HomeMy WebLinkAboutEngineered Plans - 201694.0 s '-
>\Olp-�cl
Ott
95.3\ SPO ,-C 00 0
2 �� .0
T
\ EXIST. 1,000G
/-- \ SEPTIC TANK 92
1 I \
i \ 1 90.5 \
I 1 i 92
� 91
1 -J2 91
93
I
93
Permit valid for REPAIR OF SEP'TIC SYSTEM
ONLY, due to State and Local septic variances.
Board of health review and approval is required for
any future additions/renovations/alterations to
sewage facilities,and/or str-uctures/dsvelling.
Yarmouth Mealt4 0cpartntent
APMOV.ED/4)t
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
— 310 CMR 15.405 (1) (8):
1) A 1.86 Fr. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING
To BE 4.86 Fr (MAX) BELOW GRADE VS REWD 3 Fr. (H20/VENT PROVIDED)
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. DWELLING IS SERVICED BY TOWN WATER.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK.
10. EXISTING LEACH PITS TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY
13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING
14. ALL PIPING TO BE 4' SCH 40 0 1/8`/Fr (UNLESS SPEC.
15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW
FOR THE USE OF A GARBAGE GRINDER.
16. N WETLANDS WITHIN 100 Fr. OF PROPOSED LEACHING
TITLE REF: 28940/071
PARCEL ID: MAP 125 PAR. 090
LOT SIZE: 0.29 ACRES
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
7 OUTWARD REACH ROAD
YARMOUTH, MA
PREPARED FOR
PINTO/
RODNEY FISHER EXC.
AUGUST 12, 2016
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle5@gmail.com
SHEET 1 OF 2
853
LEGEND
YARMOUTH
PROPOSED CONTOUR
® PROPOSED SPOT GRADE
a
EXISTING CONTOUR
+ 96.52 EXISTING SPOT GRADE
0
Y
6P No RO•
N
W— EXISTING WATER SERVICE
i
RAJ Q1 `,QP
F RO
TEST PIT
NPG�
LOCUS,BpR
S�
0)
SCALE: 1"=20'
7 OUTWARD REACH
EIVEDV w
AU "i 5 2616
LOCUS A(WEALTH DEPT
LOCUS
INFORMATION
Permit valid for REPAIR OF SEP'TIC SYSTEM
ONLY, due to State and Local septic variances.
Board of health review and approval is required for
any future additions/renovations/alterations to
sewage facilities,and/or str-uctures/dsvelling.
Yarmouth Mealt4 0cpartntent
APMOV.ED/4)t
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
— 310 CMR 15.405 (1) (8):
1) A 1.86 Fr. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING
To BE 4.86 Fr (MAX) BELOW GRADE VS REWD 3 Fr. (H20/VENT PROVIDED)
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. DWELLING IS SERVICED BY TOWN WATER.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK.
10. EXISTING LEACH PITS TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY
13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING
14. ALL PIPING TO BE 4' SCH 40 0 1/8`/Fr (UNLESS SPEC.
15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW
FOR THE USE OF A GARBAGE GRINDER.
16. N WETLANDS WITHIN 100 Fr. OF PROPOSED LEACHING
TITLE REF: 28940/071
PARCEL ID: MAP 125 PAR. 090
LOT SIZE: 0.29 ACRES
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
7 OUTWARD REACH ROAD
YARMOUTH, MA
PREPARED FOR
PINTO/
RODNEY FISHER EXC.
AUGUST 12, 2016
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle5@gmail.com
SHEET 1 OF 2
853
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS
FINISH GRADE SHALL NOT BE < EL:87.64
FOR A DISTANCE OF 15' AROUND THE
PERIMETER OF THE S.A.S.
OF
9ssq�,
T.O.F. EL.=96.0 SEPTIC TANK
PROPOSED D -BOX PROPOSED
S.A.S.
�����
(BACKWALL) INSTALL RISERS & COVERS OVER INLET &
INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER VENT
D EN M. y
OUTLET AND SET TO 6" OF FINISH GRADE
SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G.
F.G. EL.=93.0± F.G. EL.=92.50±
F.G. EL: 92.0±
F.G. EL: 92.50(MAX.)
` N 1 4
9" MIN COVER/
36" MAX COVER L - 30'
0 S=1% (MIN.) EL 89.50 O S=1% (MIN.)
L = 10'(MAX)
0 S=1% (MIN.)
INSTALL TWO INSPECTION PORTS (MIN.)
SANITARY
4"SCH40 PVC .4"SCH40 PVC
4"SCH40 PVC
10�
6 11.3" TO
INV.= 88.45 as' ufwi0 INV.=88.20
INVERT
INV.= 87.25
BAF1a
GAS FLE
ROS>8%
PROPOSED
BOX INV.=87.7 4 ROWS OF 5 UNITS AT 6.25'/UNIT + 0.75' WEDGE = 32.0'/ROW
INv.=87.9
DB -5
SOIL ABSORPTION SYSTEM (PROFILE)
EXISTING 1.000 GALLON SEPTIC TANK
.(H-20)
RESTORE VEGETATIVE COVER
EXISTING SEWER OUTLET
BACKFILL WITH CLEAN PERC SAND
TO TOP OF CHAMBERS
75"
NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING
PLACE FILTER FABRIC
OVER CHAMBERS.
