83-1931 - Site & Sewage PlanGENERAL NOTES: 1. SYSTEM IS DESIGNED IN ACCORDANCE WITH 'COMMONWEALTH OF MASS., DEPT. OF ENVIRONMENTAL PROTECTION, 310 CMR 15.00; THE STATE ENVIRONMENTAL CODE, TITLE 5: STANDARD REQUIREMENTS FOR THE SITING CONSTRUCTION, INSPECTION, UPGRADE AND EXPANSION OF ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS0 AND THE TOWN OF YARMOUTH REGULATIONS. 2. NO WELLS OR WATER SUPPLIES ARE KNOWN TO EXIST WITHIN 100 FEET OF THE PROPOSED SOIL ABSORPTION SYSTEM. ALL WELLS KNOWN TO EXIST WITHIN 150 FT. OF THE SYSTEM ARE SHOWN. 3. PRIOR TO BACKFILLING COMPLETED SYSTEM, NOTIFY THE ENGINEER AND THE HEALTH DEPARTMENT FOR INSPECTION. PROVIDE 24 HOURS (MIN.) NOTICE. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. 5. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH. 6. AREA SERVED BY TOWN WATER. TECHNICAL NOTES: 1. ALL COVERS AND INSPECTION/ACCESS PORTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED (OR SHALL BE BUILT TO GRADE AS REQUIRED BY OAKSON INC.) 2. ALL TANKS SHALL BE INSTALLED ON A LEVEL, STABLE BASE (MIN.6' STONE BASE) 3. MAINTAIN A MAXIMUM OF 36NCOVER OVER ALL SYSTEM COMPONENTS. ALL COMPONENTS SHALL CONFORM TO SPECIFICATIONS CONTAINED IN 310 CMR 15.00. 4. NO GARBAGE GRINDER ALLOWED WITH THIS DESIGN. TFST ROLL' DATA DATE OF TEST HOLES: 4/19/2012 INSP. BY: ` No. No.2 D. QUINN (R&W-SOIL EVAL.) / 73 �2 8.6 A. VON HONE (HEALTH DEPT.) A LOAMY SAND 5.6 It fj FILL / 50..8 W LOAMY SAND B LOAMY SAND4.6 5.3 B LOAMY SAND 3.8 / C1 MEDIUM TO ./,5 .11Y. G: IT. 3.B AW. 0. r. FINE SAND 2.6 0 Ar 2.1 G Ar O D MEDIUM TO O MEDIUM TD C CSAND OARSE / •47 E E C2 COARSE cm DESIGN DATA: NUMBER OF BEDROOMS PROPOSED: 2 ESTIMATED DAILY EFFLUENT: 220 G.P.D. TOTAL LEACHING AREA AS PROPOSED: BOTTOM AREA: 312 S.F. LEACHING CAPACITY AS PROPOSED: (EFFLUENT LOADING RATE = 0.74 GPD/SF) BOTTOM: 312 x 0.74 = 230.8 G.P.D. TOTAL = 230 G.P.D. NOTE A DEED RESTRICTION LIMITING THIS PROPERTY TO TWO BEDROOMS IS REQUIRED. 6.14 .91 ° / 6 5.98 7_.49 X 5.82 � 8 �C OF 7.75. F� .0 ' �1%. \ 7.33 i 10 y 9 so p0 <�� F s_o\ ys BUOYANCY FORCE OF DISPLACED WATER: 6.37 8.25' x 5.42' x 1.58' x 62.4 LB/CF = 4,409 LBS. CALCULATIONS:1500-GAL. WEIGHT OF TANK: SEPTIC TANK DOWNWARD FORCE \7.54\BUOYANCY BUOYANCY FORCE OF DISPLACED WATER: x7.80 10.17' x 6.08' x 1.28' x 62.4 LB/CF = 4,939 LBS. UPWARD FORCEWEIGHT OF TANK: = 11,833 LBS. DOWNWARD FORCE WEIGHT OF SOIL (WATER 71GHT REINF. CONC.) o 10.17' x 