HomeMy WebLinkAbout83-1939 - DetailsLATERALS 5' CENTER TO CENTER uiDAM IA11M FARRIC OVER STONE SEE PAVEMENT SECTION . - EL. 12.03' 0000 00 0 0°0°0°0°0°0°0°0°0°000 Dao°000 o °o° 000° / INV. EL. °°°°000 °00000 0 °0 0 2" ° o ° ° ° o °°°, ° o ° B 00 000 0000000 000°00000000000,eoo°o ° o °000 ° °00000n.000°000 ° ° °o°o°o°000 000°000000°°000°o °oo°0 6•, EL. 11.4' On.0000000°0 00000°00000 0°0°°°°0°00000°°°°°°°°°°,°° 2.0"0SCH40 PVC 8" 70TAL0OF .75" 0 1.5" STONE ORIFICE SHIELD OS200 DOUBLE WASHED ONLY ORENCO SYSTEMS INC WITH 1/4" ORIFICES DRILLED AT 5' O.C. ENGINEER TO INSPECT PH. 1-800-348-9843 OR EQUAL SEE DETAIL ALTERNATING UP AND DOWN CLEAN COMPACTED COARSE SAND FILL DRILL DISTAL END ON TOP. UNDERNEATH LEACHING FIELD NOT TO SCALE 2.0"0 SCH-40 PVC LA 3" OR 2" TEE 3" OR 2" RISER TEE . !C TO PUMP VARIES PIT SCHBO PV\' T 4"SCH 40 PVC MANIFOLD / ORIFICE SHIELD OS200 ORENCO SYSTEMS INC PH. 1-800-348-9843 OR EQUAL. HOLE AT 5' O.C. �I SNAP-ON TEST HOLE LOGS ALTERNATE BETWEEN TOP SHIELD & BOTTOM OF PIPE. -- 0 DRAINAGE SAMETER HOLES LOTS ENGINEER: DANIEL A OJALA PE. SE#1805 EXACT SHOULD IBE SHOP DRILLED WITH WITNESS. AMY VON HONE A DRILL PRESS TO ENSURE UNIFORMITY. REMOVE BURRS DATE: 4-4-2012 PRIOR TO PLACING PIPE. ORIFICE SHIELD DETAIL PERC. RATE _ < 2 MIN/INCH XOT TO SCALE CLASS SOILS APPROX. 156 ORIFI REQUIRED V.I.F. EXTERNAL auxcTTox Box. POWER CORDS SHALL BE CONNECTED TO WATERTIGHT NEMA APPROVED ELEV. CONNECTORS NOT LOCATED INSIDE ELEV. ELEV. n 12 2' THE PUMP CHAMBER. ELEV. 4 12.4 0., 13.0' 0" V 4 - 0" 12.9' p" _ A A A A LS LS LS LS 1OYR 3/2 1OYR 3/2 CLEANOUT DETAIL: LeBARON CAST IRON LA0910 H-20 RATED VALVE BOX TO GRADE AT EA. END. F1 / 2.O"OSCH40 LATERAL INV. LEVEL 4"X4" 1/4" ORIFICE IN LATERAL 60" O.C. WITH SHIELDS (TYP.) SEE PLAN FOR LOCATIONS SIDE ELEVATION VIEW 1.5 CU.FT.f 90• ELECTICAL CONDUIT SWEEP DRILL LAST ORIFICE Ot BOTTOM STONE EL. 11.4 1 DYR 3/2 10YR 3/2 12 5' 6" 11.7' (2) MYERS PUMPS ON MYERS 6" 12.2' 6" 1 1.9 6"STAINLESS STEEL RAIL MOUNT\ g IN B B B 40" X 0" BILCOSYSTEMSYH-20 HATCH LS LS LS LS 24" 1OYR 6/8 10.7' 1OYR 6/8 24„ 1OYR 6/8 11.0' 1OYR 6/8 30" 9.9' 1 30" 9.7' 4 PERC 0 40" M/CS 2.5Y 7/4 4.7' 9 6" G.W.E 120" 1 1 2.7 126" ADJUSTED GROUNDWATER @ 6.4' GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJUSTMENT: 1.7' (MARCH) C M/CS 2.5Y 7/4 4.7' C M/CS 96" 2.5Y 7/4 4 7' C M/CS 2.5Y 7/4 4.7 INSTALLER TO COORDINATE INSPECTIONS 24 