Loading...
HomeMy WebLinkAboutEngineered Plans - 2016EXISTING CESSPOOLS & PIT PUMP, FILL WITH SAND & ABANDONED, OR REMOVED BENCHMARK BULKHEAD COR. EL. =103.65 o PETER T. McENTEE o CIVIL " 35109 J0�\ 11 - x \ s 103,09 \ 103,88 x 102.6 10 1, 226-pG 77 S 07'42'20" E x123.29' 101.56 vvo � 1 X__ x01,241! PROPOSED SEPTIC TANK 100.60 t / 99.00 x 21__x `\ 0 04,03 10 ,90 + 102,7E x 103.20 B ' EXISTING CONTOUR 102, 0 5 LLj -9.H.•W.-OVERHEAD WIRES LeBlanc, 7 Haywood Avenue, So. PATIO 0 0 2" SEWER 1 O 04 DATE 8/11/16 INV.SEWOER� �//IN=102.5E V. / SHEET No. 1 of 2 a, EXISTING z HOUSE(1145) m T. 0. F. =103.8E 02,8 x 102.93 103,03 102.58 GARAGE -.. - --- .ate lei-- - - -LOT 1 x 101,40 0 12,145 ±SF 70.00' 98.91 99,02I S 07'55'20" E - 9811 _�- 98166 edge of 97,90 pavement AVAI WFUT 02� .� Q�TP 98.90 •,••.oma •-. \� x 1T.53V f f f f c6 f f f ' 102.1 x10'0,: x � 101.15 ' i V CATCH BASIN 97.28 al* x 98,71 99,72 99.02 SB - -101-- EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE -W---EXISTING WATER SVC. -9.H.•W.-OVERHEAD WIRES LeBlanc, 7 Haywood Avenue, So. TEST PIT Engineering by: Engineering Works, Inc. 12 West Crossfield Road Forestdole, MA 02644 (508) 477-5313 BENCHMARK SCALE 1 "=20' LEGEND Yarmouth Health Department APPOVED OWNER OF RECORD LEBLANC, ROBERT E & LEBLANC, MADELEINE M 7 HAYWOOD AVE. SOUTH YARMOUTH, MA 02664 Date �h N P ROck Rd F v LOCUS °�s Hill ° _ Mid-CtlP° Hwy Sr Route 6 y`°o LOCUS MAP NOT TO SCALE GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON an ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC F SYSTEM COMPONENTS NOT SHOWN ON THE PLAN -0.■-,�.1111 1a117, PROPOSED SEPTIC SYSTEM UPGRADE PLAN 45 FREEMAN ROAD, YARMOUTH PORT, MA Prepared for: Robert LeBlanc, 7 Haywood Avenue, So. Yarmouth, MA 02664 Engineering by: Engineering Works, Inc. 12 West Crossfield Road Forestdole, MA 02644 (508) 477-5313 Surveying by: JCEngineering, Inc. 2854 Cranberry Hwy. E.Wareham, MA 02538 (508) 273-0377 SCALE 1 "=20' DRAWN P.T.M. JOB. NO. 194-16 DATE 8/11/16 CHECKED P.T.M. SHEET No. 1 of 2 NOTE: TO PREVENT BREAKOUT, FINAL GRADE SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED D -BOX SHALL NOT BE AT, OR BELOW, EL.=96.5 FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED S.A.S. O INSTALL RISER & COVER PROPOSED S.A.S. SET TO 6" OF GRADE T.O.F=103.8± INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT / S F.G. EL.=103.0± F.G. EL.=101.0±S,4 F.G. EL.=101.2± %� F.G. EL.=101.0± / \� S % MAINTAIN 2% SLOPE OVER S.A.S. >S N ^� �+ ``� CO L = 37'(MAX.) 3'(max.) _, L = 6' 0,S=1% (MIN.) ®S=1% (MIN.) ®S=175(MW.) 4"SCH40 1. PVC - 4"SCH40 PVC 4"SCH40 PVC 2" LAYER OF 1/8" TO 1/2" �rJ 4' \C 6" DOUBLE WASHED STONE �a I 6' aaa�iaaa (OR APPROVED FILTER FABRIC) O 14" INV.=99.00 48" LIQUID pppp a pa aaaaaaa---3/4" TO 1-1/2" DOUBLE /EXISTING t�j , Ov 0� LEVEL ADD INV.