HomeMy WebLinkAbout83-2015 - Site Plan 2-5LEGEND
-_ 99- EXISTING CONTOUR
X 99.1 EXIST. SPOT ELEV.
99 PROPOSED CONTOUR
198.41 PROPOSED SPOT EL.
THi
TEST HOLE
2Z; SLOPE OF GROUND
rQ� UTILITY POLE
'�y FIRE HYDRANT \\
NOTE: NOT ALL SYMBOLS MAY APPEAR INN\ WING
O
NOTES dJ
1. DATUM IS NAVD88
2. MUNICIPAL WATER IS AVAILABLE
3. MINIMUM PPE PITCH TO BE 1/8" PER FOOT.
4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS
TO BE AASHO H-20
5. PIPE JOINT$ TO BE MADE WATERTIGHT.
6, CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH
310 CMR 15.000 (TITLE 5.)
7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO
BE USED FOR LOT LINE STAKING OR ANY OTHER
PURPOSE.
8. PIPE FOR (SEPTIC SYSTEM TO SCH. 40-4" PVC.
9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED
WITHOUT INSPECTION BY BOARD OF HEALTH AND
PERMISSION OBTAINED FROM BOARD OF HEALTH.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING
DIGSAFE (1-888-344-7233) AND VERIFYING THE
LOCATION OF TALL UNDERGROUND & OVERHEAD UTILITIES
PRIOR TO COMMENCEMENT OF WORK.
11. ANY UNSl IITABLE MATERIAL ENCOUNTERED SHALL BE
REMOVED 5' BENEATH AND AROUND THE PROPOSED
LEACHING FACILITY.
12. EXISTING TEACHING FACILITY SHALL BE PUMPED AND
REMOVED OR (PUMPED AND FILLED WITH CLEAN SAND.
13. GUTTERS AND DOWNSPOUTS TO ROOF DRYWELLS FOR
ALL ROOF AREAS REQUIRED. CONTRACTOR TO COORDINATE
DOWNSPOUT LOCATION WITH ARCHITECT.
14. FLOOD RESISTANT FOUNDATION DESIGN WITH
CRAWLSPACE SLAB AT OR ABOVE LOWEST ADJACENT
GRADE REQUIRED, PROVIDE SMARTVENTS ON SIDE AND
FRONT ONE PER 250 SF OF ENCLOSED AREA, VENTS TO
BE WITHIN ONE FOOT OF FINISHED GRADE/CRAWLSPACE
GRADE. ALL UTILITIES SERVICING BUILDING TO BE
ELEVATED ABOVE FLOOD ZONE ELEVATION 11.
ALARM AND CONTROL PANEL
TO BE INSTALLED INSIDE
BUILDING. ALARM TO BE ON
SEPARATE CIRCUIT FROM PUMP
--
\
INV. IN 7.5'
I *THE INSTALLER SHALL VERIFY THE
LOCATIONS OF ALL UTILITIES AND ALL
BUILDING SEWER OUTLETS AND
MAP 51 I I ELEVATIONS PRIOR TO INSTALLING ANY
PARCEL 103 �� I JESSIES LN. I PORTION OF SEPTIC SYSTEM
(KA,CZOR)
TOP FO
1 I
1 1 U1 I 4'SCH40
1 � I
n ♦1 Col ATI Al O �
PROVIDE MIN. 20" DIAM. WATERTIGHT
ACCESS COVERS TO FIN. GRADE
= MINIMUM .75'1OF COVER OVI
PRECAST H-10
SYSTEM PROFILE
(NOT TO SCALE)
2" PEASTONE.OR GEOTEXTILE
FILTER FABRIC OVER STONE
NOTE- 2" MIN. WALL
RISERS (TYP.) THICKNESS REOUTA
2'0 4"0SCH40 PVC
PROP. TEE 2" DOUBLE -WASHED PI
PIPES LEVEL IST 2' OR GEOTEXTILE FABRIC
ALL SYSTEM COMPONENTS SHALL BE
MARKED WITH MAGNETIC TAPE OR
COMPARABLE MEANS FOR FUTURE LOCATION.