HR. NOTICE REQUIRED. INSPECTIONS: PUMPINSTALLATION 6" IMPELLER DIAMETER 3.0 HP 3 PHASE, 230 VOLT 1. PUMPS SHALL BE INSTALLED IN STRICT CONFORMANCE WITH THE MANUFACTURERS SPECIFICATIONS. PRIOR TO ORDERING PUMPING EQUIPMENT AND THE INSTALLER SHALL PROVIDE THE DESIGN SHOP DRAWINGS OF THE ALL PUMPING EQUIPMENT FOR APPROVAL. INSTALLER SHALL CONFIRM THAT THE REQUIRED POWER CONFIGURATION FOR FOR THE PUMP(S) IS AVAILABLE AT THE SITE. 2. CONTROLS: PUMP CONTROLS SHALL BE LOCATED WITHIN A DESIGNATED UNIT IN AN ACCESSIBLE AREA AND SHALL BE ENCLOSED AS REQUIRED TO MEET ALL STATE AND THE PUMPS SHLL A OPERATE ALTERNATELY SO I LOCAL CODES AND REGULATIONS. THAT EACH OPERATION APPLIES THE PROPER DOSE TO THE SOIL ABSORPTION SYSTEM. PUMPS SHALL BE PROVIDED WITH A LOW LEVEL OVERRIDE AND REDUNDANT LOW LEVEL ALARM SET SUCH THAT THE PUMPS REMAIN SUBMERGED. PUMPS SHALL OPERATE FOLLOWING SEQUENCE: a. PUMPS OFF b. LEAD PUMP ON c. ALARM ON AND LAG PUMP ON (TWO PUMPS OPERATE OR ALTERNATE PUMP SUBSTITIUTES FOR FAILED PUMP) d. PUMPS MUST ALTERNATE 3. PROVIDE RUN TIME METERS AND EVENT COUNTERS IN PANEL. a. PROVIDE SEPARATE ELECTRICAL METER FOR FAST/PUMP CHAMBER. 4. ALARM: PUMPS SHALL BE EQUIPPED WITH AN ALARM POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER. THE ALARM SHALL CONSIST OF A RED WARNING LIGHT AND AUDIBLE SIGNAL WITH PRESS TO SILENCE SWITCH. THE ALARM SHALL SIGNAL A LOW WATER CONDITION (PUMPS NOT SUBMERGED) AND A HIGH WATER LEVEL CAUSED BY PUMP FAILURE, ELECTRIC PERMIT REQUIRED. 5. PROPER FUNCTION OF PUMPS, CONTROLS AND ALARMS SHALL BE DEMONSTRATED BY CLEAN WATER TESTING PRIOR TO CERTIFICATE OF COMPLIANCE BEING ISSUED. 6. INSPECTIONS REQUIRED PER TITLE 5 @ 3 MONTH INTERVALS. THE YARMOUTH BOARD OF HEALTH SHALL REQUIRE THE FOLLOWING INSPECTIONS: 17 1. INSPECTION OF UNSUITABLE MATERIAL (IF ANY). 62.4 = 2. VERIFICATION OF SOIL CONDITIONS AND/OR GROUNDWATER ELEVATION (IF NECESSARY) (OK) 3. VERIFICATION OF CESSPOOL/LEACH PIT REMOVAL OR ABANDONMENT (IF NECESSARY) LOW �� 5000 5. INSPECTION OF THE 3/4 - 1 1/2 INCH STONE PRIOR TO PLACEMENT 60.920 LBS 6. FINAL INSPECTION OF ALL COMPONENTS PRIOR TO BACKFILLING 17 �d T x 62.4 B. INSPECTION OF THE START-UP OF INNOVATIVE/ALTERNATIVE TECHNOLOGY (IF ANY) (OK) WITH VENDOR REPRESENTATIVE RISL�S (TVP.) �o - INSTALLER TO COORDINATE INSPECTIONS 24 HR. NOTICE REQUIRED. INSPECTIONS: PUMPINSTALLATION 6" IMPELLER DIAMETER 3.0 HP 3 