Loading...
HomeMy WebLinkAboutEngineered Plan - 2016SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE 43.7' FILTER FABRIC OVER STONE 4� 3.0'1 ►IMI►1I I►/ 7C• AC t' WED nvrD MMrnAc• ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 142.5 NOTE: 2" MIN. WALL PRECAST H-10 THICKNESS REQUIRED BLOCKS OR RISERS (TYP.) PRECAST RISERS 2'0 4"OSCH40 PVC MORTAR ALL H-10 10'�1� PIPES LEVEL 1ST 2' 4' COMPONENTS 4' L�YE(JJE FENDS (NP') SIDES EL. 3 -. . ; -1014" *41.6 10" 1500 GAL H . 0 0 O°o.°°.°.°°.°o.°° o39.24 TEE SEPTIC TANK TEE ®O® o ®I��-C®00 O1 E21 6 0 .1\,38.99 >oo00°.' 00 °°°�0°0°°°°0o°o°°0°°o°o0° o o o°o°o°o00°°0°0°°GAS BAFFLE.., 1 N 0°0000o° 0-0. >°00000®°°D0°°O°0°O°0°oO 738®S� 89 000 0000 °°°°4' LIQ. LEVEL (ACME OR EQUAL) 3. . , a :::.. 't, ...-.,..:••:.:.:• ,, .. , ..:. • ......,..... EL. 36.7 coo°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o°o ^°°°°°"°"°^°'°'°"°°°°°°°°°°�"�"0"`"000000°' 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H1 L -10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) c (_8.7% SLOPE) (-1-7. SLOPE) (-L-% SLOPE) 27' SEPTIC TANK 2' D' BOX 12' FOUNDATION- LEACHINGFACILITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE, FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10 CONTRACTOR SHALL BE RESPONSIBLE FOR Knob Nill 0o d OIL) pl ° �P ,-2 "/77 PaA NEriok5s Pain Locus 00rin9 in z Qti Ban Hi 0h rands .c o` c 0 Z CALLING DIGSAFE (1-888-344-7233) AND 31.5' BOTTOM TH-1 VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP NO GROUNDWATER FOUND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF. WORK. NOT TO SCALE 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE ASSESSORS MAP 91 PARCEL 28 PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. SUN ROOM 99 PROPOSED CONTOUR FAMILY ROOM (98.4) PROPOSED SPOT EL. TH 1BEDROOM R? 84TH KITCHEN DINING ROOM TEST HOLE YY GARAGE 2� SLOPE OF GROUND LMNG ROOM coul UTILITY POLE BEDROOM BEDROOM FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING / O FLOOR PLANS NOT TO SCALE' 12� . -79 TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS (YARMOUTH) DATE: 3/24/16 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. 1 0°f 42.5' A /LS 0, 10YR 3/2 14" ///// 1OYR 5/6 40.5' 24" i i i i i ® UNSUITABLE SOIL 2.5Y 6/4 / , 54" i/ z z z 38 PERC I Y I C2 MS 2.5Y 7/6 132" 31.5' NO GROUNDWATER ENCOUNTERED LICE #16-078 \1 5' REMOVAL OF UNSUITABLE SOIL REQUIRE AROUND PERIMETER OF LEACHING FACILITY DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) PAVED DRI \ , GARAGE W/ o SHED ,/� O ID EXISTING w ` DWELLINt; .+ TOP OF FNDN EL 43.7 • s 'ti �tit�' "lift' •tom � - � •�+�,it•tsp+t1� tt �it���• • �`tfa/Mrl'rlr �1 • I BENCHMARK: BULKHEAD COR. =43.1 NAVD88 Scale:1 "= 20' 0 10 20 30 40 50 FEET f �X X SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD - ---- =-- kiSt- -330- -GPD- DESIGN-FLOW _'- SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND e13Y� APPROVED MA DATE BOARD OF HEALTH G / TITLE 5 SITE PLAN G OF #61 OUT OF BOUNDS DRIVE YARMOUTH, MA MAY ��'� PREPARED FOR HEALTH DEPT. PATRICIA CAFFREY Ynrm, or th MenIt"a Depne a emt ,i1. VED Name Date DATE DANIEL A. OJALA, P.E., P.L.S. DATE: MARCH 24, 2016 off 508-362-4541 I fax 508-362-9880 downccpe.com 00WO cfpe engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-078