HomeMy WebLinkAbout83-2018 - Site PlanLEGEND - 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 150' PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 SIDE SETBACK 0 TEST HOLE 2% SLOPE OF GROUND MAX. UTILITY POLE Y FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 14-329 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. H-10 SEPTIC TANK - LEACHING: 440 GPD / (.74) = 595 SF REQUIRED CRAWL SLAB 9.5'f 77TTY 15' X 40' = 600 SF OK 600 SF X .74 = 444 GPD OK USE A 15' X 40' PIPE AND STONE LEACHING FIELD APPROVED , MA DATE BOARD OF HEALTH BENCHMARK: MAG NAIL \ELEVATION =8.65 NAVD8-78;�� PROVIDE MIN. 20" DIAM. WATERTIGHT SYSTEM PROFILE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) `5- MINIMUM .75' OF COVER OVER PRECAST 5 1] 2" PEASTONE OR GEOTEXTIL1.8' FILTER FABRIC OVER STONES ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 2% SLOPE REQUIRED OVER SYSTEM 10.1' PRECAST H-10 NOTE: 2" MIN. WALL PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE RISERS (TVP.) THICKNESS REQUIRED 2'ra rV4"6SCH40 PVC 2" DOUBLE -WASHED PEAST IPES LEVEL 1ST 2' ON 4"OSCH80 PVC f OR GEOTEXTILE FABRIC *10.23 9.28' 10" 1500 GAL H-10 EE 9.85' TEE SEPTIC TANK TEE 9.6' °000°oo°000°o°o°o°o°o°0°o°0°yoop0000 0 0 0 o°a°000°o o°o°o^o^o^o 0 osop000s000°o°00000000000°0°000°0°0 4' UQ. LEVEL 5.79' ACME OR EQUAL GAS BAFFLE °q°,°,°,°,opo°o° °o°°o°°o°°o°°o°°o°°o°o o°o°o°o°o°o°°o°o°o° 8.99' 8.82' 4" PVC SET AT .005'/' SLOPE J°oi o° . • _ - .r: - ON 6" DOUBLE WASHED 3/4" - 1 1/2" STONE .0000000000000a0000000°00000p00000a0000000000� "o°00000,°,oo_,,�°°,o°,0000°00000.o,°,o,°,o,°,o�o,°,o,°,o°000° WATER TEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [23) (-L-% SLOPE) (--Ly % SLOPE) (-L-% SLOPE) FOUNDATION- 19' - SEPTIC TANK 61 D' BOX 5' LEACHING 4"OSCH80 PVC FACILITY 0 5' USE OBS. G -W ELEV. AT 3.1' (NOTE: TIDALLY INFLUENCED) ZONING SUMMARY ZONING DISTRICT: R25 DISTRICT NOTES 1. DATUM IS NAVD88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 TITLE 5. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. POOL FENCE SHALL HAVE SELF-CLOSING SELF -LATCHING GATES, SIZE AND MATERIALS TO MEET LOCAL AND STATE BUILDING CODE, ALL DWELLING DOORS OPENING TO POOL SHALL BE ALARMED TO CODE. 14. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS. 15. PATIO -&-ROOF-RttNOFF"TO-SE-DIRECTED­TO.DRYWELLS AS SHOWN. MIN. LOT SIZE 25,000 S.F. MIN. FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BUILDING HEIGHT 35' MAX. BUILDING COVERAGE 25% SITE IS NOT LOCATED WITHIN APD OWNER OF RECORD FRANCIS POLI 404 PINE CREEK AVENUE FAIRFIELD, CT 06824 REFERENCES DEED BOOK 26479 PAGE 52 PLAN BOOK 56 PAGE 9 T"MONITORING WELL READING TABLE DATE GROUNDWATER ELEVATION TIDE 2/3/15 2.32' LOW 2/5/15 2.62' HIGH 2/6/15 2.62' HIGH 3/9/15 2.52 HIGH YarlrlOurth ConS_Fvali� e C t-_ F LL7-1 11 j. B i11 c. S�� � 0sp-A cla"1• /ON- a-- a DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 17 PARCEL 68 LOCUS IS WITHIN FEMA FLOOD ZONE AE EL. 12, AE EL. 11 (HOUSE AREA) & VE EL. 13 AS SHOWN ON PANEL 25001CO588J EFF, 7/16/14 TEST HOLE LOGS ENGINEER: DANIEL WITNESS: AMY VON DATE: 12/17/14 E. GONSALVES, HONE, RS SE #13587 p�. 2 MIN/INCH �i CLASS I SOILS ELEV. s� ELEV. p" 9.4' p" 9.3' A A LS °4 ° h LOCl/ Lewis 10YR Lewis Bay 18" Pond B Rodeo B LS overs Nantucket 1OYR 5/6 33' 6.8� Sound 1OYR 5/6 6.4' LOCUS MAP NOT TO SCALE ASSESSORS MAP 17 PARCEL 68 LOCUS IS WITHIN FEMA FLOOD ZONE AE EL. 12, AE EL. 11 (HOUSE AREA) & VE EL. 13 AS SHOWN ON PANEL 25001CO588J EFF, 7/16/14 TEST HOLE LOGS ENGINEER: DANIEL WITNESS: AMY VON DATE: 12/17/14 E. GONSALVES, HONE, RS SE #13587 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. ELEV. p" 9.4' p" 9.3' A A LS LS 1OYR 2/2 10YR _ 16" 18" _2/2 B B LS LS 1OYR 5/6 33' 6.8� 39" 1OYR 5/6 6.4' C C PERC M/CS M/CS 77„ OBS. WATER 3.0' 75" OBS. WATER 3.1' 10YR 6/8 10YR 6/8 108" 0.5' 120" -0.5' OF 57 LEWIS BAY ROAD WEST YARMOUTH, MA PREPARED FOR FRANCIS POLI DATE: MARCH 18, 2015 Scale: 1 "= 20' 0 10 20 30 40 50 FEE- I off 508-362-4541 fax 508-362-9880 downcape.com down cope engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 14-329 POLLDWG