PHASE, 230 VOLT 1. PUMPS SHALL BE INSTALLED IN STRICT CONFORMANCE WITH THE MANUFACTURERS SPECIFICATIONS. PRIOR TO ORDERING PUMPING EQUIPMENT AND THE INSTALLER SHALL PROVIDE THE DESIGN SHOP DRAWINGS OF THE ALL PUMPING EQUIPMENT FOR APPROVAL. INSTALLER SHALL CONFIRM THAT THE REQUIRED POWER CONFIGURATION FOR FOR THE PUMP(S) IS AVAILABLE AT THE SITE. 2. CONTROLS: PUMP CONTROLS SHALL BE LOCATED WITHIN A DESIGNATED UNIT IN AN ACCESSIBLE AREA AND SHALL BE ENCLOSED AS REQUIRED TO MEET ALL STATE AND THE PUMPS SHLL A OPERATE ALTERNATELY SO I LOCAL CODES AND REGULATIONS. THAT EACH OPERATION APPLIES THE PROPER DOSE TO THE SOIL ABSORPTION SYSTEM. PUMPS SHALL BE PROVIDED WITH A LOW LEVEL OVERRIDE AND REDUNDANT LOW LEVEL ALARM SET SUCH THAT THE PUMPS REMAIN SUBMERGED. PUMPS SHALL OPERATE FOLLOWING SEQUENCE: a. PUMPS OFF b. LEAD PUMP ON c. ALARM ON AND LAG PUMP ON (TWO PUMPS OPERATE OR ALTERNATE PUMP SUBSTITIUTES FOR FAILED PUMP) d. PUMPS MUST ALTERNATE 3. PROVIDE RUN TIME METERS AND EVENT COUNTERS IN PANEL. a. PROVIDE SEPARATE ELECTRICAL METER FOR FAST/PUMP CHAMBER. 4. ALARM: PUMPS SHALL BE EQUIPPED WITH AN ALARM POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER. THE ALARM SHALL CONSIST OF A RED WARNING LIGHT AND AUDIBLE SIGNAL WITH PRESS TO SILENCE SWITCH. THE ALARM SHALL SIGNAL A LOW WATER CONDITION (PUMPS NOT SUBMERGED) AND A HIGH WATER LEVEL CAUSED BY PUMP FAILURE, ELECTRIC PERMIT REQUIRED. 5. PROPER FUNCTION OF PUMPS, CONTROLS AND ALARMS SHALL BE DEMONSTRATED BY CLEAN WATER TESTING PRIOR TO CERTIFICATE OF COMPLIANCE BEING ISSUED. 6. INSPECTIONS REQUIRED PER TITLE 5 @ 3 MONTH INTERVALS. THE YARMOUTH BOARD OF HEALTH SHALL REQUIRE THE FOLLOWING INSPECTIONS: 17 1. INSPECTION OF UNSUITABLE MATERIAL (IF ANY). 62.4 = 2. VERIFICATION OF SOIL CONDITIONS AND/OR GROUNDWATER ELEVATION (IF NECESSARY) (OK) 3. VERIFICATION OF CESSPOOL/LEACH PIT REMOVAL OR ABANDONMENT (IF NECESSARY) LOW 4. INSPECTION OF CONTAINMENT WALL OR FLOW BARRIER INSTALLATION (IF ANY) 5000 5. INSPECTION OF THE 3/4 - 1 1/2 INCH STONE PRIOR TO PLACEMENT 60.920 LBS 6. FINAL INSPECTION OF ALL COMPONENTS PRIOR TO BACKFILLING 17 7. FINAL GRADING INSPECTION x 62.4 B. INSPECTION OF THE START-UP OF INNOVATIVE/ALTERNATIVE TECHNOLOGY (IF ANY) (OK) WITH VENDOR REPRESENTATIVE RISL�S (TVP.) 9. OWNERS ENGINEER TO INSPECT THE DOUBLE WASHED STONE TO ENSURE IT IS FREE OF DUST AND FINES. - 10. ENGINEER TO INSPECT THE SHOP DRILLED ORIFICES TO ENSURE BURRS HAVE BEEN REMOVED FROM LATERALS, 2'0 11. PROPER FUNCTIONING OF THE PUMPS, CONTROLS AND ALARMS SHALL BE DEMONSTRATED BY CLEAN WATER ER TESTING PRIOR TO BACKFILLING THE SAS FIELD. 