Loading...
HomeMy WebLinkAbout83-2019 - Sewage DisposalLOCUS MAP SCALE: 1 " = 500' wk4 SCHEDULE OF ELEVATIONS TOP OF FOUNDATION, TOP OF CONCRETE 13.60 CRAWL SPACE TOP OF SLAB 9.60 INVERT OF PIPE AT FOUNDATION 11.22 INVERT AT SEPTIC TANK INLET 10.97 INVERT AT SEPTIC TANK OUTLET 10.72 INVERT AT DISTRIBUTION BOX INLET 10.56 INVERT AT DISTRIBUTION BOX OUTLET 10.39 INVERT AT CHAMBER INLET 10.17 ELEVATION OF TRENCH BOTTOM 9.00 FINISHED GRADE OVER LEACHING AREA (F.G.)- 11.8 GROUND WATER ELEVATION 3.80 BREAKOUT ELEVATION 10.71 NOTES: 1.) SEE SOIL TEST LOGS AND PLAN FOR LEACHING FIELD REQUIRED EXCAVATION DEPTH AND LIMITS. 1:37 2. SITE IS VIITHiN 100 YEAR FLOOD PLAIN AE -11 ZONE BUT IS NOT WITHIN A NITROGEN SENSITIVE AREA. NOTE: THE LOT IS GRANDFATHER. THE LOT WAS CREATED IN 1956. FILM Ulf91/1 PI�R� �A YA'S15 vo szg � 1� ar yp691BSo roar / AP zls, wr 301 4 / / ar cmntm GWAU rn M EDIT A=x PK a six tr� T1s / rmifat s.>r BOUND \ SOUTH WEST DRI7E (rum ROAD) BEN"ARK .. TOP OF CO"Q*iM BOUND 10-39NA CONVENTIONAL SYSTEM LAYOUT CULTEC CHAMBER APPROVAL IN ACCORDANCE WITH THE MODIFIED CERTIFICATION FOR GENERAL USE FOR CULTEC CHAMBERS DATED FEBRUARY 22, 2010 PURSUANT TO TITLE 5, THE FOLLOWING CALCULATIONS ADDRESS SECTION IV "CONDITIONS APPLICABLE TO THE SYSTEM OWNER - IN WHICH A SYSTEM FOR NEW CONSTRUCTION SHALL DEMONSTRATE THAT A CONVENTIONAL ABSORPTION SYSTEM USING AGGREGATE CAN BE INSTALLED ON THE SITE. DESIGN DATA: DESIGN FLOW: 5 BEDROOM SINGLE FAMILY DVIELLNG NUMBER OF BEDROOMS X 110 GAL/BR/DAY = DESIGN FLOW FIVE (5) BEDROOMS X 110 GAL/BR/DAY = 550 GAL/DAY (GPD) LEACHING FACILITY (CONVENTIONAL TRENCIi PIPE do STONE): _ < RESEARCH BY: JWN SOIL TEXTURAL CLASS (310 CMR 15.243}: CLASS I (SANDS. LOAMY SANDS) DESIGN PERCOLATION RATE <2 MIN./IN. FIELD SURVEY: KGM/JWN LONG TERM ACCEPTANCE RATE (310 CMR 15.242): 0.74 GPD/SQ. FT. DESIGN FLOW (GPD) / LTAR (GPD/SQ. FT.) = MIN. LEAMNG AREA (SO. FT.) COMPUTED BY. JWN 550 GPD / 0.74 GPD/SQ. FL = 743 SO. FT. REQUIRED. DRAFTED BY: ORD/BPG SYSTEM AREA PROVIDED (SO. FT.) _ / OF TRENCHES X LENGTH OF TRENCH X [(2 X EFFECTIVE DEPTH) + WIDTH] = 2 X 54 X [(2 X 2) + 31 = 756 S.F. DESIGNED BY. BPG PROVIDED' 743 S.F. REQUIRED' EXCAVATION AREA REQUIRED = 6410NG BY 25' WDE WTH 5' OVERDIG CHECKED BY: BJW DATE REVISION HIGH GROUND -WATER LEVEL COMPUTATION FOR 11 SOUTH WEST DRIVE 2/12/15 ADJUST ELEVATION OF SDS STEP 2 USING WATER -LEVEL RANGE ZONE 3/17/15 ADD DRIP EDGE TEST NO.: ELEV.