6.08' x 1.20' x 110 LB/CF = 8.162 LBS, DOWNWARD FORCE = 15,056 LBS. NET DOWNWARD FORCE 1000 -GAL. PUMP CHAMBER AND EFFLUENT FILTER ON � 8 �C OF 7.75. F� .0 ' �1%. \ 7.33 i 10 y 9 so p0 <�� F s_o\ ys BUOYANCY FORCE OF DISPLACED WATER: 6.37 8.25' x 5.42' x 1.58' x 62.4 LB/CF = 4,409 LBS. UPWARD FORCE WEIGHT OF TANK: = 9,200 LBS. DOWNWARD FORCE WEIGHT OF SOIL rn 8.25' x 5.42' x 2.90' x 110 LB/CF = 14.264 LBS. DOWNWARD FORCE �0��\ e. QiLG = 19,055 LBS. NET DOWNWARD FORCE (WATER 71GHT REINF. CONC.) o ` BOTTOM OTTIRON ALL TEES SHALL BE TYPLCAL SY,STEff Pj?0FILE NOT TO SCALE PROPOSED FIRST FLOOR FI = 14S NO GARBAGE GRINDER ALLOWED WITH THIS DESIGN. 21 ' DA. COVER 14'f TO WITHIN 6 IN. OFFINISH GRADE 2' 2 COVER 2 'o n. N EXISTING UTILITIES MID.) \ \ i9 \\AREA 6.37 9,000 S.F..f Z"G'nED. 40 PVC \ MONOLITHIC TANK INV EL. 1500 5.52 rn <� 1 7.55 O T o GALLON CAPACITY �0��\ e. QiLG \ 15� 6.33 (WATER 71GHT REINF. CONC.) o ` BOTTOM OTTIRON ALL TEES SHALL BE JOUR - \ \,; 21 ' DA. COVER COVERO� TO W/THIN 6 IN. 70 GAADE 2' OF FINISH GRADE 'O 9L F C r�F`�y� 8.91 G: P/P£I l0 2 FLOW UNE 1 Z"G'nED. 40 PVC VKEL• MONOLITHIC TANK INV EL. 1500 7.80 7.55 GALLON CAPACITY INV EL SEPTIC TANK (WATER 71GHT REINF. CONC.) 7.50 BOTTOM OTTIRON ALL TEES SHALL BE OR SCHED.40 P.V.C. BOTT( J.22CASE PIPE. PROVIDE GAS BAFFLE 2 92 AND EFFLUENT FILTER ON OUTLET TEE. TO HYDRAULIC UNIT (SEESHYD EEr T 2� . DRIP DISP DETAILS) PROPOSED PUMP CHAMBER 1000 -GAL MONOLITHIC PUMP CHAMBER SHALL BE UTILIZED. INSTALL ON A LEVEL, STABLE BASE. (MIN. 6' STONE BASE) ANDREW P. GROVER # 1351 I G /2(,/2oIZ SITE PLAN 14x0 �0�\k eRDeoSF\� 5x25 B.E'NCHv ,VARff- TOP OF SURVEYOR'S "MAG" NAIL EL. 11.40 (NGVD 1929 DATUM) INSTALL 300 LINEAR FEET OF PERC-RITE DRIP 1_/(/L/1Y111/1V lY11i1- DISPERSAL TUBING WITH 1' ON -CENTER SPACING AT Nott to Scale ELEVATION = 9.75 (ADJ. G.W. 0 ELEV. 4.5; 5.25' SEPARATION PROVIDED, 5' MIN. REQUIRED). PROVIDE60 T�•T��•/ NIMUM COVER OVER TUBING. PROVIDE 5' MINIMUM SEPARATION TO BUILDING CELLAR WALL LOCCIS (ALLOWED BY D.E.P. RENEWAL CERTIFICATION FOR GENERAL USE PERC-RITE DRIP DISPERSAL SYSTEM (5/23/2012) SECTION Il, #3.F). PROVIDE 40 MIL POLYETHYLENE IMPERVIOUS BREAKOUT BARRIER MATERIAL (MIN. 4' WIDE) 1' OFF pp EDGE OF DRIP TUBING AS SHOWN. TOP OF BARRIER ELEV.