HomeMy WebLinkAboutEngineered Plans - 20166
BENCHMARK
OUTSIDE COR.
/BULKHEAD
EL. =102.14
411jlr(t
1�1 OF Nss9C��
o PETER T.
McENTEE
CIVIL
No. 35109
�<
<-qu�
x
99,70+
101,5
100.62
+
G
10022 x a—s
,'/STING LEACH PITS
BE PUMPED, FILLED WITH
ND & ABANDONED
N 80'24'30" E x 99,5
112.00'
+ 99161
i
-1* •99,63 edge of clearing
\ + 99.63\*C
, 7 x 9919
aS r GARDEN
— _°� -
;.� ..... + 100,11
.TJ 99,96 ISI
I
0
N 100.
92� x 100,42
PATIO
HOUSE(#8
.O.F.=100.?
x
100,55
– --EXISTING
CONTOUR
x 100.98
EXISTING SPOT GRADE
F971
PROPOSED CONTOUR
1N
EXISTING WATER SERVICE
—6. H. W.-- OVERHEAD WIRES
N
TEST PIT
eon
BENCHMARK
m
LEGEND
Yarmouth Health Department
EXISTING SEPTIC TANK
INV. (OUT)= 98.Of (VERIFY)
100,58
+ 100,587 cn
0
N Cfl
s r. o w
X7o "'
p csi
/ % / -o
PORCH
100,56 'y'9�� 100,39.`:..."' j
x
100,22
9 9,4 3
of pavement 99.66
MULFORD STREET
100.46
x
100,02
r4 I LOCUS MAP
Dates NOT TO SCALE
,/fpm. ,>- . lfe' >'
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
OWNER OF RECORD
REID, MARETTE
N
JOYCE ST
m
6�
MA 02664
N
z
eon
PLAN
m
0.0
STILES RD
m
z
Prepared for: Marette
y�o�
MULFORD ST
Engineering by:
,9
LOCUS
DRAWN
JOB. NO.
JAME
KEngineering, Inc.
1 "=20'
P.T.M.
JP pIGE
RD
12 West Crossfield Road
Forestdale, MA 02644
y
DATE
CHECKED
SHEET N0.
(508) 477-5313
vo�G
9/12/16
�JO
r4 I LOCUS MAP
Dates NOT TO SCALE
,/fpm. ,>- . lfe' >'
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
OWNER OF RECORD
REID, MARETTE
G
8 MULFORD STREET
SO. YARMOUTH,
MA 02664
PROPOSED
SEPTIC SYSTEM UPGRADE
PLAN
100,18
8 MULFORD
STREET, SOUTH YARMOUTH, MA
Prepared for: Marette
Reid, 8 Mulford Street, South Yarmouth,
MA 02664
Engineering by:
Surveying by:
SCALE
DRAWN
JOB. NO.
Engineering Works, Inc.
KEngineering, Inc.
1 "=20'
P.T.M.
208-16
12 West Crossfield Road
Forestdale, MA 02644
2854 Cranberry Hwy.
E.Wareham, MA 02538
DATE
CHECKED
SHEET N0.
(508) 477-5313
(508) 273-0377
9/12/16
P.T.M.
1 of 2
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SEPTIC TANK
SHALL NOT BE AT, OR BELOW, E'=97.5
INSTALL RISERS & COVERS OVER INLET &
FOR A DISTANCE OF 15' FROM THE EDGE
OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED D -BOX
OF THE PROPOSED S.A.S.
INSTALL RISER & COVER
PROPOSED S.A.S.
SET TO 6" OF GRADE
INSTALL RISER & COVER OVER ONE CHAMBER AND
T.O.F=100.93±
SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT
FB H
F.G. EL.=100.5± F.G. EL.=100.0± F.G. EL.=100.0±
F.G. EL.=100.0±
BATH BATH
BEDROOM DIN. RM.
������
20•I.D. DIA Z4'I.D. DIA
L 17'
® S=1% MIN. L = 5'
(MIN.) ® S=1% (MIN.)
KITCHEN GARAGE
za•ov.covea 4"SCH40 PVC 4"SCH40 PVC
2" LAYER OF 1/8" TO 1/2"
DOUBLE WASHED STONE
6'
R APPROVED FILTER FABRIC)
a®®SaBW
BEDROOM
LIV. RM. PORCH
14..