2" RECYCLE LINE 12. CERTIFIED AS -BUILT PLAN WITH INVERT ELEVATIONS AND FIELD LOCATION IS TO BE PREPARED FOR THE TOWN BY THE OWNERS ENGINEER. PRIOR TO ANY ALUMINUM HATCH 2% SLOPE REQUIRED OVER SYSTEM l0 40"X30' OPENING HATCH TO BE SET IN PRECAST 3' PUMP REINFORCED CONCRETE RISER QUOTE ADDRIORD REMOVE/REPLACE AT COST PUMP RAIL AND DISCONNECT FOUNDATION- 1 g6' FEMALE ADAPT( SETTINGS: SCH d(� BRACE 4"SCHBO PVC PIPE FACILITY � INSIDE PUMP CHAMBER AS REQ. i ALUMINUM HATCH 40" X 30" SPECIFICATIONS: BILCO OR EQUAL COVER SHALL HAVE AN ANGLE FRAME WITH A 40" X 30" RECTANGULAR OPENING CONCRETE MINIMUM STRENGTH: 5000 PSI AT 28 DAYS PLAN VIEW AND HAVE A HINGED COVER OF NON-SKID PATTERN. HINGED COVER SHALL HAVE ASTM -AS -615 GRADE 60 A HOLD OPEN BAR THAT CAN BE LOCKED IN THE OPEN POSITION. COVER SHALL HAVE A LOCK STEEL REINFORCEMENT: DESIGN LOADING: HS -20 THAT USES A KEY OR SPECIAL INSERT TO OPEN AND IS LOCKABLE. COVER TO BE OF ALUMINUM. ACME PRECAST OR SHOREY PRECAST OR EQUAL. RAIL GUIDE SUPPORT PLATE TO BOLT TO THE HATCH COVER FRAME. CONTRACTOR TO VERIFY THAT ALL SEPTIC TANKS TO LEACHING SURFACE BELOW FRAME MUST BE SMOOTH AND NOT PROTRUDE INTO FRAME OPENING. HATCH TO BE SIT IN A CUSTOM POURED PRECAST CONCRETE BASE. ALLOW FOR A AND THE PUMP CHAMBER ARE 1007. WATER TIGHT. PUMP RAIL SUPPORT TO FRAME OF HATCH WHEN POURING CONCRETE. TTACHMENT OF ENGINEER TO INSPECT 24 HR LEAK TEST WRAP REBAR CONTINUOUS AROUND HATCH FRAME TO RESIST LATERAL LOADS FROM TRAFFIC OVER HATCH. ALL HARDWARE INSIDE PUMP CHAMBER TO BE STAINLESS STEEL. ALUMINUM HATCH 40" X 30" RIM ELEV. 9.93 V.I.F. ' I STAINLESS STEEL BILCO H-20 OR EQUAL 1.9' 120" 1 I 3_0 126" I I 1.7' LIFTING CHAINS SET IN PRECAST REINFORCED CONCRETE RISER, LLQ-» GALVANIZED CHAINS WILL BE WITH (4) #4'S CONTINUOUS AROUND MIN. REJECTED BY OWNERS ENGINEER. BUOYANCY CALCS: NOTE: SEPTIC SYSTEM COMPONENTS ARE IN H-20 LOW PROF. 7000 GAL. ST WEIGHS 71.4..o 0 LBS GROUNDWATER SHORING OF 6.12' x 17 x 10 X 62.4 = 64,956 LBS UP (OK) EXCAVATION/DEWATERING MAY BE REQUIRED. H-20 3000 GAL. ST WEIGHS 36,000 LBS RESPONSIBILITY OF CONTRACTOR TO MAINTAIN PUBLIC AND BUILDING SAFETY. 