Loading...
HomeMy WebLinkAbout83-2020 - Site PlanTOP FOUND. 140 PVC 7.0' SYSTEM PROFILE PROVIDE WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE (OR TO GRADE IF WITHIN DRIVEWAY) 2" PEASTONE OR GEOTEXTILE L. 22.0' FILTER FABRIC OVER STONE 19.5' MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 PROP. TEE RISERS (TYP.) ym 4" OS PVC PIPES LEVEL 1ST 2' 4. ENDS to" 1a" _ . 16.75' TEE 1500 GAL H-10 TEE - - - ®®m® SEPTIC TANK 16.5' .. o 0 0 o ��®�® 4• UQ. LEVEL GAS BAFFLE o 000p00000poo oc oo®�� ACME OR EQUAL o °02020202020 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. WATERTIGHT CI COVER TO GRADE IF UNDER DRIVEWAY) 2% SLOPE REQUIRED OVER SYSTEM BLOCKS OR MORTAR ALL PRECAST RISERS COMPONENTS H-20 (7Yp,) INV'S EL_ 14.4' 4' I IDES 15.4' 14.68' 14.51' °°° ogo ogog] 12.4' °o°o°o0-0_0-0-0-0-0o0oc ° H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 0000000000000000°00000C 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.0' X 12.83' COMPACTION. (15.221 [2]) (1+_% SLOPE) FOUNDATION- 1 1 ' SEPTIC TANK TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE WITNESS: PHIL RENAUD, BOH WELL: DATE: 10/09/13 ZONE: A ADJ.: PERC. RATE _ < 2 MIN/INCH c CLASS I SOILS z� I ELEV. 4 F I ELEV. 4 p^ 15.0' 0„ 17.9' LS LS 10YR 3/2 1OYR 3/2 10" 12" B B LS LS 34" 10YR 6/6 12.2' 36" 10YR 6/6 14.9' C C PERC FS FS 2.5Y 7/6 2.5Y 7/6 108 1 OBS WATER 6.0' 120" 5.0' 120" EXIST WELL DATA: WELL: TSW 89 ZONE: A ADJ.: 1.4' NGWE #4 7.9' EDGE ( 10 % SLOPE) 18' D' BOX \ PROP 20'x 14' SHED ON POSTS 0 SOLAR PANEL ARRAY & STORAGE (TO BE ANCHORED AS REQUIRED WITHIN THE 100 YEAR FLOODZONE) EXISTING WELL (ABANDON AS PO ABLE WELL) SAS LOCATION PROP. PROPANE TANK (FINAL LOCATION AS PER OWNER) BENCHMARK: TOP CONC.I BOUND AT ELEV. 21.25' CS FND HIGH PT/ (EL. 20) I off 508-362-4541 fax 508-362-9880 downcope.com down cape engineering, h7C. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 DCE ##89-277 CB FND. .2/ (� % SLOPE) 13' \ �5 LEACHING FACILITY SALT MARSH USE ADJ. GROUNDWATER 0 ELEV. 7 TOTAL LOT AREA: 3 35 ACRES PER ASSESSORS BVW #10 #12 VE EL 16 '1 WETLAND AE EL 15 BVW#9) TEST HOLE \ \ WETLAND 0 TEST, I#10 \ DITCH j` 1 #8 =OGF #6 _ ETLAN tE5 \ \ O,V,_ HOUSE N (REMOVE) T. J 47 LIMIT LINE (RE -LOCATE) N EXIST. GARDEN O \SOLAR ♦ ` ,�, 2� ANELS --" F 4 is Lu D �_ •I, Z z EXIST. y O C4� I DEOK �_ I�'u�- 12-----\61 �+ s PROP: - - -I- -t - - DWELL. _T \ \ q TOP FNDN -L .T�-I ---- -- `--II \ PANE = 122.0' PROP.PRO CR. 0 % OR CH IRE VE ! I I Posrs I TH 1 18 I EXIST. DWELL � I C4vEL 14 \ 19 20 I 1 FND. 2° 11 � 0 0 u` e TH 2 20 ( SWAY) 20 \\ - o O ^ D1Ft 1S 19 PROP. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT 13Y ,- - - CONTRACTOR WITH HOMEOWNER CONSULTATION) i 17 PRO 78 AT ! OFF ILINER SAS IN AREA SHOWN. TOP AT EL. 15 4'S ! BOTTOM AT EL. 11.4' ! 5' REMOVAL OF UNSUITABLE SOIL REQUIRED ! 7g AROUND PORTION OF PERIMETER OF SAS I (HATCHED AREA). REPLACE WITH CLEAN MED. I l SAND. UI Ip� I ! I 12aJ I 1 y T� I I No\� � \ NoN44 QR/ ANIELA m` l �o� DANIEL OJALA 1� o A. CNIL " OJALA i No. 40980 �I.,r1� Fss ENN,.n 7LA, Rk)Fl.DATE DANIEL A. 0JP.E., P. S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 150 PARCEL 47 LOCUS IS WITHIN FEMA FLOOD ZONE X, AE EL 15 AND AE EL. 14 ON PANEL #25001CO577J DATED JULY 16, 2014 NOTES 2. MUNICIPAL WATER IS NOT AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKnLLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. WETLAND FLAGGED BY HAMLYN CONSULTING 14. DRYWELLS REQUIRED FOR ROOF RUN-OFF SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.8) 2 (.74) = 111.9 GPD BOTTOM 25 x 1-2.8 (.74) = 236.8 GPD TOTAL: 471 S.F. 348.7 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AT ENDS AND 4' AT SIDES APPROVED MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 357 HOCKANOM ROAD YARMOUTH PORT PREPARED FOR FRANCIS FARRINGTON & SUZANNE HAYDEN FEBRUARY 24, 2015 REV. 5/14/15 (HEALTH DEPT. COMMENTS) Scale:1 "= 20' I 0 10 20 30 A0 50 FEET I us °l 3 P King's e O� Way a ', o o G� a° etU�ke� o oG c ° 5 c z� n a° LOCUS MAP NOT TO SCALE ASSESSORS MAP 150 PARCEL 47 LOCUS IS WITHIN FEMA FLOOD ZONE X, AE EL 15 AND AE EL. 14 ON PANEL #25001CO577J DATED JULY 16, 2014 NOTES 2. MUNICIPAL WATER IS NOT AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKnLLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. WETLAND FLAGGED BY HAMLYN CONSULTING 14. DRYWELLS REQUIRED FOR ROOF RUN-OFF SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.8) 2 (.74) = 111.9 GPD BOTTOM 25 x 1-2.8 (.74) = 236.8 GPD TOTAL: 471 S.F. 348.7 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AT ENDS AND 4' AT SIDES APPROVED MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 357 HOCKANOM ROAD YARMOUTH PORT PREPARED FOR FRANCIS FARRINGTON & SUZANNE HAYDEN FEBRUARY 24, 2015 REV. 5/14/15 (HEALTH DEPT. COMMENTS) Scale:1 "= 20' I 0 10 20 30 A0 50 FEET I