= SITE AND DETERMINE: 4/15/15 C NSERVATION COMMISSION COMMENTS TIME ® WATER -LEVEL RANGE ZONE STEP 3 24' MARIM0 Ml1H WALY REMOVABE INTERN WATER RESOURCES CONDITIONS TIME DETERMINE CURRENT DEPTH TO COVERS OF DURABLE MATERIAL MIN. F.G.=125 2,1 UIBARON FOUNDARY USING TABLE OF WATER -LEVEL ADJUSTMENTS �IMPERIFABIE BDBN 6' OF FIIL9! GRADE 1:37 TO WATER LEVEL FOR INDEX WELL (STEP 3), AND WATER -LEVEL ZONE (STEP 2B) L W44 FRAME AND COVER CIEAlIOUT ESTIMATE DEPTH TO HIGH WATER 12' BY SUBTRACTING THE WATER LEVEL ADJUSTMENT (STEP 4) FROM MEASURED DEPTH TO WATER 12" LEVEL AT SITE (STEP 1) r� AT GRADE OR APPROVE)) EQUAL 12" 11" 11" 4' SCN 40 PVC 11" 11" 10' 10" 10" PROPOSED DMBllNG INV.=10.97 9" 1:39 9" INV.=10.72 9" 9" 8" 4 SOL 40 PW 8" 8" 8" 7' 7" APT 7" FILTER 7" 4' SOL 40 PVC MID Ir 6" 1:41 6" 10 IEE DIET LEYEL 6" 000 RATE <2 MPI RATE: RATE: BUiDONG SEIIER 4' SM 40 PVC OR CAST RON 11111111 LEAD AND GM JOINTS tat Know what's below. Call before you dig. AP 25, LOT 299 AP 25,,LOT 302 / 15 IRON ROD AREA=11, 8-S:F'-^ (FOUND) ! 1 10- yr / r Z i 7Z' 9 ORO � X11.4 NZ FENCE T� S90E�p110p=136 / AP 25, LOT 303 � AND SLT S00( AP 25, LOT 301 a / 4d' Z DTCVE ' PROPOSED vmlc0 (I'ERVIOIIS PAVERS) 1,500 GALIENN �, • ti , SEPTIC TAN( O tit / PROPOSED DSTRI131 H DO)( /?r 17x i 3 PROPOSED URM POLE Tx X14-1 11011 v� PRa 2W Ulm I I N EUy. 1Q4 I 3 PROPOSED PROPOSED 12 / CONS1RUCilON ENTRANCE OBSNA11014 PORT (IVP. OF 2) G / PROIPOSOD 1'10 21 COARSE AGGEGATE 1x7 f/' WATER SOW CONCRETE BOUND 10x5 (FOUND TYPICAL) 117.53 _ 0 __1E)__ 1--' -w °,��' SOUTH WEST DRIVE _ _ _ _ _ _ (GRAVEL ROAD) -9 BENCHMARK TOP OF CONCRETE BOUND EL 10.39 NAVE) 1988 SITE PLAN 20 SCALE: 1 = 20' twl ASSESSORS MAP 25 LOT 302 ZONING REFERENCE R-25 BUILDING SETBACK - FRONT YARD = 30' SIDE YARD = 15 ' REAR YARD = 20' (CURRENT ZONING) PROFILE OF SYSTEM POT mXJ uIIIMUM OF it COVER M9INL1 OF 3V CM OBSTRVAIION PIPE MANHOLE AND ODWR TO I OVER SYSTEM TO (1 PER FINISH GRADE C FROM FINISH GRADE i MAGNETIC TAPING SEE CR61 UC110N NOTE 7 ON SHEET 2 3' IV SOH 40 PVC M Ir CRUM STONE TIGHT JOINTs DISTRIBUTION BOX (NOT TO SG11E) GRASS SURFACE - 2Z M=M SLOPE IC TAPING JAMES W. NIEVA 39399 GRAPHIC SCALE ( IN FEET ) 1 INCH = 20 FEET FILTER FABRIC AT g4ETSTB 2 LOCAnsFIRST 0AIN. MM,77MTT LEACHING TRENCHES (NOT 70 SW) TRENCH CONFIGURATION 2 TRENCHES 44.3' LONG SPACED 12' O.C. CONTAINING 7 CULTEC 180 HD CHAMBERS EACH TRENCH �H INSPECTIONS REQUIRED OF THE DESIGN ENGINEER PLEASE NOTIFY DUNN^-McKENZIE, INC. (800-540-9720) AT LEAST 48 HOURS IN ADVANCE 1. SEPTIC TANK EXCAVATION WITH STONE PRIOR TO SEPTIC TANK PLACEMENT. 