HomeMy WebLinkAbout83-2036 - Site Plan002Ln
ROOF RUN OFF
c'; IF USING GUTTERS PROVIDE DRY WELLS OTHER -
o_ WISE PROVIDE STONE TRENCH FOR DRIP LINE
Do
LD
Cd MAXIMUM BUILDING HEIGHT
o GRADE AT STREET SIDE OF BUILDING=19.5
le 19.5 + 35=54.5=MAX. PEAK ROOF
54.5-(33'-11.5"*)=TOP FOUND. -20.5
*DESIGN DISTANCE FROM PEAK TO TOP FOUND.
RIVERFRONT
ALL OF LOT I'S IN THE RIVERFRONT
NEW CONSTRUCTION BEYOND EXISTING FOOTPRINT:
WINDMILL & DECK (RAISE) 661±S.F.
STONE PATIO 846±S.F.
HOUSE, DECK, STEPS 1290±S.F.
TOTAL NEW AREA 2797±S.F.
gP
HARDSCAPE PATIO
DESIGN )
(SEE PHILIP CHENEY PLAN)--,,,
LAPLAN) \ � 1
_� 6,9
4" PVC
10.5
11.2
S.F.
r 125
v �N 1/.0 v
REMOVE SPRUCETREE / t \
17.2
Qj
PROPOSED FENCE V'0 2 / 43 ( i�� apo
ALONG TOP BANK
_ 7
/ 91,
'.5 n
1 7
1,6 �. / 4
a 7
1,3 `Z_ yv Cb 3.6 `S .
0�0o,�h 1 ��
.0
5
• 12.03
. 14.::
N /F
KILMAN
Y 17.0
zG
17.7
PROPOSED WATER
LONG STANDING
OCCUPATION
0.00
17.48
RAISE IN PLACE EXISTING
ONE BEDROOM DWELLING
ON PIERS PER MCKENNA
ENGINEERING CONSULTANTS PLAN
WITH BOTTOM OF LOWEST HORI-
ZONTAL BEAMS TO BE AT
ELEVATION 14 NAVD88
PLUMBER TO INSTALL EJECTOR PUMP
CAPABLE OF 40 GPM ® 14.2' OF HEAD.
A NON GRINDER PUMP NEEDS TO PASS 2" DIAM. SOLIDS
OR, A GRINDER PUMP MEETING PLUMBING CODE
MAY BE USED ONLY IF TWO COMPARTMENT
1500 GALLON SEPTIC TANK IS USED
"'fBENCH MARK --TOP & CENTER OF
CONC. BOUND= 30.22 ASSIGNED
13,9
9
N
N /F
COFFEY
15.3
ci'18.1
PROPOSED 2390±S.F.
4 BEDROOM DWELLING
6a WITH 241±S.F. EN-
CLOSED DECK
32 EDGE PROP.
DRIVE
18.5
j G
0�;�17.91 C\
17 {. 7.7
i \
OO �17.4
17.43 x 17 V 31
17.97//
/71�)
Z 4 CO)
ZONING DISTRICT:
LEGEND
TH 1
TEST HOLE LOCATION, NUMBER
-W-
WATER LINE MARKINGS
E
OVERHEAD ELECTRIC WIRES (IF SHOWN)
-G--
GAS LINE MARKINGS
9.5 x 18,3
EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT)
�G---
EXISTING CONTOUR
8-"
PROPOSED CONTOUR
ELEVATIONS SHOWN ARE NAVD88 f0.1' USING VERTCOM.
UTILITY POLE (IF SHOWN)
®
EXISTING DRAINAGE CATCH BASIN
x -
FENCE (IF SHOWN, NOT ALL SHOWN)
0
TREE (IF SHOWN, NOT ALL SHOWN)
----------
PROPOSED WORK LIMIT
REV. 10/23/2015 --PATI O
Y 17.0
zG
17.7
PROPOSED WATER
LONG STANDING
OCCUPATION
0.00
17.48
RAISE IN PLACE EXISTING
ONE BEDROOM DWELLING
ON PIERS PER MCKENNA
ENGINEERING CONSULTANTS PLAN
WITH BOTTOM OF LOWEST HORI-
ZONTAL BEAMS TO BE AT
ELEVATION 14 NAVD88
PLUMBER TO INSTALL EJECTOR PUMP
CAPABLE OF 40 GPM ® 14.2' OF HEAD.
