HomeMy WebLinkAbout83-1907 - Old Plans - Septic Design007SOIL TEST
TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE
DATE OF SOIL TEST DECEMBER 13, 1996
18.80 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB CLEAN SAND SOIL TEST DONE BY J.K. HOLMGS& ASSOC.
ELEV. = WITNESSED BY P. BRYANTON
CONCRETE INSPECTION PORT
COVERS 4" SCHEDULE 40 PVC PIPE LOAM AND SEED OBSERVATION HOLE 1 ELEV.= 11'62
MIN. PITCH 1/8" PER FT. 2" LAYER OF
1/8" TO 1/2' PERCOLATION RATE < 2 MIN./INCH AT 78 INCHES
WASHED STONE
4' CAST IRON PIPE MA " AX. 13.0 MAX. OR FILTER FABRIC VENT DEPTH HORIZ TEXTURE COLOR MOTT. OTHER
510 " AX 10.75 MIN. REQUIRED 0-16" A - - SANDY LOAM 2..5YR3/2 NO
(OR EQUAL) MINIMUM
FLOW Z 16-30' B LOAMY SAND 5YR5/8
PITCH 1/4' PER FT. LEVELERS TEE 30-60" C1 COARSE SAND 5YR6/6
FLOW UNE 10.00 ° 60-120" C2 FINE SAND 5YR7/3
TTELCV_V.� 11_50 _ r WATER ENCOUNTERED AT 112_ ELEV_ = 2.29
MIN = 10.75 2'0" ° ° °;0'°
1t� GAS 6" SUMP LELEV = 9.73 EVEL° c " ELEV. = 8 87 OBSERVATION HOLE 2 ELEV.= 13.58
BAFFLE ELEV. = 9.90
DISTRIBUTION DEPTH HORIZ TEXTURE COLOR MOTT. OTHER
ELEV. _ }2 (TOTAL) HIGH CAPACITY INFILTRATORS 0-14" A SANDY LOAM 2.5YR3/2 NO
LIQUID OUTLET BOX (H-20) _ 9.sD WITH STONE IN -- ---
4DEPTH TEE FEET 14 INCHES (TO BE PLACED ON FIRM BASE) TO BE WATER TESTED , m 5 - 14-36" B LOAMY SAND 5YR5/8
5 FEET 19 INCHES 1F MORE THAN ONE OUTLET 2 - 11 X 48' X 10' TRENCH FORMATION 10 ZWELL MtONE A 29 = 36-72" Cl COARSE SAND 5YR6/5
6 FEET 24 1NCHES 1500 GALLON TO BE PLACED ON FIRM BASE)
7 FEET 29 INCHES c SOIL ABSORPTION INDEX 6.7 72-134' C2 FINE SAND 5YR7/3
8 FEET 34 INCHES SEPTIC TANK 3/4' TO 1 1/2" CLEAN , " ADJUST 0.7 WATER ENCOUNTERED AT 134" �V• = 2.41 _
(H-10) DOUBLE WASHED STONE SYSTEM (SAS)(H 20)
GUEST
�+ FREE OF FINES & SILT
GUEST HOUSE wry, r USGS PROBABLE WATER TABLE ELEV. = 3.11
SEWAGE DISPOSAL SYSTEM PROFILE OBSERVED WATEBOTTOM OFTABLE 2TEST IHOLE 996) EELEV. = �4-�2--
NDT TO SCALE GUEST HOUSE
4" SCHEDULE 40 PVC PIPE CLEAN SAND DESIGN CALCULATIONS
TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE MIN. PITCH 1/8' PER FT. INSPECTION PORT 2" LAYER OF
FOUNDATION
FT. MINIMUM FROM SLAB �pW 1/8' TO 1/2" NUMBER OF BEDROOMS 3
ELEV. - 10 FT, MINIMUM 2' PRESSURE PIPE LEVELERS WASHED STONE GARBAGE DISPOSAL UNIT NO
150 PSI MINIMUMELEV. = 13,0 M R FILTER FABRIC VENT ESTIMATED FLOW
CONCRETE 8.00 10.75 MIN. REQUIRED (110 GAL/8R./OAY X 3 BR) 33D GAL/DAY