2. LEACHING FIELD EXCAVATION PRIOR TO BACKFILLING WITH "SEWER GRAVEL". 3. "SEWER GRAVEL" BACKFILL - MUST PASS SIEVE TEST (SEE NOTE #1 ON SHEET #2 UNDER "SYSTEM IN FILL"). 4. ALL PIPING AND CHAMBER ELEVATIONS PRIOR TO BACKFILL. 5. FILTER, FABRIC AND FINAL GRADING OVER ENTIRE SYSTEM. * EXCAVATION NOTE THE ENGINEER MAY ORDER THE REMOVAL OF ADDITIONAL UNSUITABLE SOIL THAT MAY BE ENCOUNTERED UPON INSPECTION OF OPEN EXCAVATION. DATUM NOTE : ELEVATIONS REFER TO THE NATIONAL GEODETIC VERTICAL DATUM - 1988 BENCHMARK NOTE: BENCHMARK SHALL BE SET WITHIN 50 FT. OF LEACHING SYSTEM PRIOR TO ANY CONSTRUCTION. REMOVE THESE SOIL HORIZONS SEE "LEACHING FIELD" NOTE 6 ON SHEET 2 SOIL TEST RESULTS TEST HOLE 14-1 11-14-14 GROUND ELEV.= 10.4 TEST HOLE: 14-2 DATE: 11-14-14 GROUND ELEV. 10.3 DEPTH HORIZON SOIL TYPE SOIL COLOR ELEVV, DEPTH HORIZON SOIL TYP SOIL COLOR ELEV. 1�10771 -2' 0 /SANDY LOAM/ / /10.2 .0-2"� 0� / SANDY LOAM /� ,10.1 2-6" Ai SANDY LOAM 7YR 7/8 / ',9.9 2-6"/// ! A %SANDY LOAM ,7YR 7/8 9.8/ 6-12' E SAND 5YR 8/1 9.4 6-17' E SAND 5YR 8/1 8.9 12-48' B SAND 7YR 5/8 6.4_ 17-54" B SAND 7YR 5/8 5.8 48-120' C SAND IOYR 6/6 0.4 54-120" C SAND NOIR 6/6 0.3 GROUNDWATER WEEPING 0 110' 1.23 GROUNDWATER WEEPING 0 10C 1.30 GROUNDWATER ELEV. (2.50 FRIMPTER ADJUSTMENT) 3.73 GROUNDWATER ELEV. (2.5' FRIMPTER ADJUSTMENT) 3.80 CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 TEST HOLE DATE GROUND ELEV.= TEST HOLE DATE GROUND ELEV. Q P( yOH RIZON ML -LY -PE SOIL COLO I RDE DMON RIZON SOIL TYPE SOIL COLOR I ELEV. SOIL EVALUATOR: JAMES W. NIEVA, PLS, C.S.E HIGH GROUND -WATER LEVEL COMPUTATION FOR 11 SOUTH WEST DRIVE STEP 1 MEASURE. DEPTH TO WATER TABLE TO NEAREST 1/10 FT. DATE 11/14/14 09-70 STEP 2 USING WATER -LEVEL RANGE ZONE TEST NO.: 14-2 ELEV. 10.3 AND INDEX WALL MAP LOCATION TEST NO.: ELEV.= SITE AND DETERMINE: ® APPROPRIATE INDEX WELL W2 TIME ® WATER -LEVEL RANGE ZONE STEP 3 USING MONTHLY REPORT "CURRENT INTERN WATER RESOURCES CONDITIONS TIME DETERMINE CURRENT DEPTH TO DATUM WATER LEVEL FOR INDEX WELL 11/14 9 8 STEP 4 USING TABLE OF WATER -LEVEL ADJUSTMENTS SOAK FOR INDEX WELL (STEP 2A), CURRENT DEPTH 1:37 TO WATER LEVEL FOR INDEX WELL (STEP 3), AND WATER -LEVEL ZONE (STEP 2B) DETERMINE WATER -LEVEL ADJUSTMENT2.5 STEP 5 ESTIMATE DEPTH TO HIGH WATER 12' BY SUBTRACTING THE WATER LEVEL ADJUSTMENT (STEP 4) FROM MEASURED DEPTH TO WATER 12" LEVEL AT SITE (STEP 1) r� 12" AP 25, LOT 299 AP 25,,LOT 302 / 15 IRON ROD AREA=11, 8-S:F'-^ (FOUND) ! 