PIPE INVERTS PRIOR TO CONSTRUCTION
BREAKOUT=TOP ELEV.=87.64
2) D -BOX SHALL BE SET LEVEL AND TRUE TO
INV. ELEV.= 87.25
GRADE ON A MECHANICALLY COMPACTED SIX
BOTTOM ELEV.= 86.31
EXISTING SUITABLE
INCH CRUSHED STONE BASE, AS SPECIFIED IN
MATERIAL
310 CMR 15.221(2)
5' MIN. ABOVE BOTTOM OF
( 76" _
3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK
T.P. EXCAVATION OR G.W.
EFFECTIVE WIDTH = 4 x 2.83' = 11.32
WITH 1500 GALLON SEPTIC TANK IF FAILED,
(5.31' PROVIDED)
USE 4 ROWS OF 5 -HIGH CAPACITY
PROFILE
DAMAGED, NOT H2O LOADING, OR UNDERSIZED.
BOTTOM OF TESTHOLE EL.=81.30 __
ADS 1620BD BIODIFFUSER (H20) UNITS -NO STONE
4) INSTALL INLET & OUTLET TEES W/
GAS BAFFLE AS REQUIRED
W/ CONTOURED WEDGE
5) PLACE SANITARY TEE IN D -BOX. SEPTIC
SYSTEM PROFILE
TYPICAL SECTION
�
16„
N.T.S.
N.rs
11
SOIL LOG
**NO PROPOSED INCREASE IN FLOW**
�34"--�
DESIGN CRITERIA
DATE: JULY 13, 2016
SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE #1614
SECTION END CAP
NUMBER OF BEDROOMS: 4 BEDROOM DESIGN
WITNESS: AMY VONHONE, YARMOUTH HEALTH
SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE:
<2 MIN/IN
16" HIGH CAPACITY 1620BD (H-20) BIODIFFUSER UNIT
DAILY FLOW: 110 G.P.D/BR. DESIGN FLOW: 440 G.P.D.
Elev. TP -1 Depth
92.80 0"
GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER)
MODEL 16" HICAP
SEPTIC TANK: 440 gpd x 200% = 880 gpd USE EXISTING 1,000 GALLON
SEPTIC TANK
FILL
LENGTH 76" NOTE: UNIT CONFIGURATION AND AVAILABILITY SUB,IECT
LEACHING AREA REQUIRED: (440)/0.74 = 594.59 S.F.
90.30.' 30"
EFFECTIVE LENGTH 75" TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY
SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE.
DISTRIBUTION BOX: 4 OUTLETS (MINIMUM)(H-20 LOADIING)
LOAMY SANDDIFFER
10YR 3/2
SIDE WALL HEIGHT 11.3"
89.88 35"
B
OVERALL HEIGHT 16"
PRIMARY S.A.S.
LOAMY SANDOVERALL
10YR 6/6
WIDTH 34" 4640 7RUEMAN BLVD
HILLIARD, OHIO 43026
USE 4 ROWS OF 5 - 16" ADS 1620BD BIODIFFUSER H-20 UNITS
-NO STONE
87.30 C 66"
MEDIUM
CAPACITY 13.6 CF s
(101.7 GAL) ADVANCED DRAINAGE SYSTEMS, INC.
AND EXTENDED 0.75' W/ CONTOURED WEDGES
PROPOSED SEPTIC SYSTEM/SITE PLAN
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF BIODIFFUSER)
2.5"7/4
(BIODIFFUSERS) 20 UNITS x 6.25 LF x 4.73 SF/LF = 591.25 SF
(CONTOURED WEDGE) 4 ROWS x 0.75' x 4.73 SF/LF = 14.19 SF
81.30 138"
7 OUTWARD R EACH ROAD, YARMOUTH, MA
TOTAL AREA = 605-44 SF
DESIGN FLOW PROVIDED: 0.74GPD/SF(605.44SF) = 448.02 GPD
> 440 GPD req'd
PERC. RATE <2 MIN/IN. SOI�S IN ("C' HORIZON) PER SIEVE SAMPLE
Prepared for: Pinto/Rodney Fisher Exc.
Engineering and Surveying by:
Meyer&Sons, Inc.
SCALE
NTS
DRAWN
D.M.M.
PATE:
08/12/16
NO GROUNDWATER OBSERVED
1, Darren M. Meyer, R.S., CSE, hereby
certify that I am currently approved by MADEP pursuant to 310 CMR 15.017
PO BOX 981
REV. DATE:
CHECKED
SHEET NO.
:I
to conduct soil evaluations and that the above analysis has been performed by me consistent with the
EASTSANDW/CH, MA 02537
requirements of 310 CMR 15.017.
1 further certify that 1 have passed the Soil Eval. Exam in October, 1999.
50e-Wz922
D.M.M.
2 2
of