HomeMy WebLinkAbout83-1932 - Septic Design002LOCUS MAP
1f
ACCESS COVERS MUST BE WITHIN
6. OF FINISH GRADE
FIRST 2' TO
BE LEVEL -7
9' MINIMUM COVER
�4' PERF PIPE
O Ym Ma s'm xs Ym YS Ym Ym03
7.75 7.3 omore<omo= o o m o o�
BAFFLE 7.47 l 7.2 4' SOL ID
3 OUTLET 3/4' - 1 I/2' DIA.
' 'p °RD -BOX DOUBLE WASHED STONE
1500 GAL
SEPTIC TANK v LEACH FIELD
6' CRUSHED STONE OR J,7 AREA HIGH
COMPACTED BASE GROUNDWATER. EL -2.5
_ OBSERVED
GROUNDWATER. £L-2.4
PROF l L E: NOT TO SCALE
3\ �
z
FA >
A 1 6.8 v
9A 1
9Z
V
Z
�6. J
\ +
Fop
CONC E
\ -7.84
0
\ - /
\ / REM0V£4WALK.
5.9 /
6
\`
\
\
UP 102/P 15A r
J
8.2
40 MY POLY
VAPOR BARRIER TBr
VENT
INVERT OUT SEPTIC TANK:
_.t _
INVERT IN DIST, BOX:
7.47
Gam' b'/q
LEACH
INVERT IN LEACH FIELD:
7.2
INVERT END LEACH FIELD:
7.0
CONSER VA T l ON NO TES:
I. THE WORK LIMIT SHOWN SHALL BE FITTED WITH A SILT
FENCE AS REQUIRED BY THE CONSERVATION COMMISSION.
THE FENCED WORK LIMIT SHALL CONSIST OF A CONTINUOUS.
STAKED, DUG -IN FABRIC SILT FENCE. THE FENCE SHALL
REMAIN IN PLACE UNTIL THE DISTURBED GROUND IS
STABILIZED COMPLETELY. PROVIDE ALTERNATE SILT FENCE
SUCH AS STAKED HAYBALES IF NEEDED AS DIRECTED BY THE
CONSERVATION COMMISSION.
2. NO CONSTRUCTION RELATED ACTIVITY SHALL OCCUR ON THE
WETLAND SIDE OF THE WORK LIMIT.
3.� ROOF DRAINS SHALL BE DIRECTED TO SUITABLY SIZED
�� DRYWELLS OR STONE TRENCH ALONG THE DRIP LINE.
4. INITIAL SOIL STABILIZATION WITHIN THE WORK LIMIT
SHALL BE ACCOMPLISHED BY APPLICATION OF MULCH AND/OR
LOAM AND SEED WEATHER PERMITTING.
ACCESS FOR DEMOLITION AND CONSTRUCTION SHALL BE VIA
THE STREET SIDE OF THE PROPERTY WITH LIMITED ACCESS
AS SHOWN AROUND THE PROPOSED DWELLING SITE.
6. ALL DEBRIS SHALL BE LADED FROM THE SITE AS IT IS
PRODUCED AND TRANSPORTED TO A SUITABLE SOLID WASTE
HANDLING FACILITY.
7. FOR DETAILED SITE RESTORATIVE LANDSCAPING, PLEASE
SEE ADDITIONAL SITE LANDSCAPING PLANS.
8. REFER TO ANY ORDER OF CONDITIONS ISSUED FOR THE
PERFORMED WORK ACTIVITY BY THE YARMOUTH CONSERVATION
COMMISSION.
4'VENT OR
CHARCOAL FILTER MIN 2' OF PfASTONE
UFILTER FABRIC
S
VARIANCES REQUIRED:
INVERT EL E VA
T I ONS
INVERT AT BUILDING:
8.2
INVERT IN SEPTIC TANK:
8.0
INVERT OUT SEPTIC TANK:
7.75
INVERT IN DIST, BOX:
7.47
INVERT OUT DIST. BOX:
7.3
INVERT IN LEACH FIELD:
7.2
INVERT END LEACH FIELD:
7.0
BOTTOM OF LEACH FIELD:
6.5
AREA HIGH GROUND WATER:
2.5
OBSERVED GROUND WATER:
2.4
BOTTOM OF TEST HOLE #I:
2.2
TITLE 5, MAXIMUM FEASIBLE COMPLIANCE
SECTION 15.211:(1) MINIMUM SETBACK DISTANCES
10' IS REOUIRED BETWEEN THE SAS AND THE PROPERTY LINE, 3',4' A 6' ARE PROVIDED.