=98.37 PROPOSED 4' 4.8' 4' WASHED STONE HOUSE(1145) m GARAGE _ • cns BAFFLE _ INV. -98.20 .... INV.=98.75 - 12.8' EFFECTIVE WIDTH - T.O.F.= 900 t 3 OUTLETS INV.- 96.00 - / PROPOSED SEPTIC TANK 2-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN CONNECT TO EXISTING SEWER PIPES AT H-10 RATED HOUSE, AT OR ABOVE, INV.=101.1 TOP CONC. ELEV.= 96.8± BREAKOUT ELEV.= 96.50 ®®®a SEPTIC LAYOUT NOTES: INV. ELEV.= 96.00 ®®®®p 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & aaaaaaaaaaa INVERTS EXITING HOUSE, PRIOR TO INSTALLATION.a®aaaBaaaaa BOTTOM ELEV.= 94.00 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND4' 2 x 8.5' _ .17.0' 4' TRUE TO GRADE ON A MECHANICALLY COMPACTED 4' OF NATURALLY OCCURRING EFFECTIVE LENGTH = 25.0' SIX INCH CRUSHED STONE BASE, AS SPECIFIED PERVIOUS MATERIAL IN 310 CMR 15.221(2). 5' (MIN.) ABOVE G.W. LEACHING SYSTEM SECTION ® ® ® ® 0 E3 E3 E3 Ea 3) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTTOM OF TEST PIT, EL.=87.2 = 1- ®®®®®®®®®®® 33" 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. d- W ® ® EO ® ® ® ® ® E3 E3 U N ULTEO ®®®®® Z SEPTIC SYSTEM PROFILE 102" DESIGN CRITERIA SOIL LOG 4" KNOCKOUT NUMBER OF BEDROOMS: 3 BEDROOMS DATE: AUGUST 3, 2016 20" DIA. COVER SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) SOIL EVALUATOR: PETER McENTEE PE(SE#1542) DESIGN PERCOLATION RATE: <2 MIN/IN WITNESS: AMY VON HONE R.S.HEALTH AGENT 0 x1__' 4" KNOCKOUT 4" KNOCKOUT 58" DAILY FLOW: 330 GPD ELEV. TP DEPTH DESIGN FLOW: 330 GPD 98'9 ® 0„ GARBAGE GRINDER: NO -not allowed with design LOAMY SAND 4" KNOCKOUT 10YR 4/2 LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 98.2 g 8 GPD/SF LOAMY SAND 500 GALLON CAPACITY, H-10 LOADING .74 10YR 5/6' CHAMBERS PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY 961 34„ PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED C PERC 24"/42" _ _ _ _ N.T.S. USE 2-500 GALLON LEACHING CHAMBERS IN SERIES PROPOSED SEPTIC SYSTEM UPGRADE PLAN SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES F -M SAND 2.5Y 6/6 45 FREEMAN ROAD, YARMOUTH PORT, MA SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. Prepared for: Robert LeBlanc, 7 Haywood Avenue, So. Yarmouth, MA 02664 BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. TOTAL AREA: 471.2 S.F. 87.2 140" Engineering by: Surveying by: SCALE DRAWN JOB. NO. .............................................................. PERC RATE <2 MIN/IN. "C" HORIZON Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 194-16 DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD NO GROUNDWATER ENCOUNTERED 12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET NO. Forestdole, MA 02644 E.Wareham, MA 02538 (508) 477-5313 (508) 273-0377 8/11/16 P.T.M. 2 Of 2