HomeMy WebLinkAbout83-1939 - Details 2UNDISTURBED
/SIDE OF TRENCH
V B" WATER MAIN
/ GRAVEL \
L. 8" WATER MAIN
illll ,
II UNDISTURBED / \
N - SIDE OF TRENCH '
:III— .• • \ � r .• . '•
-III U GRAVEL '
ILII -
-II -
II,�I II � 12" _ III I--' ' .. •.. ..
CONCRETE THRUST BLOCK ——III
2000 PSI MIN. "IIII=111 liiitllllDi IIIA
SECTION VIEW OR UTILIZE EQUIVALENT 24"
PRECAST THRUST BLOCKS
APPROVED BY DISTRICT
PLAN VIEW
THRUST BLOCK
FOR 45 AND 22.5 DEC BENDS
NOT TO SCALE
31
3' M. ACER RUBRNI
OR APPROVED 3' CAL
ALTERNATIVE
b
A—A
LeBARON LF248-2 OR EQ.
RENFORCED NEW BUCK RUR
HOSE (1/2' ID)
4 -FLANGE
DOLBLE STRAND 12 CA
MINIMUM GRATE WEIGHT:
GA V ANNEALED TWISTED WIRE
LBS.
TREE WRAP. LAP ENDS DOWN
255
DO NOT STAPLE
FRAME
3 STAKES EWALLY SPACED
GRATE
MOUND TREE 2 1/242 1/7.10'
1'1 = 11-
SPACED 1'-0' FROM TRUNK,
STAINED DARK BROWN.
Z
STAKES DRIVEN Al ANGLE AND
12" PIPE FROM
PULED VEROCAL WH WIRE
/
MIN 4'-0' BURIED
10
'-"
MIN 3' DEEP SAUCER
MIN
AND MIRAFI 140NS
i
/-3' DEPM SHREDDED BUtK MULCH
CRAM3ERS
REMOVE BURIAP FROM TCP
A I r
HALF OF W�I
.,! II� •.. COMPACTED sU B CRADE
.vA o�cc
SOIL MIK
TREE PLANTING DETAIL
SAVE EXISTING 4" CALIPER TREES OR
PLANT 3" CALIPER TREES AT 20' O.0
AROUND ENTIRE PERIMETER OF
COMMERCIAL LOT
SLOPE 0.5% MIN. (TRENCHES LEVEL)
V1
PERF. ADS -N-12- PLUS CUT -W
SLOTS WITH SKILL SAW E.O. RIB
OR PURCHASE SLOTTED PIPE Q
MIRAFI 140N TOP AND SIDES LT SECTION A -A
o�ooc w=0°o0do'
10 oc2^
"=00oH0o aoC0oooHp0g=oD
=0'0Poo
Eo o•0q
°oP°0 IUoo
PoE
o
-
I'°.. 1'.-
:I
'
2 1.5
INV. LISTED
z A 3
3/4" - 1 1/2"
H WASHED STONE UNDERNEATH
0 AND BESIDE PIPE
/ WIDTH AND LENGTHS LISTED
ADJ. G.W.
DRAINAGE CROSS SECTION
NOT TO SCALE
4 1/2"
SECTION
A—A
LeBARON LF248-2 OR EQ.
SV \
MINIMUM FRAME WEIGHT:
4 -FLANGE
- 295 LBS.
MINIMUM GRATE WEIGHT:
215
LBS.
PASS AREA:
255
SQ. IN.
FRAME
AND
GRATE
1'1 = 11-
0"
6" LOAM AND SEED OR WOODCHIPS
ON ALL DISTURBED AREAS (TYP.)
/ 3:1 MAX. CUTMAX. CUT Il SHOULDER
3:1 MAX FILL
8" WATER MAIN
SEE PAVEMENT SECTION
0
WIDTH VARIES (SEE PLAN)
1.5" TOP, 2.5" BINDER ROLLED THICKNESS
CLASS 1 BITUMINOUS CONCRETE
12" CC BERM MASS DPW M3.11.03 BERM
12" PROCESSED GRAVEL M1.03.1 SPEC.