27 SLOPE REQUIRED OVER SYSTEM
1 100% RESERVE
I ...... 7.78' f0" z4' TEE 7.53'
1 TEE IEE
TT1 Q o 0000000
� CIS BVRE ' GAS @qFF /�F o 0000000
2.W2
'- on
10SCLL COMPy¢•<V 9.28'
14.2 o 0"
2000GAL H-20
Ip SEPT: TANK O..O...O .O ...O O.. O ..:0 O OO C
4' U. LEVEL 0 0 0 0 0 0 0 0 0 0 0 0
ACMEOR EQUAL 0000 On Don O 0'00'0 000n00n0 ono on00n 0C
3 DWELLING TUF-TITS EF -4
EFFLUENT FILTER
0
(OR EQUAL)
- W/MOLDED IN GAS
NOTE: FLOODZONE DESIGNED F)UNDATIONS BY OTHERS DEFLECTOR
6" CRUSHED STONE OR MECHANICAL
3 COMPACTION. (15.221 [21)
PROP. VENT WITH CHARCOAL FILTER -
AND BUGSCR£EN (FINAL PLACEMENT BY (� 7. SLOPE)
CONTRACTOR WITH HOMEOWNER (-!-% SLOPE)
I CONSULTATION) DWELLING FOUNDATION 80 \
1
10.0' SEPTIC TANK - 3' - PUMP -
GARAGE FOUNDATION - 53'. CHAMBER
ARAGE
OFF�EzvPP�
� �
WATERTIGHT COVER TO GRADE (H-201
PROVIDE QUICK DISCONNECT FOR PUMP/ -a-
/ \ 10-
41
0
PROPOSED 6 1
BEDROOM DWELLING 4/
.TOP OF FND. 13.0 /
" PRESSURE LINE TO PC �� / FFLR EL. 14.0
!y CRAWLSPACE EL. 9.0
ALARM ON 1215 GAL.+ SLOPE TO DRAIN BACK \
RESERVE
FLOAT SWITCH 0.25" WEEP HOLES r L
PUMP ON \ MAP 51 0 /\L
S TTINGS: CHECK VALVE
7" WORKING RANGE 6 MYERS SRM 4 \ PARCEL 105 d �v
7" SUBMERSIBLE 4/10 HP PUMP (COLEMAN)
12" SYSTEM (OR EQUAL) /
000 00000 0 0
000000 0000 0 0 0 0000
PUMPNQTCHAMBER
TO SCALE)
WATERPROOF/WATERTIGHT
NOTE: 5.3' LIQUID LEVEL
off 508-362-4541
f" 508-362-9880
downcape.com
down cape engineering, inc"
civil engineers
land surveyors
939 Main Street ( Rte 6A)
YARMOUTHPORT MA 02675
DCE #(115-013
EXISTING RIVERFRONT DISTURBANCE (PER BSC PUN
PROP MITIGATION AREA: 40001 SF Ot SF
MAP 51
PARCEL p/o 102
F 14" OAK
"9 11, '�42' OF 4" PVC SET AT .005 SLOPE -1
ON 6" DOUBLE WASHED 3/4"- 1 1/2" STONE
H-20 D'80X
WATER TEST D'BOX FOR LEVELNESS
H-20
75'- D' BOX
(-L-% SLOPE)
- 13'
ADJUSTED G -W ELEV. 3.3'
LEAC-IING
FACILITY
SYSTEM DESIGN:
5'
GARBAGE DISPOSER IS NOT ALLOWED
DESIGN FLOW: 8 BEDROOMS 0 110 GPD = 880 GPD
USE A 880 GPD DESIGN FLOW
SEPTIC TANK: 880 GPD (2) = 1760 (FIRST COMPARTMENT)
880 GPD (1) = 880 (SECOND COMPARTMENT)
1760 + 880 = 2640 GAL. REQUIRED
USE A 3000 GAL. DUAL COMPARTMENT SEPTIC TANK
LEACHING:
SIDES: N/A
BOTTOM 42 x 30 (.74) = 932 GPD
TOTAL: 1260 S.F. 932 GPD
USE 42' x 30' LEACH FIELD OF 4" PERF. SCH. 40 PVC
IN DOUBLE WASHED STONE
, MA
DATE BOARD OF HEALTH
y 10 v j
t�x'
;�.,,
ROI E
b W
ltQ?�
JIF
\ 40
19�01 00 40
xe
�� /! em
TOTALS � �3 " W� � . W \ � hON
10,6301 SF �°
6.0201 SF
16,650-± SF
% \
3912 OFj PERV. AREA
,,S/ EXISTING Abp
64361, F DWELLING ,
' " ` " ' �(P
26041 SF Y CG /
40001 SF o �� . " / �G
17,028 SF PROPOSED �/�5����/��
i
BENCHMARK.
TOP11OF CEMENT BOUND
ELEV 85 NAVD88
r
DATE DANIEL A. OJALA, P.E., P.L.S.
GRADE
100'
212
LAWN AREAS
74301 SF
32001 SF
MULCH AREAS
6001 SF
54201 SF
TOTALS:
DISTURBANCE.
ZONING: RS -40
PROPOSED R/VERRONT
PROP. HOUSE/DECK
0 SF
3618 SF
PATIO & SPA
0 SF
208, SF
WALKWAY
0 SF
86 5F
TOTALS:
.