1.4' x 17 x 7 x 62.4 = 10,396 LBS UP (OK) H-20 LOW PROF. 5000 GAL. PC WEIGHS 60.920 LBS 3.73 x 17 x 10 x 62.4 = 39,566 LBS CP (OK) ELECTRIC PANELS FOR I5' MIN PUMPS BUILDING NEAR EXIST. PANELS. - PPO' r0_ � INSa T P RT TO GRADE & MATCH PAVEMENT CONTRACTOR TO ACCESS COVERS TO FIN. GRADE .EC DN 0 ACCESS COVERS TO FIN. GRADE \ SLAB EL. 14.0 MINIMUM .75' OF COVER OVER PRECAST 10.0' MINIMUM .75' OF COVER OVER PRECAST I BUILDING •' 4"SCH40 PVC H-20 CAST IRON COVER PRECAST H-20 PRECAST fl -20 INVERT ®206 '510 ELECTRIC PERMIT REQ. FROM TOWN. f.•_• -r,: J.. RISERS (TVP.) RISL�S (TVP.) RUN 1.2R -":' - ALUMINUM HATCH 2'0 2't ER VERIFY INVERTS IN FIELD - 2" RECYCLE LINE COMPARAB'E MEANS FOR FUTURE LOCATION. 0( DUPLEX1 INVERT 10' RUN 92 4"® 1.59 . Ex 2ABOVE PRIOR TO ANY 10 FROM P/C TEE END COORDINATE WITH FAST TEE 24" 2% SLOPE REQUIRED OVER SYSTEM 1o" WASTE II TEE 24" (MIN. 3 - ELECTRIC PANELS FOR I5' MIN PUMPS BUILDING NEAR EXIST. PANELS. - PPO' r0_ � INSa T P RT TO GRADE & MATCH PAVEMENT INVERT Io' 8.88 RUN 52 4100 2.77. ' .' CONTRACTOR TO TEE .EC DN 0 CHAMBER OR COMPACTION. [2]) 3000 GAL.SIZE) ACTION � 1�� PROVIDE ALL REQUIRED 5' REMOVAL OF UNSUITABLE SOILS REQUIRED. OUTLET � REMOTE CONDUITS AND CABLES. H-20 CAST IRON COVER 1 / BLOWER ELECTRIC PERMIT REQ. FROM TOWN. 40" X 30" H-20 ALL SYSTEM COMPONENTS SHALL BE .36' LOCATION PER - ALUMINUM HATCH MARKED WTH MAGNETIC TAPE OR p ER VERIFY INVERTS IN FIELD - COMPARAB'E MEANS FOR FUTURE LOCATION. 0( 8.33' PRIOR TO ANY FLOAT 8.08' 2% SLOPE REQUIRED OVER SYSTEM 2 O rq�, BA'P CONSTRUCTION 3' PUMP 10 D• i QUOTE ADDRIORD REMOVE/REPLACE AT COST 5" VENe' FOUNDATION- 1 g6' 10" TEE USE H-20 INTERNAL SETTINGS: .� ' L=�L FACILITY PER CUBIC YARD IN CASE REQUIRED. CONSTRUCTION (LONGEST RUN) (_1_7 SLOPE) (--L-7 MOUNT TANK ALARM ON INSPECTION PORT DETAIL SCH.80 PRESSURE UNEN SYSTEM PROFILE SCALE 1"= 0 73" PUMP ON " 6B (NOT TO SCALE) 0000000 000o 0000000 0 o 0 000 0o 00 0 ,ARcS INVERT Io' 8.88 RUN 52 4100 2.77. ' .' PROPOSED TEE I■I CHAMBER OR COMPACTION. [2]) 3000 GAL.SIZE) ACTION � 1�� TEE 5' REMOVAL OF UNSUITABLE SOILS REQUIRED. OUTLET � I • MIN WATERPROOF/WATERTIGHT 1 VIL. .F?67 5000 GAL. P/C .63' ELEV.'S VARY !BLAND .36' k SWITCH DUPLEXJ3,,7. INVERT�. 6JM UNSUITABLE MATERIAL MAY VARY, ENGINEER TO INLETS FROM SEWERS CAS BAFFLE - 8.61' OAS BAFFLE (15.221 2) - [ ] 8.33' '0 FLOAT 8.08' 1 , 2 O rq�, BA'P 3' PUMP 315' QUOTE ADDRIORD REMOVE/REPLACE AT COST PRIOR TO ANY FOUNDATION- 1 g6' 10" TEE USE H-20 INTERNAL SETTINGS: .