A NON GRINDER PUMP NEEDS TO PASS 2" DIAM. SOLIDS
OR, A GRINDER PUMP MEETING PLUMBING CODE
MAY BE USED ONLY IF TWO COMPARTMENT
1500 GALLON SEPTIC TANK IS USED
"'fBENCH MARK --TOP & CENTER OF
CONC. BOUND= 30.22 ASSIGNED
13,9
9
N
N /F
COFFEY
15.3
ci'18.1
PROPOSED 2390±S.F.
4 BEDROOM DWELLING
6a WITH 241±S.F. EN-
CLOSED DECK
32 EDGE PROP.
DRIVE
18.5
j G
0�;�17.91 C\
17 {. 7.7
i \
OO �17.4
17.43 x 17 V 31
17.97//
/71�)
Z 4 CO)
ZONING DISTRICT:
R25
FRONT YARD:
30'
SIDE YARD:
15'
REAR YARD:
20'
LOT COVERAGE:
25%
Im
-------------
SLAB=15.3
1
THIS PLAN IS A VALID COPY ONLY IF IT BEARS
AN ORIGINAL RED STAMP AND SIGNATURE.
HEALTH AGENT APPROVAL
DATE
14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0
TEST HOLE DATE: November 5, 2014 8"
PERFORMED BY: Ron Cadillac,, Soil Evaluator
WITNESSED BY: Amy Von Hone, RS, CHO
PERC RATE: <2'-00"/inch (Cl &C2 layers)
SOIL SURVEY(1993): Carver coarse sand 30"
FOUND=20,5 GEOLOGIC MAP(1986): Harwich outwash plain deposits
�-
2 Compartment Tank
Needed If grinder Invert 15.10 3 DRY WELLS (H-20) 64"
Invert .15.85 Ejector Pum used WITH TWO H-10 COVERS
Use Gas Baffle Invert 14.33
Use Gas Baffle Proposed
Two 'H-10 COVERS Proposed Top ponc.=15.0
S=1 /4"/ft Top Peastone/
Filter Cloth=14.5
1500 Gal. S=1 /4"/ftMax Screened
S=1 /8" /ft -- 6' Went
17.6
A layer 10yr 3/3
sandy loom
B Payer 10yr 5/6
sandy foam
15.1
C1 layer 2.5y 6/4
fine to med.
loamy sand
123
C2 layer 2.5y 6/6
med, coarse sand
(trace fines)
no water 62
Invert 15.35 Septic Tank 11137
Proposed H-20 -------- ---
T TEST HOLE 2
Invert 14.50 Invert 14.1712.17
9.6 5.97 Bottom DEPTH (inches) ELEV.(fei
6 Stone Or compact Proposed
I I i Proi N osied ' i
1
, 1
NOTES
JOB NO. Y14-37
015
30'-1
PALMER2.DWG
1
1.
LOCUS 1S A.M. 22, PARCEL 59.
FB 30/63 SB 13/62
2.
ELEVATIONS SHOWN ARE NAVD88 f0.1' USING VERTCOM.
1' 5,
3.
LOCUS IS IN FLOOD ZONES: VE(EL.13), AE(EL.11), X(0.2% RISK), X (OUTSIDE 0.2% RISK)
Oi
ON FIRM PANEL 0569J DATED JULY 16, 2014. BOUNDARIES SHOWN ARE SCALED.
4.
ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED)
5.
MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER.
Qa' Sao
6.
COMPONENTS TO BE AASHTO H-10, UNLESS NOTED.
a
7.
INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14".
$
8.
IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW
D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET.
NOT '
9.
DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST- BE PROVIDED.
SCALE
LEACH AREA
COVERS: BUILD UP H-10 COVERS TO 6" BELOW GRADE --2 ON TANK, 2 ON D -BOXES, 2 ON LEACHING.
GARBAGE GRINDER:
10.
STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP.
LOCATION MAP
11.
IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND,
550 GPD
WITH
CONTACT THE BOARD OF4 HEALTH; OR R.J. CADILLAC.
64"
12.
IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING
TEST HOLE 1
APPROX. 3' OF STONE ON THE
IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3):
BOTTOM LEACHING AREA:
13.
PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN
[(47.5' X 11')]
LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT.
