIRECTED BY THE CONSERVATION COMMISSION. 2.' NO CONSTRUCTION RELATED ACTIVITY SHALL OCCUR ON. THE WETLAND SIDE OF THE WORK LIMIT. 3. ROOF DRAINS SHALL BE DIRECTED TO SUITABLY SIZED DRYWELLS FOR STORMWATER RUNOFF CONTROL. 4. INITIAL. SOIL STABILIZATION WITHIN THE WORK LIMIT SHALL BE ACCCMPLISHED BY APPLICATION OF MULCH AND/OR LOAM -AND -SEED WEATHER PERMITTING. 5. ACCESS FOR DEMOLITION AND CONSTRUCTION SHALL BE VIA THE STREET SIDE OF THE PROPERTY WITH LIMITED ACCESS AS SHOWN AROUND THE PROPOSED DWELLING SITE. 6. ALL. DEBRIS SHALL BE LADED FROM THE SITE AS IT IS PRODUCED AND TRANSPORTED TO A SUITABLE SOLID WASTE HANDLING FAC I L / TY. 7. REFER. TO ANY ORDER OF CONDITIONS ISSUED FOR THE PERFORMED WORK ACTIVITY BY THE YARMOUTH CONSERVATION COMMISSION. +j ' 05 s _tz3�' �' PPZg6 S. b/ i `SOE - - 3-500 CALLON EACHING CHAMBERS UPO- .c W/4' STONE AROUND _ n q0 / P05E9 'o � N\ C (jy 3 1500 GALLON \L7 SEPTIC TANK $T ' ➢ f m! 0 6 \ . V BAI. CATCH BASIN ^ 1 RIM -26.14 1 �rT 0 10 20 40 DESIGN CRI TER IA: DESIGN FLOW. 4 BEDROOMS AT /10 G.P.D. PER BEDROOM EQUALS 440 G.P.D. NO GARBAGE GRINDER . SEPTIC TANK REQUIRED: 440 G.P:D. X 200x - 880 GAL. SEPTIC TANK PROVIDED., 1500 GAL. MIN. -SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 440 GPD / 6.74 GPD/SF - 595 S.F. REQUIRE PROVIDED: 3-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-606 S.F. 606 S.F. x 0.74 - 448 G.P.D. SOIL TEST PIT DATA q INDICATES _L7 INDICATES PERCOLATION OBSERVED TEST - GROUNDWATER TP W1 0. NORIZON TEXTURE COLOR 265 FILL - 12' _ - 25.5 LOAMY IOYR SAND 3/3 l6' _ _ 25.2 n LOAMY IOYP. SAND 5/8 24' C _......... ..... ........ 24.5 I 'MEDIUM l0YP SAND 5/8 42' 120- NO WATER 16.5 DATE: OCTOBER 7. 2010 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: l 2 MIN/INCH _ LEGEND @'CB CONCRETE BOUND -W-- WATER L I NE O HYDRANT -G- GAS LINE - OHW- OVER HEAD WIRES # LIGHT POST -E- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE - CTV_ UNDERGROUND CABLEVISION LINE -40.4 SPOT ELEVATION ,-40-- EXISTING CONTOUR 40 PROPOSED CONTOUR ' 77 i5'1zo7o, 4 GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THF. SEWAGE DISPOSAL SYSTEM AND PERMITTING PURPOSES ONLY. 2. VERTICAL DATUM IS APPROXIMATE NGVD, FOR BENCH MARKS SET, SEE SITE PLAN. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4, ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER REQUIRED AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE.. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL -DIG -SAFE.. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. 9. ALL UNSUITABLE MATERIAL (A A B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED. WITH SAND. IN ACCORDANCE WITH TITLE 5. 10. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS, SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. /I. l7 SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING.' S / TE PL A O� L 14 /V0 77 / IVO / AIV MEMOR / AL DR / VE. ii/IAP 69 . PARCEL / O S 0 U T1--1YA R Ii/'Q (1 if --1 . Mf A PREPARED 1=0R: E-10 W14 R D P KA VA /V,4 G H ,35SOUTHBUR Y ROAD . CUMBERLAND . RI 02864 SCAL E : / - 20 SEP TEMBER 2-1p. 20 / O EAGLE SURVEYING, INC 923 Route 6A Yarmouti-hpart, MA. 02675. ( 508 362-8132 ( 508) 432-5333 REVISED: OCTOBER 8. 2010 NOVEMBER 4, 2010