= 9.75 BOTTOM OF BARRIER ELEV. = 5.75�e� EXCAVATE FOR 1' AROUND `r ABSORPTION SYSTEM AS REQUIRED (SEE NOTE BELOW) TO REMOVE ALL SOIL ABOVE THE (C1) MEDIUM TO FINE SAND LAYER. BACKFILL WITH QW/3 MATERIALS MEETING THE 4 BAY SPECIFICATIONS OF 310 CMR 15.255 (3) AND (6). NOTIFY ENGINEER FOR INSPECTION OF EXCAVATION PRIOR TO REFERENCE: BACK FILLING. PROVIDE ENGINEER ASSR'S. MAP 20, PARCEL 17 24-HOUR (MIN.) NOTICE FOR L.C.P. 6940-D LOT C-1 & INSPECTION. NOTE: AS PER D.E.P. RENEWAL CERTIFICATION FOR L.C.P. 6940-B LOT D GENERAL USE PERC-RITE DRIP DISPERSAL SYSTEM(5/23/2012) NGVD 1929 DATUM SECTION ll, #19. THE SYSTEM DOES \\\\ \ NOT REQUIRE A FIVE FOOT OVER DIG PROP AS INDICATED AT 310 CMR 15.255(5) GRODE \ / ZONE: R-25 p MIN. AREA = 25,000 S.F. \\v `1 `S+ MIN. FRONTAGE = 150' SETBACKS: 30' FRONT, 15' SIDE, & 20' REAR T MAX. HEIGHT = 35' \ o, MAX. MAX. BUILDING COVERAGE = 25% 'sem h5 •\` >� / \\\ FI20�S d LOT AREA = 9,000 S.F.t 20 CR \ 5� EXIST. BLDG COVERAGE = 2,020 S.F.t (22.4%) x `•� � \\ PROP. BLDG COVERAGE = 1,379 S.F.f (15.39) n EXISTING HEIGHT = 18.1' PROPOSED HEIGHT = 20.1' F Be, \\ CONVENTIONAL LEACHING SYSTEM QR05 \ AREA & RESERVE AREA (EACH y \ 2 x2'x48.5 TRENCH LL''iiL�1�D CONFIGURATION: 221 GPD) PER D.E.P. RENEWAL CERTIFICATION -8 PROPOSED CONTOUR a \ FOR GENERAL USE PERC-RITE --8-- EXISTING CONTOUR "'SFERSAL SYSTEM 6.58 \ (5/23/2012) - W- WATER SERVICE \ Ht`0 \ SECTION II, #12 -G- GAS SERVICE U- PROP. UNGERGROUND \ \ \ UTILITY SERVICE \ -OHW- OVERHEAD UTILITIES (7 �Oe \ ti 5x50 �e �G� \5x25% 6.40\'` \ POST LIGHT X6.78 \\ _ 6.07 ` SMH rn I SEWER MANHOLE ..X6.62•,6.62 � .- \ r ' ' J `� WATER METER PIT wip x 6.6 SPOT GRADES (EXIST.) 5x25 SPOT GRADES (PROP.) 5,:75 Oe \gL. �GO� $ $A oI+ 7 2'� \\\ l�0 NOTE: THE PROPERTY 0 0 : \ i+ o o f Q l A< SHOWN HEREON IS 6.42 LOCATED IN THE FLOOD ZONE Al2 EXISTING SEPTIC TANK, D -BOX, AND (ELEVATION = 12'). LEACH FIELD TO BE ABANDONED, PUMP i G 10y� DRY AND REMOVE, OR COMPLETELY FILL t 6-- WITH CLEAN SAND (TANK'S BOTTOM MUST ' - r' Dv- BE RUPTURED TO PREVENT RETAINAGE OF 8F WATER). EXISTING LEACH FIELD SHALL BE EXCAl� o FE�G� THAN 10' FROM PROPOSED DWELLING. AND REMOVED WHERE S a0 �0A >Ff REPLACE WITH CLEAN SAND. 0O / PR)POSED DWELLING & OX -S.17 E SEWAGE TREATffFjVT ANL? DISPOSAL SYSTEM Prelaared for.- JOHN DAVID OFFICER Location: 9 CLENWOOD STREET, W. YARff0VTH Ryes.'er & FPzlcom, Inc., P.E. & P.L.S. 3 6!Wiah Hill Rd. P.O. Boa V39 Scale: r = 10' So. Orleans, AfA,0986, u;n by AIC Tel.(508) 955-831, Pate - 6/,6/,201, of z Faz (508) zoo -2306 Job No. 10903 . d'' 'J 11 L d iati _LATE