1 10- yr / r Z i 7Z' 9 ORO � X11.4 NZ FENCE T� S90E�p110p=136 / AP 25, LOT 303 � AND SLT S00( AP 25, LOT 301 a / 4d' Z DTCVE ' PROPOSED vmlc0 (I'ERVIOIIS PAVERS) 1,500 GALIENN �, • ti , SEPTIC TAN( O tit / PROPOSED DSTRI131 H DO)( /?r 17x i 3 PROPOSED URM POLE Tx X14-1 11011 v� PRa 2W Ulm I I N EUy. 1Q4 I 3 PROPOSED PROPOSED 12 / CONS1RUCilON ENTRANCE OBSNA11014 PORT (IVP. OF 2) G / PROIPOSOD 1'10 21 COARSE AGGEGATE 1x7 f/' WATER SOW CONCRETE BOUND 10x5 (FOUND TYPICAL) 117.53 _ 0 __1E)__ 1--' -w °,��' SOUTH WEST DRIVE _ _ _ _ _ _ (GRAVEL ROAD) -9 BENCHMARK TOP OF CONCRETE BOUND EL 10.39 NAVE) 1988 SITE PLAN 20 SCALE: 1 = 20' twl ASSESSORS MAP 25 LOT 302 ZONING REFERENCE R-25 BUILDING SETBACK - FRONT YARD = 30' SIDE YARD = 15 ' REAR YARD = 20' (CURRENT ZONING) PROFILE OF SYSTEM POT mXJ uIIIMUM OF it COVER M9INL1 OF 3V CM OBSTRVAIION PIPE MANHOLE AND ODWR TO I OVER SYSTEM TO (1 PER FINISH GRADE C FROM FINISH GRADE i MAGNETIC TAPING SEE CR61 UC110N NOTE 7 ON SHEET 2 3' IV SOH 40 PVC M Ir CRUM STONE TIGHT JOINTs DISTRIBUTION BOX (NOT TO SG11E) GRASS SURFACE - 2Z M=M SLOPE IC TAPING JAMES W. NIEVA 39399 GRAPHIC SCALE ( IN FEET ) 1 INCH = 20 FEET FILTER FABRIC AT g4ETSTB 2 LOCAnsFIRST 0AIN. MM,77MTT LEACHING TRENCHES (NOT 70 SW) TRENCH CONFIGURATION 2 TRENCHES 44.3' LONG SPACED 12' O.C. CONTAINING 7 CULTEC 180 HD CHAMBERS EACH TRENCH �H INSPECTIONS REQUIRED OF THE DESIGN ENGINEER PLEASE NOTIFY DUNN^-McKENZIE, INC. (800-540-9720) AT LEAST 48 HOURS IN ADVANCE 1. SEPTIC TANK EXCAVATION WITH STONE PRIOR TO SEPTIC TANK PLACEMENT. 2. LEACHING FIELD EXCAVATION PRIOR TO BACKFILLING WITH "SEWER GRAVEL". 3. "SEWER GRAVEL" BACKFILL - MUST PASS SIEVE TEST (SEE NOTE #1 ON SHEET #2 UNDER "SYSTEM IN FILL"). 4. ALL PIPING AND CHAMBER ELEVATIONS PRIOR TO BACKFILL. 5. FILTER, FABRIC AND FINAL GRADING OVER ENTIRE SYSTEM. * EXCAVATION NOTE THE ENGINEER MAY ORDER THE REMOVAL OF ADDITIONAL UNSUITABLE SOIL THAT MAY BE ENCOUNTERED UPON INSPECTION OF OPEN EXCAVATION. DATUM NOTE : ELEVATIONS REFER TO THE NATIONAL GEODETIC VERTICAL DATUM - 1988 BENCHMARK NOTE: BENCHMARK SHALL BE SET WITHIN 50 FT. OF LEACHING SYSTEM PRIOR TO ANY CONSTRUCTION. REMOVE THESE SOIL HORIZONS SEE "LEACHING FIELD" NOTE 6 ON SHEET 2 SOIL TEST RESULTS TEST HOLE 14-1 11-14-14 GROUND ELEV.