30" MIN NON -FROST SUSCEPTIBLE MATERIAL
REPLACE ANY UNSUITABLE MATERIAL W/ MEDIUM SAND
(<10% BY WEIGHT PASSING #200 SIEVE)
GAS COMPACT SUBGRADE
0
SEWER MAIN (NOT APPLICABLE)
TYPICAL SECTION THRU ROADWAY
C.I. RING & COVER
EXTEN5
FINISH COURSE pROP.H-20 F&G 12"
MASS 2' X 2' GRATE
PW
TYPE II1
\ LeBARON LF248-2 OR EQ.
6' � D
e
/ADJUSTING COURSES AS RE
MORTAR ALL COMPONENTS (I
BINDER COURSE
I
BED FRAME IN FULL 12' X 12"
CONCRETE COLLAR FLUSH
WITH BASE COAT ASPHALT
3000 PSI CLASS I MIN.
COLLAR DETAIL
NOT TO SCALE
4 /2"
13:1 MAX FILL
3:1 MAX. CUT
ELEC., TEL, CATV. CONDUIT
LEBARON LA0910 OR EQ. OVER SEE PAVEMENT SECTION
CLEANOUT/INSPECTION PORT TO GRADE. \
1 REQUIRED PER TRENCH
- 4 -LOAM &SEED
ALL DISTURBED AREAS (TYP.)
8" H-20
F&C
SV \
2 CU FT
\\\\
CONC.
TRENCH LENGTH VARIES, SEE PLAN VIEW
SHORT LENGTH
OF
Z
12" PIPE FROM
2" MIN. PEASTONE
/
C5
BASIN TO
AND MIRAFI 140NS
( I
1 1DDLE (2) 1"0 Q
CRAM3ERS
FABRIC OVER TRENCH
A I r
Il 11HOLE
1
.vA o�cc
i
C.B. TRAP
12"0 HDPE PIPE
PROPOSED
600 GALLON PRECAST
H-20 CATCH BASIN
4' MIN. SUMP
6'0X5' SHOREY SOLID
BASIN H-20 OR EQUAL
WATER TOLERANT 2"HARDWOOD BARK
PLANTS- MUSTMULCH BETWEEN POOLING ZONE -
TOLERATE DROUGHT °g PLANTINGS DEPTH PER PLAN
LINE AND GRADE
CONDITIONS AS [ ENTRANCE SWALE
WELL. G, 4 L•a FLARED END PER PLAN VIEW AS NOTED
SECTION OVERFLOW
., ASPHALT SLOPE
OUTLET/LEACHING
FILTRATION ZONE.�" TRAPROCK/SWALE PROTECTION/FABRIC
24" PLANTING PER PLAN VIEW �DENTRANCES WITH UNDER. FIELD
MEDIUM FINISH GRADE FILTER FABRIC ADJUST AS
SOIL MATRIX REQ: UNDER REQ. TO AVOID
AS SHOWN ON
50% MEDIUM SAND ;� EROSION AND AS
30% NATIVE TOPSOIL � GRADING PLAN DIRECTED BY
20% COMPOSTa ) ENGINEER.`
USE ONLY ro
HARDWOOD
BARK MULCH \' DO NOT CONSTRUCT
NOTE: 36" DEEP�,� _ MULCHED RETENTION
12 OH -20 HDPE PIPE \ \ BASINS UNTIL
SOIL WHERE TREES s - o - / REMAINDER OF SITE IS
PROPOSED.
N STABILIZED. EXCAVATE
AREAS FOR
RECHARGE ZONE\/�\/�\j\ . '. _ \\�\\�\�; CONSTRUCTION PERIOD
COARSE SAND OR STORMWATER
GRAVEL/\\\�/\\�/j�/j\\�//\\\��':�^z;: `•-..,`�'�\\/
ANY CONSTRUCTION
TO
FINAL PLANTING
NOTE: REMOVE TOPSOIL & SUBSOIL FOR 3' ALL AROUND DRAINAGE LEACHING
WHERE REQUIRED & REPLACE WITH MEDIUM/COARSE SAND (TYP.)
RAIN GARDEN
W/ OVERFLOW PIPE
NOT TO SCA' -E
DCE #02-256
A
STORMTECH SC -310 CHAMBERS IN TRENCH CONFIGURATION
LEVEL BETWEEN STRUCTURES
SET IN WASHED STONE, SEE SECTION
REMOVE ANY SUBSOIL OR UNSUITABLE MATERIAL BENEATH
AND FOR 2' LATERALLY AROUND LEACHING & REPLACE
WITH COARSE SAND (NP.)
