HomeMy WebLinkAboutEngineered Plans - Rev. 2016LOCUS MAP WILLOW ST pad 5 TOP OF !1� GROVE ST m FOUNDATION MELVA ST EVERGREEN ST DANBURY ST EL. 6.80' LOCUS NOT TO SCALE DESIGN CALCULATIONS FLOW RATE: EXISTING 1 BEDROOM DWELLING = 110 G/P/D REQUIRED (110 G/P/D PER BEDROOM x 1 BEDROOM) MINIMUM 3 BEDROOM DESIGN REQUIRED DISTRIB NO GARBAGE GRINDER ALLOWED BOX SEPTIC TANK: 110 G/P/D x 2 = 220 G/P/D REQUIRED USE 1500 GALLON SEPTIC TANK SOIL ABSORPTION SYSTEM: PERC RATE = <2 MIN/IN — CLASS I SOIL DISTRIBTU BOTTOM: (28)(12) = 336 S.F. LINE TYP. (336)(0.74) - 248.64 G/P/D PROVIDED USE: (1) 28' LONG x 12' WIDE x 0.5' DEEP LEACH FIELD AS SHOWN IN DETAIL. DEEP HOLE DATA PERFORMED BY: JASON C. ELLIS, R.S., S.E. WITNESSED BY: AMY VON HONE, HYARMOUTH BOH TEST DATE: MARCH 31, 2016 Perm,it valid for REPA ONLY; due to State a DEPTH �• Board of Health review 0.0r 1 3.2 e.to any. future addition sewage facilities, and/or st Y Outh t] 7.,D IAPP 4.n' C MEDIUM SAND IOYRB/3 GROUNDWATER ENCOUNTERED O 84" - EL 1.10' EL. 8.0'1 PROPOSED SEPTIC TANK W/°N6- �1 COVER - OF GRADE 1'.. 7 :.. OF GRADE SECTION DETAIL - COMPONENTS NOT TO SCALE PROPOSED PUMP CHAMBER PROPOSED DISTRIBUTION BOX CCOVER- . OF GRADE + ' TO ALARM PANEL INSTALL CHECK VALVE INSTALL WEEP HOLE 'IN 6' GRADE PROPOSED SOIL ABSORPTION SYSTEM (1) 28' x 12' x 0.5' LEACH FIELD LEACH AREA TO BE PROVIDED WITH AT LEAST ONE INSPECTION PORT CONSISTING OF A PERFORATED FOUR INCH PIPE PLACED VERTICALLY DOWN INTO THE STONE TO THE NATURALLY OCCURING SOIL OR SAND FILL BELOW THE STONE. THE PIPE SHALL BE CAPPED WITH A SCREW TYPE CAP AND ACESSIBLE WITHIN 3" OF GRADE. EL. 8.0'1 EL. 6.68' y PROPOSED 1,500 GALLON EL. 6.43' U EL. 7.27' SEPTIC TANK / EL. 7.1' 0.5' PROPOSED 1000 GALLON EL. 6.43' PUMP CHAMBER EL. 7.27' z' of 1/e" TO 1/2" INSTALL GAS BAFFLE AT OUTLET EL. 7.0' DOUBLE WASHED PEASTONE INSTALL EFFLUENT FILTER 3/4" TO 1 1/2' 4.1' EL. 6.3' �. IN OUTLET TEE PUMP CHAMBER: DOUBLE WASHED STONE j USE (1) 1,000 GALLON SEPTIC TANK EL On. - 1.10' EL ADJ. - 2.20' ` p USE MYERS PUMP SRM4 4/10 HP OR EQUIVALENT GROUND WATER ELEVATION FLOAT SETTINGS: PUMP ON = 14" PUMP OFF = 11" REFERENCE WELL = MIW-29 ZONE A UTION 28 ALARM ON a 16" MARCH 2016 LEVEL = 7.37' ADJUSTMENT FACTOR = 1.1' \ STORAGE CAPACITY PROVIDED = 666 GALLONS i MINIMUM 3 BEDROOM DESIGN (330 G/P/D/) MINIMUM 4 CYCLES REQUIRED PER DAY MAXIMUVOLUMEMVOLUME PROVIDED PERRED ER 8 GALLONS E CYCLE: 82.5 GALLONS NOTES D. ION EVERGREEN 1. ALL PRECAST COMPONENTS TO BE H-10 RATED. ALL / STREET COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC WATER VARIANCE REQUESTS: 2. ELEVATION TO BE 2DATUM E S FROM USGS QUAD MAP. LEACH FIELD N SHUT—OFF 3. MUNICIPAL WATER IS AVAILABLE. SAS DETAIL C.B. t 310 CMR 15.211 4. ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000 ''•' 8 1. 4' VARIANCE FROM PROPOSED SEPTIC AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL FND. TANK TO FOUNDATION. CODES AND REGULATIONS. ��— (10' REQUIRED, 6' PROVIDED, 4' VARIANCE 5. INSTALLER/CONTRACTOR TO REVIEW & VERIFY ALL N 83"57'40" yy ` REQUESTED) ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES 8 TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL 50.00' �_ 2. 4' VARIANCE FROM PROPOSED PUMP RESPONSIBILITY. CHAMBER TO FOUNDATION. 6. INSTALLER/CONTRACTOR IS RESPONSIBLE FOR MAINTAINING OF F SEl'1 IC SYS 4 4 4 S.F.t 3 C.B. (10' REQUIRED, 6' PROVIDED, 4' VARIANCE SAFE WORK AREA, VERIFING ALL UTILITIES AND NOTIFYING 1 I.ucal septic variances. �Q FND. REQUESTED DIG SAFE PRIOR TO CONSTRUCTION. d approval iroval is required for 7. ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST I { y 3. 8' VARIANCE FROM PROPOSED LEACH BE APPROVED IN WRITING BY J.C. ELLIS DESIGN CO. AND ovxtionsialterations to Q` FIELD TO FOUNDATION. O BOARD OF HEALTH. r tures/dwelling. I (20' REQUIRED, 12' PROVIDED, 8' VARIANCE 8_ FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3' / REQUESTED) PER 310 CMR 15.000. h lkpLartnte 3 310 CMR 15.240 9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE V L.I �Z� w 8 LEACH AREA. AND IN SIZE OF REQUIRED PUMANDPREPLACED WITHED DRY AND LCLEANLED ISAND.�N SAND OR REMOVED PO ENTS TO BE PROVIDED WITH WATERTIGHT SURVEY PLAN REFERENCE: PLAN BOOK 72 PAGE 51 PLAN BOOK 146 PAGE 145 THIS PLAN IS FOR SEPTIC SYSTEM DESIGN PURPOSES ONLY. JASON C. ELLIS, R.S. 10. ALL COM N LL1 3 PC , 156 0 3 ACCESS PORTS WITHIN 6" OF FINISH GRADE. BENCHK 11. ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO Nb) EXis WELLING / � MAR0 TOP OF CONC. BOUND BE INSTALLED WATERTIGHT. 0 T.O.FDN.= 00 N EL. 8.46' M.S.L. t 12. LEACH KNOWN EXIST WITHIN 100' OF PROPOSED EL. 8.84' 0 13. PROPOSED SEPTIC TANK, PUMP CHAMBER AND DISTRIBUTION Z b PCL. 154 BOX TO BE INSTALLED ON COMPACTED STABLE BASE. 8 10.5' 10 io - PROPOSED PUMP CHAMBER TH#1 O 0 0 EXISTING 10 7' CESSPOOL (ABANDON) ' C.B. 0 U ;PATIO; ', SHE FND. ;; 50.00' PCL. 167 I N 83'57'40" W PCL. 168 11_.3' 0 PROPOSED SEPTIC TANK PROPOSED LEACH FIELD J.C. ELLIS DESIGN v o/ C.B. FND. PROPERTY OWNER AND P.O. BOX 81 CONTRACTORS TO VERIFY NORTH EASTHAM, MA 02651 ALL WATER LINES AND GAS (508)240-2220 UTILITIES ON PROPERTY. jcellisdesignOverizon.net SEPTIC SYSTEM UPGRADE PLAN SUBJECT: 5 EVERGREEN STREET YARMOUTH, MA PREPARED FOR: RAYMOND GALLUP P.O. BOX 77 EAST DENNIS, MA 02641 ASSESSOR'S SCALE: 1"=20' MAP 34 PARCEL 155 DATE: APRIL 1, 2016I SHEET 1 OF 1 SEPTEMBERREV. SEPTEMB30, 2016