� ' J FACILITY PER CUBIC YARD IN CASE REQUIRED. CONSTRUCTION (LONGEST RUN) (_1_7 SLOPE) (--L-7 MOUNT TANK ALARM ON INSPECTION PORT DETAIL " SYSTEM PROFILE SCALE 1"= 0 73" PUMP ON " 6B (NOT TO SCALE) 0000000 000o 0000000 0 o 0 000 0o 00 0 8" WORKING NOTE: CONTRATOR TO VERIFY 0000000 0000 00000000000 00000000000 0000 OOOO RANGE ALL PIPES CE CONNECTED OR MECHANICAL OR - _ , °°3.0 _ _0_0_°„ E4%ooage=_e">'o eS..o"._ _0_0_ ° °°6'"CRUSHED^STONE PUMP OFF 25° 6" CRUSHED STONE BY GRAVITY TO ELEVATIONS LISTED PRIOR TO SETTING ANY TANKS. COMPACTION. (15.221 [2]) MICROFAST°WITHIN ` LVALVED CONNECTOR BETWEEN PUMP LINES 5 BALL VALVES IN H CONFIGURATION ON CENTER VALVE NORMALLY CLOSED �A.OJ. GW 0 6.4 C-}. GNCGL W1}-VLS OBS. GW C 4.7 MAY BE LOWER AT TANKS DUE TO PROXIMITY TO TIDAL WATER) s A R & THREADED PLUG 0 PVC BOTH E.NDS)L-� NOTES 2. MUNICIPAL WATER IS EXISTING (REDO) 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-20 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH, 40-4" PVC WHERE NOT SPECIFIED. PRESSURE DOSING PIPE- SEE PLAN. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED WHERE INTERFERES WITH -PROPOSED FIELD AND OVERDIG, REMOVE ALL OLD COMPONENTS PER T5 CODE. a � LEACHING FIELD 1n a w 4"0 SCH40 PVC MANIFOLD PITCH .005 FT/FT MIN. 5.00' 0 w U 0 0 .113 w U 0 0 > a 1 1 I I 0 x U N INSPECTION PORT SEE DETAIL ELEVATIONS VARY OV R NEW LEACHING, APPROX. EL 13.0 - 13.8 \ SAWCUT AND PATCH, MATCH EXISTING GRADES TDP FABRIC SEE PAVEMENT SECTION NOTE: FLAT GRADES. CAREFUL GRADING REQUIRED. / INVERT OF 2.0" LATERALS LEVEL AT EI ELEV. 9.7-11.0 V.I.F. BOTTOM STONE EL. 11.4' BOTTOM OF REMOVAL TO ELEV. 9.7-11.0 SEE LOGS, DEPTH MAY VARY WITH THE ORIGINAL GROUND SURFACE ELEVATION. ENGINEER TO INSPECT SOIL REMOVAL. REPLACE WITH CLEAN MEDIUM SAND 310CMR 15.255 (3). QUOTE ADDITIONAL MATERIAL REMOVE AND REPLACE AT COST PER CUI PROPOSED 7000 GAL. ST1 I■I CHAMBER OR COMPACTION. [2]) 3000 GAL.SIZE) ACTION � 1�� o b o �� '` V.I.F. 5' REMOVAL OF UNSUITABLE SOILS REQUIRED. INVERT � I • MIN WATERPROOF/WATERTIGHT 1 VIL. .F?67 5000 GAL. P/C REMOVE TO THE BOTTOM OF THE UNSUITABLE LAYER SHOWN ON TEST HOLE LOGS. THE DEPTH OF FILL AND ELEV.'S VARY !BLAND RD LVALVED CONNECTOR BETWEEN PUMP LINES 5 BALL VALVES IN H CONFIGURATION ON CENTER VALVE NORMALLY CLOSED �A.OJ. GW 0 6.4 C-}. GNCGL W1}-VLS OBS. GW C 4.7 MAY BE LOWER AT TANKS DUE TO PROXIMITY TO TIDAL WATER) s A R & THREADED PLUG 0 PVC BOTH E.NDS)L-� NOTES 2. MUNICIPAL WATER IS EXISTING (REDO) 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-20 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH, 40-4" PVC WHERE NOT SPECIFIED. PRESSURE DOSING PIPE- SEE PLAN. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED WHERE INTERFERES WITH -PROPOSED FIELD AND OVERDIG, REMOVE ALL OLD COMPONENTS PER T5 CODE. a � LEACHING FIELD 1n a w 4"0 SCH40 PVC MANIFOLD PITCH .005 FT/FT MIN. 5.00' 0 w U 0 0 .113 w U 0 0 > a 1 1 I I 0 x U N INSPECTION PORT SEE DETAIL ELEVATIONS VARY OV R NEW LEACHING, APPROX. EL 13.0 - 13.8 \ SAWCUT AND PATCH, MATCH EXISTING GRADES TDP FABRIC SEE PAVEMENT SECTION NOTE: FLAT GRADES. CAREFUL GRADING REQUIRED. / INVERT OF 2.0" LATERALS LEVEL AT EI ELEV. 9.7-11.0 V.I.F. BOTTOM STONE EL. 11.4' BOTTOM OF REMOVAL TO ELEV. 9.7-11.0 SEE LOGS, DEPTH MAY VARY WITH THE ORIGINAL GROUND SURFACE ELEVATION. ENGINEER TO INSPECT SOIL REMOVAL. REPLACE WITH CLEAN MEDIUM SAND 310CMR 15.255 (3). QUOTE ADDITIONAL MATERIAL REMOVE AND REPLACE AT COST PER CUI DCE #02-256 o o 400 CAPACITY - GPM PUMP CURVE FOR EFFLUENT PUMPS . 11.9' \ 4" CENTRAL FED MANIFOLD 11.0t PITCH TO DRAIN BACK TO P/C PROPOSED 7000 GAL. ST1 PROPOSED 5000 GAL. ST2 CHAMBER OR COMPACTION. [2]) 3000 GAL.SIZE) ACTION /$�o�°a$��� � a o b o �� '` V.I.F. 5' REMOVAL OF UNSUITABLE SOILS REQUIRED. INVERT H-20 LOW PROFILE H-20 LOW PROFILE MIN WATERPROOF/WATERTIGHT / PROPOSED VIL. .F?67 5000 GAL. P/C REMOVE TO THE BOTTOM OF THE UNSUITABLE LAYER SHOWN ON TEST HOLE LOGS. THE DEPTH OF FILL AND ELEV.'S VARY !BLAND RD 6" CRUSHED STONE OR MECHANICAL H-20 LOW PROFILE UNSUITABLE MATERIAL MAY VARY, ENGINEER TO SEE PLAN - COMPACTION. (15.221 2) - [ ] LEACHING INSPECT AND CERTIFY THE REMOVAL. VERIFY IN FIELD Q 2 O rq�, BA'P 3' PUMP 315' QUOTE ADDRIORD REMOVE/REPLACE AT COST PRIOR TO ANY FOUNDATION- 1 g6' SEPTIC TANK 2' SEPTIC TANK 3' MICROFAST TANK J FACILITY PER CUBIC YARD IN CASE REQUIRED. CONSTRUCTION (LONGEST RUN) (_1_7 SLOPE) (--L-7 SLOPE) INSPECTION PORT DETAIL SYSTEM PROFILE SCALE 1"= 0 MANHOLE COVER SEE DETAIL (NOT TO SCALE) DCE #02-256 o o 400 CAPACITY - GPM PUMP CURVE FOR EFFLUENT PUMPS . 