SECTION THRU DRAINAGE
NOT TO SCALE
1/2" EXP JOINT APPROXIMATELY 24'-0" OC
1/2" EXP JOINT WHEN ADJACENT FILLER CUT BACK 1/2-,W/ 1/2" DIA x12" LONG
TO CONC STRUCTURE OR BLDG SMOOTH EXP DOWELS AT 2'-0" OC, ONE-
CONTINUOUS SEALANT HALF GREASED
PREMOLDED F=R -6*
TROWEL ALL EDGE
-6" WIDE
B" H-20 F&C
12" X 3"
CCBERM WHERE INDICATED (FORMED INTEGRAL WITH TOP COAT ASPHALT)
/ 7.5" TOPCOAT MASS DPW
TYPE 11
2.5" BINDER BITUMINOUS
PAVEMENT
�i (THICKNESS AFTER COMPACTION)
EXTEND GRAVEL 12" MIN. / \ 12" PROCESSED GRAVEL COA
PAST EDGE PAVE MDPW M1.03.1 SPEC. VIB. ROLLER
(EXTEND GRAVEL 5' MIN. AT ROADWAY AREAS) REMOVE TOP 'S'
SUBSOIL
COMPACT SUBGRADE
NOTE: REMOVE FROST SUSCEPTIBLE MATERIAL
TO A DEPTH OF 36" BELOW FINISHED GRADE.
REPLACE WITH NON FROST SUSCEPTIBLE MATERIAL
(MEDIUM SAND W/LESS THAN 10% PASSING #200 SIEVE)
PAVEMENT CROSS SECTION
NOT TO SCALE
MUELLER SUPER CENTURION 250 OR APPROVED DEPT. EQUAL.
ROTATE HYDRANT
AS REQUIRED
STERNBERG FIXTURE: E26OLED/CA/3ARC45 T5 PM ML FHD DB
13"
STERNBERG LED ARCHITECTURAL LUMINAIRES
E26OLED WITH 150W EQUIV. LED LAMP
DARK BRONZE FINISH
IN (2) 6" LIFTS LED ROOF MOUNTED
TED TO 95% MAX. DENSITY MOD. OPEN BODY
;TOR PER ASTM -1557 METHOD D "
11
19"
HYDRANT TO BE ADJUSTED
TO GRADE AS REQUIRED,
ROTATE AS NECESSARY
FINISH GRADE
4" POST SLIP FIT
DARK BRONZE FINISH
POLE 550T 14' HIGH TAPERED POLE
+2' BASE = 16' FIXTURE HEIGHT
TELESCOPING CAST IRON
VALVE BOX BOX AND COVER
UNDISTURBED BUFFALO OR EQUAL
SIDE OF TRENCH
m
Z
6" GATE VALVE � o
STAINLESS A TURN LEFT
ONLY .n
VALVE ANCHORING TEE
il- 8"X6" TO OPEN
_ CONCRETE BACKING
VIII e AGAINST UNDISTURBED
_ MATERIAL
Illi 24" DIA. CONC. BASE 24" REVEAL
- ALL FITTINGS MECHANICAL
-III-I, 8"WATER JOINT
II,i III MAIN 6"0 TO HYDRANT FLA STONE
OR ONCRETE
CONCRETE THRUST BLOCK
18" X 18" MIN.
OR UTILIZE EQUIVALENT ROVIDE 4 CU. FT. OF SCREENED STONE
PRECAST THRUST BLOCKS - (3/4"-1.5") BACKFILL TO AT LEAST 6" CONDUIT AND ANCHOR BOLT
APPROVED BY DISTRICT ABOVE DRAIN HOLES - POSITION TO BE OBTAINED
TYPICAL HYDRANT CONNECTION FROM LIGHTING MFG.