REQUIRED SEPTIC TANK CAPACITY :36�0 GAL
COVERS MANHOLE QUICKz ACTUAL SIZE OF SEPTIC TANK 15_0_ GAL
COIR QINI�NNECT EE
&6C 4' CAST IRON PIPE " M 6' 10
.00
(OR EQUAL) MINIMUM 2.0" e a ° MAIN HOUSE
PITCH 1/4" PER FT. LEVEL to' DESIGN CALCULATIONS
ABEL 1800 FILM£may_ = 6* SUMP �ry�V. = 9.73 ° e ° ELEV. 887
10"OW LINE �I�TRIBU I ION £� = c NUMBER OF BEDROOMS 5--
EtEV - 9 GARBAGE DISPOSAL UNIT NO _
12 (TOTAL) HIGH CAPACITY INFILTRATORS ESTIMATED FLOW
-TMIN. GAS 3/8" DRILL BOX 9.50 WTH STONE IN Z 5.5 (110 GAL/8FL/DAY X 5 BR.) 550 GAL/DAY
ELEV. = 6.35 BAFFLE
HOLE
BE WATER TESTED 2 - 11' X 48' X f0' TRENCH FORMATION WELL M1W 29 REQUIRED SEPTIC TANK CAPACITY 1100 GAL
ELEV. = 8_10 (TO BE PLACED ON FIRM BASE) SOIL A SO PTfON ZONE A ACTUAL SIZE of SEPTIC TANK 1__500_ GAL
o �� E � CAPACITY OF SEPTIC TANK � GAL.
CHECK WAS D 1 1/2" SYSTEM kSAS)(H-20) ADJUST °•'
LIQUID OUTLET ^- VALVE WASHED STONE
QFPTH TEE
4 FEET 14 INCHES CTO BE PLACED ON FIRM BASE) MYERS SRM 4(H-20) SOIL ABSORPTION SYSTEM
5 FEET 19 INCHES 1500 GALLON PUMP 0.4 HP (MAX) TI
6 FEET 24 INCHES f (OR EQUAL) USGS PROBABLE WATER TABLE ELEV. = 3.11 DESIGN CALCULATIONS
7 FEET 29 INCHES SEPTIC TANK( OBSERVED WATER TABLE (12/13/1996) ELEV. = 2.41
8 FEET 34 INCHES BOTTOM OF TEST HOLE ELEV_ = 1.T62 -
(H-1 0) (H'-20) TOTALESTIMATED 0FLOW 880 GAL./DAY
MAIN HOUSE (1000 G.S.T. PUMP CHAMBER CALCULATIONS: SOIL CLASSIFICATION
DESIGN PERCOLATIN.
SEWAGE DISPOSAL SYSTEM PROFILE ELEV. AT INVERT INLET &00 REQUIRED FLOW PER CYCLE .25 X 550 = 13_7.52 GAL/CYCLE EFFLUENT LOADING RATE� _0.74_ GAL/DAY/S.F.
ELEV. AT ALARM ON 5.50 VOLUME PER CYCLE 137.5 GAL/CYCLE /7.48 GAL/CU. FT. = 18.38 CU. FT./CYCLE LEACHING AREA _
NOT TO SCALE `5_38 VOLUME OF WATER IN PIPE 3.14 X 0.00694 X ?? FT. = 1.57 CU. FT. 2 X 11X48 �� SQ
ELEV. AT PUMP ON 4.83 TOTAL MINIMUM VOLUME PER CYCLE 19 CU FT -
4.00
)+(59X2X10/12)]
ELEV. AT PUMP OFF 400 DISCHARGE 19.95 CU. FT. / 36.11 CU.FT. (1000 G.S.T.) LEACHING CAPACITY (AREA X RATE 926_97 GAL/DAY
BOTTOM OF INSIDE PUMP CHAMBER _ %T = 0
BOTTOM OF OUTSIDE PUMP CHAMBER _3_75 STORAGE CAPACITY {�` _ GAL/DAY /7.48 GAL:/CU.FT./36.11 CU.FT./FT. _ �0� FT. 125266 X 0.74
2 04_ REQUIRED _V50- PROVIDED RESERVE LEACHING CAPACITY K6-47- GAL/DAY
LEG
EXISTINI
EXISTINI
FINAL E
FINAL C
SOIL TE
UTILITY
TOWN V
CATCH
GAS LIf•
CESSPC
CLEANC
NOTES:
1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P.
TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR
THE SUBSURFACE DISPOSAL OF SEWAGE.
2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
WITHIN 6' OF FINISHED GRADE.
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE
USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS.
4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL
BE MORTARED IN PLACE.
5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH
DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO
OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.
6, UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS
PRIOR TO COMMENCING WORK ON SITE.
7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS
SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION
IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER
IMMEDIATELY.
B. PARCEL IS IN FLOOD ZONE A8 & B
9. LOT IS SHOWN ON ASSESSORS MAP 61 AS PARCEL _ 98
10. PUMP AND ALARM ARE TO BE ON SEPERATE CIRCUITS.
11. ALARM IS TO BE BOTH AUDIO AND VISUAL
12. A ZABEL A1800 FILTER IS TO BE INSTALLED.
13, AN ELECTRIC PERMIT IS REQUIRED TO WIRE PUMP AND ALARM.
14. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND
FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE
REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3).
15. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATERPROOFED AT
THE MANUFACTURER.
16, THE INSTALLER IS TO GIVE THE ENGINEER A MINIMUM OF 48 HOURS
(2 WORKING DAYS) NOTICE FOR THE FINAL INSPECTTON (NUMBER BELOW).
17. A HAYBALE AND SILTFENCE WORKLIMIT IS TO BE INSTALLED AND MAIN-
TAINED UNTIL ALL DISTURBED AREAS ARE STABILIZED AND REVEGETATED.
18. EXISTING STRUCTURES ARE ALL TO BE REMOVED WITH THE EXCEPTIONS
OF THE SHED AND SOUTHERLY PORTION OF THE MAIN HOUSE. WHICH ARE
TO BE RELOCATED AS SHOWN.
19. EXISTING SEPTIC FACILITIES ARE TO BE PUMPED AND REMOVED ALONG
WITH ANY POLLUTED SOILS ENCOUNTERED.
20. THERE IS TO BE A NEGATIVE GRADE OF AT LEAST 1/4' PER FOOT FOR
A MINIMUM OF 15' ALL AROUND THE FOUNDATION.
21. THERE ARE TO BE GUTTERS, DOWNSPOUTS AND DRYWELLS INSTALLED.
22. A VARIANCE IS REQUIRED FOR THE TOP OF FOUNDATION TO BE LESS
THAN 2' ABOVE THE HIGH POINT IN THE ROAD. (VARIANCE OF 4.0')
PUMP SWITCHES DETAIL
ALARM ON
PUMP ON
1 it PUMP OFF
CD
(I c
I RIVERFRONT LANDSCAPING
APPROVED: BOARD OF HEALTH
19mum
AGENT
i�
MA
ass.
Az
N` LOCHS
c
ePhy
PROPOSED SEPTIC DESIGN
FOR
DAVENPORT BUILDING CO.
LOC.
46 PLEASANT STREET
SOUTH YARMOUTH, MASS.
SIZEMER ENGLNXWWG
203 SETUCKET ROAD
508- P. O. BOX 713
385-6900 SOUTH DENNIS, MASS. 02660
SCALE 1 " = 20'
DATE N OV. 2, 2011
REV. NOV. 17, 2011
JOB NO. 5116-02
SAP
REv. JULY 31, 2013
SHEET 1 OF 1
i�
MA