HomeMy WebLinkAbout83-2025 - Site Plan - Septic System DetailsNOT TO SCALE NOTES: 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. 2. SEPTIC TANK SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING. 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4. TEES SHALL BE SCH. 40 PVC AND SHALL BE LOCATED WITHIN 12" OF TANK WALL AND ACCESSIBLE FROM TANK COVER. D KNCKO OUTS WITH HYDRAULIC CEMENT. 5. FILL ALL UNUSE T 4" EL 8.44 10" , 3 4' MIN. „ LIQUID 5'-8 _ 4'-7" LOCATE DEPTH , INLET TEE OUTLET TEE 6'-6" ( J ( j _ UNDER COVER W/GAS BAFFLE 4" 1 3" L r -v PLAN VIEW CRflS$—SECT30N VIEW RAISE AT LEAST ONE EXISTING COVER .To WITHIN 6" OF FINISHED GRADE THE RISER SHALL BE HOPE PIPE CONIC, COVER OBSERVATION PORT NOT TO SCALE 7" HDPE VALVE BOX—\ FINISH GRADE T 3" MAX ARC 36 CHAMBER AND DETAILS NOT TO SCALE 14" THREADED CAP { INSTALLED { LENGTH 60" — f jTO/////// ENGINEER SHALL INSPECT WHEN THE REQUIRED EXCAVATION IS COMPLETE. 2, NOjL- SHALL LOCATE AND STAKE FOOTINGS (LOOSE STONE BED) PRIOR TO INSTALLATION. 0 ENGINEER OBSERVATION PORT SHALL BE INSTALLED UTILIZING THE INSPECT 4" SCH. 40 PVC KNOCKOUT ON THE TOP OF THE 0 PERFORATED PIPE ARC 36 CHAMBER AND SHALL WHEN CLEAN FILL WITH A PERCOLATION RATE OF LESS THAN TWO T EXTEND DOWN TO THE EXISTING INCH HAS BEEN PROPERLY DEPOSITED. 5. SUBGRADE. SEE PLAN VIEW FOR O INSPECT LOCATION OF OBSERVATION PORT. H10A EXISTING SUBGRADE TYPICAL SECTION- UNREINFORCED RETAINING WALL NOT TO SCALE 40 MTI POLY LINER CAP UNIT ADHERES TO TOP UNIT i— COMMON BACKFILL W/VERSA—LOK CONCRETE ADHESIVE OR APPROVED EQUAL MOSAIC PANEL HEIGHT VERSA—LOK OR APPROVED EQUAL CONCRETE UNITS (COBBLE, ACCENT AND STANDARD UNITS) EL 4.7-8.0 GRANULAR LEVELING PAD MIN. 6" THICK 6.5" 9" SIDE PORT COUPLER SELECT FILL MEETING THE REQUIREMENTS OF 310 CMR 15.255(3) Z' VERSA—LOK OR APPROVED EQUAL STANDARD UNIT (BASE COURSE) HEIGHT SIDE VIEW INSPECTION SCHEDULE END CAP FRONT VIEW 1. ENGINEER SHALL INSPECT WHEN THE REQUIRED EXCAVATION IS COMPLETE. 2, ENGINEER SHALL LOCATE AND STAKE FOOTINGS (LOOSE STONE BED) PRIOR TO INSTALLATION. 3. ENGINEER SHALL INSPECT FOOTING LOCATION PRIOR TO INSTALLATION OF WALL 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL WITH A PERCOLATION RATE OF LESS THAN TWO T (2) MINUTES PER INCH HAS BEEN PROPERLY DEPOSITED. 5. ENGINEER SHALL INSPECT WHEN THE COMPONENTS OF THE SEPTIC SYSTEM AND THE PUMP ROTATE HOUSE MECHANISMS HAVE BEEN INSTALLED. i� BRIAN G. v'1 xj o� YERGATIAN t1" CIVIL 1'O 9 No. 462 FCISTf FSSlOq AL BRIAN G. YERGATIAN DATE PROFESSIONAL ENGINEER SEPTIC SYSTEM DESIGN 152 PAWKANNAWKUT DRQ IN SOUTH YARMOUTH MASSACHUSETTS (BARNSTABLE COUNTY) SITE PLAN FEBRUARY 3, 2014 NO. DATE DESC. T :2/11/15 PER HEALTH AGENT 2 2/13/15 BTM WALL ELEVATION 3 11/25/15 ROTATE HOUSE 4 '1/26/16 2000 GALLON SEPTIC TANK PREPARED FOR: JESSIES LANE, LLC Mr. PAUL BUTLER 25 JEROME AVE, BLOOMFIELD, CT pkbutIer2O02@yahoo.com V L4KC GROUP '349 Route 28, Unit D W. Yarmouth, Massachusetts 02673 508 778 8919 2015 BSC Group, Inc. SCALE: 1" = 10' 0 5 10 20 FEET FILE:, P:/Frj/433 00/Cs Tt/­,Dror../499SS00—SP.dag DWG.' NO: 6288-04 SHEET 2 OF 2 JOB.. NO: 4-915,85.01