7'. 6', A 4' VARIANCES ARE REQUESTED. 20' IS REOUIRED BETWEEN THE SAS AND THE
FOUNDATION, 12' IS PROVIDED. AN 8' VARIANCE IS REQUESTED. 10' IS REOUIRED
BETWEEN THE SAS AND THE WATER LINE. 5' IS PROVIDED. A 5' VARIANCE 1S REQUESTED.
10' IS REOUIRED BETWEEN THE SEPTIC TANK AND THE FOUNDATION. 5' IS PROVIDED.
A 5' VARIANCE IS REOUESTED. 10' IS REOUIRED BETWEEN THE SEPTIC TANK AND THE
PROPERTY LINE. 7' IS PROVIDED. A 3' VARIANCE 15 REOVESTED.
SECTION 15.212:(6) DEPTH TO GROUNDWATER
5' IS REQUIRED BETWEEN THE BOTTOM OF THE SAS AND THE MAXIMUM GROUNDWATER
ELEVATION. 4' IS PROPOSED. A I' VARIANCE IS REQUESTED.
TOWN OF YARMOUTH SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS
REGULATION 3.7: DISTANCES A LOCATION OF DISPOSAL FACILITIES
100' IS REOUIRED BETWEEN THE SAS AND A WETLAND. 62' IS PROVIDED, A 38'
VARIANCE IS REQUESTED.
`BVW 2
\ 4
EX f T M!G D CK+
S
4jr
TO BE ,410 0 + \ � +
1 r
FIELD i6.5� e DECK
.... . PI NCE \ ✓" I ;.
IU�SgL'r �C
ZE AREA
ISTORIC
.... - t + 3. 0 EDGEROFI BETWEEN
CLEAR AND THEEDGEOF
Jf i` --° P£ASTONE UNDER DECK.
\
PROPOS OO . ry
PERVIOf'1 DRIVE
\4'
OVER L CH FIELD
r ry
f SHELLF••EL' o
DRIVEWAY
S
\ \ `�^� 9. I', •. 1500 GALLON
S
\ BL -7._3 H FND _6D MA7F• _ '' 4 -{` -i '-. + ' P
EL •7.37
T
/ \ t Ia BRr� ILK zl,_N+� +
/ 6.2
6 - _ WALL
6.1
_z
�F + 5,4
p
p4/
,Op
1 s�
Fc�a
\ �cHa,vrvc
DECK UND>:R DECK
ENTIRE LOT FALLS WITHIN FLOOD ZONE AII(EL 11)
ELEVATIONS BASED ON NGVD. BENCH MARK USED-RM26
0 5 10
20
ICO' TO EDGE OF RIVER
DESIGN CRITERIA:
GENERAL NOTES:
DESIGN FLOW:
�.
+ +PEASTONWE
\ PROPOSED TWO BEDROOM . `
UNDER DECK
BEDROOM EOUALS 220 G.P.D.
+N� +
DWELLING IN SAME FOOTPRINT' ��
f
\
+
AS EXISTING DWELLING
\'
DECK
+
evw�4
TOP OFJFOUND --12.0
4.4+
SEPTIC TANK PROVIDED: 1500 GAL. MIN.
'\ ,
;
\
SOIL ABSORPTION SYSTEM REOUIRED:
+ \
k{ T'
,
\+
.f
SECOND
\ FLOOR DECK
SOIL TEXTURAL CLASS - I
\
_ Ti , y� - + •
++ 3. 5
S
\ BL -7._3 H FND _6D MA7F• _ '' 4 -{` -i '-. + ' P
EL •7.37
T
/ \ t Ia BRr� ILK zl,_N+� +
/ 6.2
6 - _ WALL
6.1
_z
�F + 5,4
p
p4/
,Op
1 s�
Fc�a
\ �cHa,vrvc
DECK UND>:R DECK
ENTIRE LOT FALLS WITHIN FLOOD ZONE AII(EL 11)
ELEVATIONS BASED ON NGVD. BENCH MARK USED-RM26
0 5 10
20
ICO' TO EDGE OF RIVER
DESIGN CRITERIA:
GENERAL NOTES:
DESIGN FLOW:
0.
2 BEDROOMS AT I!O G.P.D. PER
I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION
BEDROOM EOUALS 220 G.P.D.
OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING
FOR LOCATION OF UNDERGROUND UTILITIES.
PURPOSES ONLY.
NO GARBAGE GRINDER
LOAMY IOYR
2. VERTICAL DATUM IS NGVD. FOR BENCH MARKS
SEPTIC TANK REOUIRED:
SET, SEE SITE PLAN.