11.9' \ 4" CENTRAL FED MANIFOLD 11.0t PITCH TO DRAIN BACK TO P/C MORTAR ALL COMPONENTS (TYP.) 30 Lu N 24" I.D. PRECAST CONC. RISER IF REQ. . //4'0 PRECAST DONUT 1" OVER FIELD LL / 4" THICK 4000 PSI CONC. W/WWF LLJ 18"0 OBSERVATION HOLE IN CTR. !BLAND RD �e Z 20 LEACHING FIELD - o �OG c_;' Q 2 O rq�, BA'P w 12" PERF. HDPE _ PUMP OUT WELL J 10 TO SAND AT BOTTOM FIELD F INSPECTION PORT DETAIL NOT TO SCALE MAP SCALE 1"= 0 DCE #02-256 o o 400 CAPACITY - GPM PUMP CURVE FOR EFFLUENT PUMPS . 11.9' \ 4" CENTRAL FED MANIFOLD 11.0t PITCH TO DRAIN BACK TO P/C PLAN VIEW PIPING DETAIL NOT TO SCALE PITCH .005 FT/FT MIN. 4" TO PUMP PIT czi,, a 0 0 12'03 1 CLEANOUTS SEE DETAILS USE ADJUSTED GROUNDWATER EL. 6.4 NGVD29 C YARD IN CASE REQUIRED. 1.7 ADJ. OBSERVED GROUNDWATER EL. 4.7- NOTE- CLOSE TO TIDALLY INFLUENCED, BUT FULL ADJUSTMENT USED DETAIL IN WEST YARMO PREPARED FOR UTH, MA CHARLES WHITE MANAGEMENT i;V/ ANIF A r b n {VIv o� 01^14 /f�'tfJ �'�w off 508-362-4541 I c (.-4PUL•2c ^+1,. I _ fax 508-362-9880 I aA \Aw�(},t I �" ��,I,� downcope.com �o\ s� ,ez: ak 1 `4FS down cope engineering, Inc. civil engineers IgII ` land surveyors ^` 939 Main treet ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOU7�PORT MA 02675 DATE: SEPTEMBER 18, 2012 REVISED: NOVEMBER 29, 2012 REVISED: DECEMBER 17, 2012 (WILL, NATIVE PLANTINGS PER CONCOM APPROVAL) REVISED: FEBRUARY 28, 2013 (HEALTH COMMENTS) REVISED: MARCH 29, 2013 (PB COMMENTS) REVISED: APRIL 8, 2014 (LOT 1) SHEET 4 OF 5 02-256 CHS WHT 2014.DWG Lu N 2z !BLAND RD �e Ld �OG c_;' m LOCUS 2 O rq�, BA'P MILL �Q CREEK LOCUS MAP SCALE 1"= 1000' PLAN VIEW PIPING DETAIL NOT TO SCALE PITCH .005 FT/FT MIN. 4" TO PUMP PIT czi,, a 0 0 12'03 1 CLEANOUTS SEE DETAILS USE ADJUSTED GROUNDWATER EL. 6.4 NGVD29 C YARD IN CASE REQUIRED. 1.7 ADJ. OBSERVED GROUNDWATER EL. 4.7- NOTE- CLOSE TO TIDALLY INFLUENCED, BUT FULL ADJUSTMENT USED DETAIL IN WEST YARMO PREPARED FOR UTH, MA CHARLES WHITE MANAGEMENT i;V/ ANIF A r b n {VIv o� 01^14 /f�'tfJ �'�w off 508-362-4541 I c (.-4PUL•2c ^+1,. I _ fax 508-362-9880 I aA \Aw�(},t I �" ��,I,� downcope.com �o\ s� ,ez: ak 1 `4FS down cope engineering, Inc. civil engineers IgII ` land surveyors ^` 939 Main treet ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOU7�PORT MA 02675 DATE: SEPTEMBER 18, 2012 REVISED: NOVEMBER 29, 2012 REVISED: DECEMBER 17, 2012 (WILL, NATIVE PLANTINGS PER CONCOM APPROVAL) REVISED: FEBRUARY 28, 2013 (HEALTH COMMENTS) REVISED: MARCH 29, 2013 (PB COMMENTS) REVISED: APRIL 8, 2014 (LOT 1) SHEET 4 OF 5 02-256 CHS WHT 2014.DWG