= 10.4 TEST HOLE: 14-2 DATE: 11-14-14 GROUND ELEV. 10.3 DEPTH HORIZON SOIL TYPE SOIL COLOR ELEVV, DEPTH HORIZON SOIL TYP SOIL COLOR ELEV. 1�10771 -2' 0 /SANDY LOAM/ / /10.2 .0-2"� 0� / SANDY LOAM /� ,10.1 2-6" Ai SANDY LOAM 7YR 7/8 / ',9.9 2-6"/// ! A %SANDY LOAM ,7YR 7/8 9.8/ 6-12' E SAND 5YR 8/1 9.4 6-17' E SAND 5YR 8/1 8.9 12-48' B SAND 7YR 5/8 6.4_ 17-54" B SAND 7YR 5/8 5.8 48-120' C SAND IOYR 6/6 0.4 54-120" C SAND NOIR 6/6 0.3 GROUNDWATER WEEPING 0 110' 1.23 GROUNDWATER WEEPING 0 10C 1.30 GROUNDWATER ELEV. (2.50 FRIMPTER ADJUSTMENT) 3.73 GROUNDWATER ELEV. (2.5' FRIMPTER ADJUSTMENT) 3.80 CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 TEST HOLE DATE GROUND ELEV.= TEST HOLE DATE GROUND ELEV. Q P( yOH RIZON ML -LY -PE SOIL COLO I RDE DMON RIZON SOIL TYPE SOIL COLOR I ELEV. l-- 3V -4 206 DEDHAM STREET, Rt.1A at Rt.115 NORFOLK, MASSACHUSETTS 02056 (508) 384-3990 - FAX (508) 384-3905 TRENCH CROSS SECTION email: staff@dunnmckenzie.com (NOT TOSr&[) DATE: JANUARY 16, 2015 SHEET 1 OF 21 JOB NO. 5221 SOIL EVALUATOR: JAMES W. NIEVA, PLS, C.S.E I B.O.H. AGENT: AMY L vonHONE, R.S., C.H.O. PERCOLATION TESTS TEST NO.: 14-2 ELEV. 10.3 TEST NO.: ELEV.= TEST NO.: ELEV.= TEST NO: ELEV. DATUM TIME INTERVAL DATUM TIME INTERN DATUM TIME INTERVAL DATUM TIME INTERVAL SOAK 1:22 - 1:37 SOAK SOAK SOAK 12' 1:37 12" 12" 12" 11" 11" 11" 11" 10' 10" 10" 10" 9" 1:39 9" 9" 9" 8" 8" 8" 8" 7' 7" 7" 7" 6" 1:41 6" 6" 6" RATE <2 MPI RATE: RATE: RATE: eO DATE 11-14-14 DATE: DATE: DATE: DEPTH: 36" DEPTH: DEPTH: DEPTH: 1 CERTIFY THAT ON JULY 1, 2010, 1 HAVE PASSED THE EXAMINATION APPROVED BY THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND THAT THE ABOVE ANALYSIS HAS BEEN PERFORMED CONSISTENT WITH THE REQUIRED TRAINING, EXPERTISE, EXPERIENCE DESCRIBED IN 310CMR 15.018(2). JAMES W. NIEVA, PLS, SOIL EVALUATOR SE#13258 TITLE 5 SEWAGE DISPOSAL SYSTEM FOR A PROPOSED 5 BEDROOM DWELLING LOCATION 10 K IN O 11 SOUTH WEST DRIVE wo YARMOUTH, MA 02601 APPLICANT RECORD OWNER: S.L. BENOIT GEORGE & JANA TARASENKO 206 DEDHAM STREET NORFOLK, MA 02056 87 PATRICKS RUN STOUGHTON, MA 02072 N 508-889-5992 Dunn " McKenzie, Inc. Tf --ITIE 5 SEMfR SAND LAND SURVEYING AND CIVIL ENGINEERING l-- 3V -4 206 DEDHAM STREET, Rt.1A at Rt.115 NORFOLK, MASSACHUSETTS 02056 (508) 384-3990 - FAX (508) 384-3905 TRENCH CROSS SECTION email: staff@dunnmckenzie.com (NOT TOSr&[) DATE: JANUARY 16, 2015 SHEET 1 OF 21 JOB NO. 5221