220 G.P.D. X 200x - 440 GAL.
SEPTIC TANK PROVIDED: 1500 GAL. MIN.
3. ALL CONSTRUCTION METHODS AND MATERIALS AND
DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION
MAINTENANCE OF THE SEPTIC SYSTEM SHALL
SOIL ABSORPTION SYSTEM REOUIRED:
CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL
DESIGN PERC RATE C 5 MIN/INCH
BOARD OF HEALTH REGULATIONS.
SOIL TEXTURAL CLASS - I
SAND 576
EFFLUENT LOADING RATE - 0.74 GPD/SF
4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER
220 GPD / 0.74 GPD/SF - 298 S.F. REQUIRED
AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER
EXISTING SEPTIC SYSTEM TO BE PUMPED DRY.
THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH -
PROVIDED: TRAPIZOIDAL SHAPED LEACH FIELD
STANDING H-20 WHEEL LOADS.
A-300 S.F. x 0.74 - 222 GPD
5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR
l0.
APPROVED EOUAL
SOIL TEST PIT DA TA a
ENCOUNTERED BELOW THE INVERT OF THE LEACHING
6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED
INDICATES INDICATES
PRECAST CONCRETE OR APPROVED POLYETHYLENE,
PERCOLATION = OBSERVED
BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER
TEST GROUNDWATER
TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE
AROUND AND REPLACED WITH SAND IN ACCORDANCE
TB #1OUTLET.
HORIZON TEXTURE COLOR
7•
BEFORE CONSTRUCTION CALL -DIG-SAFE•.
0.
8 2
1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT.
FILL
FOR LOCATION OF UNDERGROUND UTILITIES.
32'
5.5
LOAMY IOYR
8.
SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE
4
SAND 5/3
DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION
35' -------------------
5.3
OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE
B LOAMY 7. SYR
CONSTRUCTION INSPECTIONS.
SAND 576
42 - - - - - - - - -
4.7 9.
EXISTING SEPTIC SYSTEM TO BE PUMPED DRY.
C I MEDIUM IOYR
REMOVED AND BACKFILLED WITH SAND.
SAND 6/8
l0.
ALL UNSUITABLE MATERIAL IFILL, A A 8 HORIZONS)
ENCOUNTERED BELOW THE INVERT OF THE LEACHING
FACILITY TO BE REMOVED FOR A DISTANCE OF 5'
70
2.4
_
AROUND AND REPLACED WITH SAND IN ACCORDANCE
WITH TITLE''5.
72
2.2
I1.
NO DETERMINATION HAS BEEN MADE AS TO
DATE: 9718/2008
_,COMPLIANCE
WITH DEED RESTRICTIONS OR ZONING
TEST BY: STEPHEN HAAS
REGULATIONS. IT SHALL REMAIN THE CLIENTS
WITNESSED BY: PHIL RENAUD
RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL
PERC RATE: C 2 MIN/INCH
PERMITS. VARIANCES ETC. FOR THIS PROJECT.
12.
ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR
LOCATION ONLY AND SHALL BE DESIGNED IN
ACCORDANCE WITH STANDARD PRACTICE.
l3.
IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY
TO HAVE THE PROPOSED BUILDING FOUNDATION
DESIGNED TO ACCOUNT FOR THE EXISTING GRADE
AND SOIL CONDITIONS AT THE LOCATION OF THE
PROPOSED BUILDING.
�OE mPEv '.
q l�� y SO'•.
� 3
61261 zo / Z-'-
\�a�QQ\
v9vwc�
/ 6.0
pp / +
SEPT I C S YS TEM DES l GN
102 BREEZY POINT ROAD. MAP 34. PARCEL 226
SOUTH YARMOUTH. MA.
PREPARED FOR:
LEGEND K AR E N L U C I A N O
®CB CONCRETE BOUND 3 MASHPA ROAD. HARW i CI -4. MA 02645
-W- WATER LINE
O HYDRANT SCALE: I- I O JUNE' 27. 2012
-G- GAS LINE
-OHW- OVER HEAD WIRES EAGLE SURVEYING, INC
4F L16HT POST _
923 Routes 6A
-E- UNDERGROUND ELECTRIC LINE
-T- UNDERGROUND TELEPHONE LINE / Y a r mo u t h p o r t 508 M 3 62-8'1 3 3. 02675
/� �fI11� �� 32
- CTV- UNDERGROUND CABLEVISION LINE �� /lI\� 5 0 8 4-32-5.333
+40.4 SPOT ELEVATION
........ 40....... EXISTING CONTOUR
40 PROPOSED CONTOUR