NOT TO SCALE 2' 24"0 BASE 8' LONG
2' REVEAL
NOTE: AT END OF WATER MAIN, PROVIDE CAP + 2" TAP AND BLOW OFF, FIELD GASKET TAP, UTILIZE MEGALUGS, ASTM A-79 GRADE 60
PROVIDE 2" PLASTIC LINE TO AREA SHOWN WITH 2" SHUTOFF, SWEEP 2" LINE TO GRADE INSIDE A VALVE BOX. STEEL REINF. 1" MIN COVER
CEMENT LINED DUCTILE IRON WATER MAIN- ALL COMPONENTS TO YARMOUTH WATER DEPT. SPECIFICATIONS. 5' (4) #6'S VERTICAL MIN,
SDDD PSI MIN CONCRETE
TYPICAL LIGHT POLE
2" RIGID GALVANIZED
NOT TO SCALE STEEL SWEEP
SEE PAVEMENT SECTION #3 STIRRUPS AT 12"O.C.
8" H-20 F&G NOTE: ALT. PRECAST BASE- PROVIDE SHOP DWGS
2'X 2' GRATE (TYP.
LIGHT POLE BASE
NOT TO SCALE
DR (2) 1"0 n z_
BRIC ADJUSITNG COURSE HOLES
MORTAR SOD PLUGS OR TURFSTONE PAVER
(TYP-) F GRASS SEED
C.H. TRAP
12'0 HDPE PIPE
PROPOSED
600 GALLON PRECAST
H-20 CATCH BASIN
4 VIN. SUMP USE ADJUSTED
EL 6.4 NGVD29
COX5' SHOREY SOLID
BASIN H-20 OR EQUAL
O
N /
a �n
C.B. TRAP COMPACTED SOIL111111 F ;Iii TOPSOIL IN
12"0 HDPE PIPE AT PERIMETER OPENINGS
I {+1 I OPENINGS
BEDDING SAND (1")
PROPOSED
600 GALLON PRECAST 12" PROCESSED GRAVEL BASE
H-20 CATCH BASIN
MASS D.PW. M1.03.1
4' MIN. SUMP �. \�\a y `E ','\` 1 tlrr�,r 1, ,„..i. `•' r" a'`.t< ,� i' ,r 'sr 5t8
_ r
�a
0 4.
N
OUW DATER
i S
SECTIONAL PLATE\\j f,/f�/ COMPACTED
6'0X5' SHOREY SOLIDf/fes/i j ' \/\ SUBGRADE
BASIN H-20 OR EQUAL//,�`^,',�'/�/
4x4-6/6 WELDED WIRE FABRIC CONTROL JOINT NOTE: 6" REVEAL ONLY WHERE INDICATED WHERE WWF AT EXP JT THICKEN EDGE HERE FLUSH EDGE
SEALANTSEE DETAIL.
SMOOTH TROWEL ALL 6"
EDGES 6" WIDEEITCH 1% FINE BROOM FINISH
4—
v d d d Id 1
_ _
COMPACTED AGGREGATE BASES
UNDISTURBED OR COMPACTED'
SUBSOIL
CONCRETE SIDEWALK.
N.T.S.
NOTES:
1. COMPACTED AGGREGATE BASE COURSE: 2" GRADED CRUSHED STONE ON 4" GRAVEL BORROW.
2. CONCRETE FOR SIDEWALKS MDPW CEMENT CONCRETE (AIR ENTRAINED 4000 PSI 3/4" IN.,610)
i 1" TOPCOAT TYPE DPW
v\
a 2' FINDER
0
12" PROCESSED GRAVEL
r
1 d v
r \ \ ra3fKZNO1 sgf1
DAr1' LA���,
aJ-} 2 ,� o. LA
OT 111
a 4;240
DATE DANIEL A. OJALA, P.E., P.L.S.
°TURFSTONE"TM PAVER DETAIL
NOT TO SCALE
YkmA"ETAU
WEST YARMOUTH, MA
PREPARED FOR
CHARLES WHITE MANAGEMENT
off 508-362-4541
fax 508-362-9880
downcape.com (D
down cope engineering, inc.
civil engineers
land surveyors
939 Main Street (Rte 6A)
YARMOUTHPORT MA 02675
DATE: SEPTEMBER 18, 2012
REVISED: NOVEMBER 29, 2012
REVISED: DECEMBER 17, 2012 (WLL, NATIVE PLANTINGS
PER CONCOM APPROVAL)
REVISED: FEBRUARY 28, 2013 (HEALTH COMMENTS)
REVISED: MARCH 29, 2013 (PB COMMENTS)
REVISED: APRIL 8, 2014 (LOT 1)
SHEET 5 OF 5
02-256 CHS WHT 2014.DWG