DEPTH (inches) ELEV.(fee
14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0
TEST HOLE DATE: November 5, 2014 8"
PERFORMED BY: Ron Cadillac,, Soil Evaluator
WITNESSED BY: Amy Von Hone, RS, CHO
PERC RATE: <2'-00"/inch (Cl &C2 layers)
SOIL SURVEY(1993): Carver coarse sand 30"
FOUND=20,5 GEOLOGIC MAP(1986): Harwich outwash plain deposits
�-
2 Compartment Tank
Needed If grinder Invert 15.10 3 DRY WELLS (H-20) 64"
Invert .15.85 Ejector Pum used WITH TWO H-10 COVERS
Use Gas Baffle Invert 14.33
Use Gas Baffle Proposed
Two 'H-10 COVERS Proposed Top ponc.=15.0
S=1 /4"/ft Top Peastone/
Filter Cloth=14.5
1500 Gal. S=1 /4"/ftMax Screened
S=1 /8" /ft -- 6' Went
17.6
A layer 10yr 3/3
sandy loom
B Payer 10yr 5/6
sandy foam
15.1
C1 layer 2.5y 6/4
fine to med.
loamy sand
123
C2 layer 2.5y 6/6
med, coarse sand
(trace fines)
no water 62
Invert 15.35 Septic Tank 11137
Proposed H-20 -------- ---
T TEST HOLE 2
Invert 14.50 Invert 14.1712.17
9.6 5.97 Bottom DEPTH (inches) ELEV.(fei
6 Stone Or compact Proposed
I I i Proi N osied ' i
A layer 10yr 3/3 17.
sandy loam
B layer 10yr 5/6
sandy loam
15.
C1 layer 2.5y 6/4
fine to med.
loamy sand
12.
C2 layer 2.5y 6/6
med. coarse sand
(trace fines)
[ ( + no water 6.3
USE 4 DRY WELLS CENTERED IN 10' 137
DESIGN CAPACITY: 559.8 GPD X 50.5' X 2' LEACH AREA=5.52 GPD.
[(522:5 SF + 234 SF) X .74 GPD/SF]
SITE PLAN
FOR
DAVID & MELISSA PALMER
LOT 4, 33 :CREST CIRCLE, WEST YARMOUTH, MA
OCTOBER 1, 2015 SCALE: 1 "=20'
RONALD J. CADILLAC, PLS, RS, P.C.
PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN
P.O. BOX 258
WEST YARMOUTH, MA 02673
(508) 775-9700
C)2015 BY R.J. CADILLAC PAGE 1 OF 1
1
, 1
11
015
30'-1
r__
1
Bottom TH1=6.225'
1' 5,
,.
$
CF
<If
ltstimoted High Groundwater=2.5 NAVD88
DESIGN DATA
28"
BEDROOMS:
5
LEACH AREA
V
GARBAGE GRINDER:
No°'
USE
3 DRY WELLS SET 7' APART 60"
a`
REQUIRED CAPACITY:
550 GPD
WITH
4' OF STONE ON THE ENDS
64"
SEPTIC TANK:
1500 GAL.
AND
APPROX. 3' OF STONE ON THE
BOTTOM LEACHING AREA:
522.5 SF
SIDES, FOR A 47-6" LONG BY 11'
[(47.5' X 11')]
WIDE
BY -2' DEEP LEACH AREA.
SIDE LEACHING AREA;
234 SF
RESERVE
2 11' 47 5') X 2' DEEP)]
^
A layer 10yr 3/3 17.
sandy loam
B layer 10yr 5/6
sandy loam
15.
C1 layer 2.5y 6/4
fine to med.
loamy sand
12.
C2 layer 2.5y 6/6
med. coarse sand
(trace fines)
[ ( + no water 6.3
USE 4 DRY WELLS CENTERED IN 10' 137
DESIGN CAPACITY: 559.8 GPD X 50.5' X 2' LEACH AREA=5.52 GPD.
[(522:5 SF + 234 SF) X .74 GPD/SF]
SITE PLAN
FOR
DAVID & MELISSA PALMER
LOT 4, 33 :CREST CIRCLE, WEST YARMOUTH, MA
OCTOBER 1, 2015 SCALE: 1 "=20'
RONALD J. CADILLAC, PLS, RS, P.C.
PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN
P.O. BOX 258
WEST YARMOUTH, MA 02673
(508) 775-9700
C)2015 BY R.J. CADILLAC PAGE 1 OF 1