Loading...
HomeMy WebLinkAboutReview Checklist �'- / 3 -1� TOWN OF YARMOUTH a SEWAGE PLAN REVIEW CHECKLIST Location: A.M.� Lot ( Q Zone of Contribution: In Out�Acreage� • Commercial: Residential: S�eet: ` �- � ; ;2� / Village: . �/� Floor Plan: ✓ #Bedrooms: � Owner: d2� ' Installer: , /� G� Address: Phone: Z � D Phone: Builder: '� Engineer: l.�S5 G�.�l� Address: Phone: � Phone: �`G`,�,,. `_ � ;'Y-, �4 , _-� N/A ' YES NO 1.R uired#of copies received 2.Date of soils exa.m and ercolation test not older than 2 years (�� 3.4-5 ft of naturall occurrin ervious material, above water table ��-� 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation,deck Var.: 8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leachin minimum 100 ft from wetlands Var.: 10.Lea.chin minimum 150 ft from drinkin we1U25 ft irrigation well Var.: 11.Tank/leachin minimum 10 ft from rop line Var.: � 12.S stem meets all other setback r uirements Var.: c�- 13.Uses ad'ustment for maximum high oundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: �.-- 15.S stem not in to or subsoil(A,B horizons)or 5'removal 16.Pro osed contours are suitable �' 17. S stem meets slo e r uirements-min. 1/8", '/4" referred �--� 18. System meets breakout re uirements PVC liner: Wall: 19. Specified tee sizes are pro er, as baffle on outlet tee `--�' 20. Sewa e is under 10,000 d for arcel , 21.No ba e dis osal �� 22.S stem ade uatel sized for its intended use �.1 23.Minimum 6"stone or compacted below tank and dbox - 24.Manhole covers within 6"of ade, um cha.mber cover to ade 25.Ins ection ort on lastic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pum system-2" line,weep hole,check valve,tee in dbox, um size --� 28. Septic tank/pum chamber to be factory wat roofed 29.Vent rovided if leaching below 3 feet,under driveway/ arkin 30.Buoyancy calculations for tank/ ump chamber 3 l.En ' eer to ins ect and cert' soils: wall: commercial: � 32.Engineer/Re ' ered Sanitarian and Land Surveyor stam s/si ture � 33.H-201oadin is sub'ect to vehicular tr�c, groundwater 34.Title V A lication and ermit fee, installer si ture 35.Foundation footin min.2 feet above adjusted ound water for new house 36.Deed Restriction r uired max. #bedrooms: max. flow: d - 37.Check area lots for oundwater/Label oundwater in Assessor's Ma Plan reviewed by: ' `'1 �o�io3