Loading...
HomeMy WebLinkAboutReview Checklist �=�� .-.� � ����� � TOWN OF YARMOUTH �" " ` � y � SEWAGE PLAN REVIEW CHECKLIST /'�f r - ��''��� �i ` '� � o �� ���>` " C%L. (_��.< � , Location: A.M.__�C� Lot Zone of Contribution: In,��-Out_ Acreage `` � .�'�Z%� /� Commercial: Residential:�-------' Street: � C_..C� � � � Village: � Floor Plan: ` ��. #Bedrooms: �--� Owner: (���%Z�!� Insta ller: �dZ'I Address: Phone: - 77 -^�'r p''-7 Phone: Builder: Engineer: ���' Address: Phone: � ���.�' --�.- Phone: - v��.I . �� %,`.L�/ ,��'�_ , �� N/A YES NO l.Re uired#of co ies received 2. Date of soils exam and percolation test not older than 2 years �`_-� 3.4-5 ft of naturall occurrin ervious material, above water table `---- 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: �.__--- 6.Benchmark indicated and shown-NGVD if near wetlands �._.--�'` 7. S tic tank minimum 10 ft from foundation, deck Var.: �t.�-' 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: <._._--+ 9.Leaching minimum 100 ft from wetlands Var.: 10.Leachin minimum 150 ft from drinking welU25 ft irrigation well Var.: �----- 1 l. Tank/leaching minimum 10 ft from roperty line Var.: ,�-�-�'" 12. S stem meets all other setback r uirements Var.: _.�-'" 13.Uses adjustment for maximum high oundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: �,,/ 15. System not in to or subsoil(A,B horizons)or 5'removal :�- 16.Pro osed contours are suitable �.--- 17. S stem meets slo e re uirements-min. 1/8", '/4" referred � 18. System meets breakout requirements PVC liner: Wall: `�, 19. S ecified tee sizes are ro er, gas baffle on outlet tee � 20. Sewa e is under 10,000 d for parcel 21.No garba e dis osal •�___...,. 22.S stem ade uatel sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox �.____ • 24.Manhole covers within 6"of ade, um chamber cover to ade 25.Ins ection port on lastic chambers/leach field 26. Electrical ermit for um chamber/Se arate meter for du lexes 27.Pum system-2"line,wee hole,check valve,tee in dbox,pump size 28. S tic tank/pump chamber to be factory wat roofed 29. Vent rovided if leachin below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/ um chamber - 31. En " eer to ins ect and cert' soils: wall: commercial: - 32.Engineer/Registered Sanitarian and Land Surveyor stam s/si ture 33. H-201oadin is subject to vehiculax traf�c, groundwater 34. Title V A lication and ermit fee, installer signature 3 5.Foundation footing min. 2 feet above ad'usted ound water for new house �- 36.Deed Restriction r uired max. #bedrooms: ma�c. flow: d •�''- 37. Check area.lots for groundwater/Label groundwater in Assessor's , Plan reviewed by: ��'`-� 6/03/03