3912 SF
LAWN AREAS
4470 1 SF
19661 SF
MULCH AREAS
600 1 SF
20041 SF
PROP MITIGATION AREA: 40001 SF Ot SF
MAP 51
PARCEL p/o 102
F 14" OAK
"9 11, '�42' OF 4" PVC SET AT .005 SLOPE -1
ON 6" DOUBLE WASHED 3/4"- 1 1/2" STONE
H-20 D'80X
WATER TEST D'BOX FOR LEVELNESS
H-20
75'- D' BOX
(-L-% SLOPE)
- 13'
ADJUSTED G -W ELEV. 3.3'
LEAC-IING
FACILITY
SYSTEM DESIGN:
5'
GARBAGE DISPOSER IS NOT ALLOWED
DESIGN FLOW: 8 BEDROOMS 0 110 GPD = 880 GPD
USE A 880 GPD DESIGN FLOW
SEPTIC TANK: 880 GPD (2) = 1760 (FIRST COMPARTMENT)
880 GPD (1) = 880 (SECOND COMPARTMENT)
1760 + 880 = 2640 GAL. REQUIRED
USE A 3000 GAL. DUAL COMPARTMENT SEPTIC TANK
LEACHING:
SIDES: N/A
BOTTOM 42 x 30 (.74) = 932 GPD
TOTAL: 1260 S.F. 932 GPD
USE 42' x 30' LEACH FIELD OF 4" PERF. SCH. 40 PVC
IN DOUBLE WASHED STONE
, MA
DATE BOARD OF HEALTH
y 10 v j
t�x'
;�.,,
ROI E
b W
ltQ?�
JIF
\ 40
19�01 00 40
xe
�� /! em
TOTALS � �3 " W� � . W \ � hON
10,6301 SF �°
6.0201 SF
16,650-± SF
% \
3912 OFj PERV. AREA
,,S/ EXISTING Abp
64361, F DWELLING ,
' " ` " ' �(P
26041 SF Y CG /
40001 SF o �� . " / �G
17,028 SF PROPOSED �/�5����/��
i
BENCHMARK.
TOP11OF CEMENT BOUND
ELEV 85 NAVD88
r
DATE DANIEL A. OJALA, P.E., P.L.S.
GRADE
LOCUS MAP
NOT TO SCALE
4
ASSESSORS MAP 51 PARCEL p/o 102
LOCUS IS WITHIN FEMA
FLOOD ZONE
AE EL 11 AND ZONE X
0
ON COMMUNITY PANEL
#25001CO587J
DATED JULY 16, 2014
LS
ZONING: RS -40
LS
SETBACKS: 30 FRONT
/20 SIDE /20 REAR
REFERENCES:
PL BK 649 PAGE 71
7"
on o
.
Old o 5
C,� hose
LS
�
cGe A
J
4
�
30'
1OYR 5/6
9.3� 36"
1OYR 5/6
9.0'
e
rn
�
Morn.
o
0 �
i ow i
0ou
�
o
�
N
�
rn
Q
Nantucket
Sound
LOCUS MAP
NOT TO SCALE
4
ASSESSORS MAP 51 PARCEL p/o 102
LOCUS IS WITHIN FEMA
FLOOD ZONE
AE EL 11 AND ZONE X
0.2% AS SHOWN
ON COMMUNITY PANEL
#25001CO587J
DATED JULY 16, 2014
LS
ZONING: RS -40
LS
SETBACKS: 30 FRONT
/20 SIDE /20 REAR
REFERENCES:
PL BK 649 PAGE 71
TEST HOLE LOGS
ENGINEER: DAVID MASON
WITNESS: AMY VON HONE, RS (YARMOUTH)
DATE: 1/16/13
PERC. RATE _ < 2 MIN/INCH
CLASS I SOILS
0"
4
ELEV.
11.8' p"
ELEV.
12.0'
A
A
LS
LS
1OYR 2/2
1OYR 2/2
7"
7"
B
B
LS
LS
30'
1OYR 5/6
9.3� 36"
1OYR 5/6
9.0'
C C
PERC
FS FS
2.5Y 6/2 2.5Y 6/2
123" 1 1.6' 131
NO GROUNDWATER ENCOUNTERED GROUNDWATER ENCOUNTERED
0 127" EL. 1.4'
GROUNDWATER ADJUSTMENT DATA;
WELL: MIW 29
ZONE: A
ADJUSTMENT: 1.9' (JANUARY)
SITE PLAN
OF
#4 JESSIES LANE
SOUTH YARMOUTH, MA
PREPARED FOR
William & Mary Lou Jackson
DATE: FEBRUARY 5, 2015
Scele:1"= 20'
0 10 20 30 40 50 FELT
15-013 JACKSON.DWG