®0000®
043130003/4" TO 1-1/2" DOUBLE
ADD PROPOSED
GAS BAFFLE INV.=97.27 INV.=97.10
4' 5.2'WASHED STONE
_
INV.=98.0± D BOX
EFFECTIVE WIDTH = 12.8'
EXISTING 1500 GALLON SEPTIC TANK (VERIFY) 3 OUTLETS INV.=97.00
H-10 RATED
1 -500 GALLON LEACHING CHAMBER
FLOOR PLAN
EXISTING SURROUNDED
WITH STONE AS SHOWN
H-10 RATED
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE TOP CONC. ELEV.=97.8±
INVERTS, PRIOR TO INSTALLATION. BREAKOUT ELEV.=97.50
INV. ELEV.=97.00
4384343
MMMMMU WC660643
2) D -BOX SHALL BE SET LEVEL AND TRUE TO
134343®®436®a®e
on
1-11
GRADE ON A MECHANICALLY COMPACTED SIX BOTTOM ELEV.=95.00
INCH CRUSHED STONE BASE, AS SPECIFIED
4' 8.5' 4'
Tr----
IN 310 CMR 15.221(2). 4' OF NATURALLY OCCURRINGIR
EFFECTIVE LENGTH = 16.5'
PROP. SAS I
3) INSTALL INLET & OUTLET TEES AS REQUIRED. PERVIOUS MATERIAL
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE 5' (MIN.) ABOVE G.W.
N
-
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. ADJUSTED G.W., EL.=88.9
LEACHING SYSTEM SECTION
=
�.
SEPTIC SYSTEM PROFILE
'lots
.0,
SOIL LOG
SEPTEMBER 1, 20161
S r.
SOIL
WITNESS:
EVALUATOR: PETER McENTEE PE(SE#1542)
AMY VON HONE R.S. HEALTH AGENT
DESIGN CRITERIA
ELEV. TP DEPTH
EXIS/TING
NUMBER OF BEDROOMS: 2
99 90"
A LOAMY
HOUSE(118)SOIL
T.O.F. 100.93E
TEXTURAL CLASS: CLASS I (EFFLUENT LOADING RATE=0.74 GPD/SF)
DESIGN PERCOLATION RATE: <2 MIN/IN
SAND
2
10YR 4/2
= GARAGE
DAILY FLOW: 220 GPD
99,4 6"
B
/� J PORCH
LOAMY SAND
/
DESIGN FLOW: 220 GPD (MINIMUM REQUIRED)
10YR 5/8
GARBAGE GRINDER: NO -not allowed with design
97.1 34"
C
LEACHING AREA REQUIRED: (220 GPD) = 297.3 SF/4"
24 4"/42"
.74 GPD/SF
SEPTIC LAYOUT
EXISTING SEPTIC TANK: 1500 GALLON CAPACITY
MED. SAND
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED
2.5Y 6/4
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
USE 1-500 GALLON LEACHING CHAMBER SURROUNDED
8 MULFORD STREET, SOUTH YARMOUTH, MA
WITH 3/4" to 1-1/2" DOUBLE WASHED STONE -ALL SIDES
SIDEWALL AREA: 2(12.8' + 16.5') x 2 = 117.2 SF
Prepared for: Marette Reid, 8 Mulford Street, South Yarmouth,
MA 02664
BOTTOM AREA: 12.8' x 16.5' = 211.2 SF
88.9 132"
Engineering by:
Surveying by:
SCALE
DRAWN
JOB. NO.
TOTAL AREA: .......................................... I ................... 328.4 SF
NIC./INCH
Engineering Works, Inc.
JC Engineering, Inc.
N.T.S.
P.T.M.
208-16
NO GROUNDWATER OANTERED
12 West Crossfield Road
Forestdole, MA 02644
2854 Cranberry Hwy.
E.Warehann, MA 02538
DATE
CHECKED
SHEET NO.
DESIGN FLOW PROVIDED: 0.74 GPD/SF(328.4 SF) = 243.0 GPD
(508) 477-5313
(508) 273-0377
912/16
P.T.M.
2 Of 2