HomeMy WebLinkAboutDOA - 35 Echo Rd - Site & Sewage PlanGENERAL NOTES:
A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM
UNLESS H-20 COMPONENTS ARE USED.
B.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM A5 DESIGNED UN-
LE55 CONSTRUCTED AS SHOWN. ANY CHANGES SHAD. BE APPROVED IN WRITING.
C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL
UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT Or WORK.
CONSTRUCTION NOTES:
1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE.
TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH.
2.) 5EPTIC TANK(8), GREASE TRAP(5), D05ING CHAMBERM) AND DISTRIBUTION
BOX(E5) SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS. BEEN MECHANICALLY
COMPACTED, OR ON A G INCH CRUSHED STONE BASE.
3.) SEPTIC TANKS) SHALL MEET A5TM STANDARD C 1 127-93 AND SHALL HAVE
AT LEAST THREE 20' DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT-
TOM OF THE 5EPTIC TANK TO THE FLOW LINE SHALL BE 48.
4.) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A. MINIMUM OF 0
ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE
CENTERUNE OP THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE.
5.) RAI5E COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST
CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN 6" OF
FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT.
6.) PIPING SHALL CON515T OF 4' SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL
BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN I %.
7.) DISTRIBUTION LINES FOR 501L ABSORPTION SYSTEM (A5 REQUIRED) SHALL BE
4" DIAMETER SCHEDULE 40 PVC LAID AT 0,005_ FrIFT. LINE SHALL BE CAPPED
AT END OR AS NOTED.
8.) OUTLET PIPES FROM DI5TRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST
2' BEFORE PrTCHING TO 501L ABSORPTION SYSTEM. WATER TEST DISTRIBUTION
BOX TO A55URE EVEN DISTRIBUTION.
9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM BUMP OF W MEASURED BELOW
THE OUTLET INVERT.
10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CON515T OF 314' TO
11-1/2' DOUBLE WASHED NATIVE STONE FREE OF IRON, FINES AND DUST AND SMALL
BE INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE
501L ABSORPTION SYSTEM. BASE AGGREGATE SHALL BE COVERED WITH A 2'
LAYER OF 118" TO 1/2" DOUBLE WASHED NATIVE STONE FREE OF IRON, PINES AND DUST.
1 1.) VENT SOIL ABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET:
WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS,
TURNING AREAS OR OTHER IMPERVIOUS. MATERIAL:. OR. WHEN PRESSURE DOSED.
12.) 501L ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9" OF
CLEAN MEDIUM SAND (EXCLUDING TOPSOIL).
13.) FINISH GRADE SHALL BE A MAXIMUM OF 36' OVER THE TOP OF ALL SYSTEM
COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, DOSING CHAMBER
AND SOIL ABSORPTION SYSTEM. SEPTIC TANKS SHALL HAVE AMINIMUM COVER
OF 9".
14.) FROM THE DATE OF INSTALLATION OF THE SOIL AB50RFTION SYSTEM UNTIL
RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL ABSORP-
TION SYSTEM SHALL BE STAKED: AND FLAGGED TO PREVENT THE USE OF SUCH.
AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM. -
15.) THE BOARD OF HEALTH SHALL REQUIRE INSPECTION OF ALL CONSTRUCTION
BY AN AGENT OF THE BOARD OF HEALTH (OR THE DESIGNER IF TH15 SYSTEM RE-
QUIRE5 A. VARIANCE) AND MAY REQUIRE 5UCH PERSON TO CERTIFY IN. WRITING
THAT ALL WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE TERMS OF THE
'PERMIT AND APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS'REQUESTED.
I G.) INSTALL A 40 mA HDPE LINER FROM EL 20.7 TO EL 18.7 AS SHOWN ON PLAN.
17.) 501L REMOVAL: ALL A AND B LAYERS SHALL BE REMOVED FOR DISTANCE OF
Or 5`FR0M THE 501L ABSORPTION SYSTEM DOWN TO THE CLEAN SAND EL 17.7""
AREA TO BE BACKNIL ED WITH CLEAN SAND AND COMPACTED TO MINIMIZE
SETTLING.
FLOW PRUFI LE:
SOIL TEST LOGS:
DEPTH FROM
SURFACE
(INCHES)
SOIL
HORIZON
-
SOIL
TEXTURE
(U5DA)
501L
COLOR
- (MUN5
501L
MOTTLING
-
OTHER
0
Cf
Fill
NA
NONE
G.W.
8-31
I OYR6/6
Loamy fine Sand
I OYR6 G
NONE
PERC P 3I"
31-138
Cl
Fine Sand
I CYR71r,
NONE
RATE: <2MIWIN
-W-
WATER SERVICE LINE
--o-
OVERHEAD UTIL11YSERVICE
-U-
UNDERGROUND UTILITY SERVICE
-G-
ro
DEPTH FROM
SURFACE
501L V
HORIZON
SOIL
(I 51 on)�
501L
COLOR
501L - OTHER
MOTTLING
MOTTLING
0-8
E
Loamy Fine Sad
1 OYR5/2
NONE G.W. A 123"
8-36
B
1oamy Fine Sand
I OYR6/6
NONE
36-132
GI
Fine Sand
IOYR7/6
NONE
EXISTING SPOT GRADE
Proposed EL=22.5±
24x5
PROPOSED SPOT GRADE
-W-
WATER SERVICE LINE
--o-
OVERHEAD UTIL11YSERVICE
DATE OF TESTING: 8-15-1 G
PERCOLATION. RATE: LE55 THAN -2_MIWINCH IN.'C". LAYERS..
WITNESSED BY: MATTHEW T. FARRELL, Err, J.M. O'REILLY 4 ASSOCIATES, INC.
AMY VON HONE, AGENT, YARMOUTH HEALTH _DEPARTMENT
USE -A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF 501L ABSORPTION SYSTEM.
HIGH GROUNDWATER LEVEL CALCULATIONS:
Depth To Water Table (8-18-16): 10.4 FEET, EL -10.5
Appropriate Index Welt: MIW-29
Water Level Range Zone: B (0-3')
Current Depth To Water Level For Index Well (8116): 9.6'
. Water Level Ad)u5tment: 3.9'
Estimated Depth To High Water: 6.5 FEET, FL= 14.4
ZONING CLA551FICATION
ZONE K-25 (RESIDENTIAL)
MINIMUM AREA 25,000 S.F.
MINIMUM FRONTAGE - 150 FEET
FRONT YARD SETBACK 30 FEET
SIDE YARD SETBACK 15 FEET
REAR YARD SETBACK 20 FEET
MAXIMUM 13UILDING HEIGHT 35 FEET'
MAXIMUM BUILDING COVERAGE 25%
'BUILDING HEIGHT MEASURED STREET
SIDE OF FOUNDATION SEE TABLE 203.4.2,
YARMOUTH ZONING BY-LAW
PPOF05FD BUILDING COVERAGE -
PROP05ED DWELLING 1,4125F±-
SHED - _ ^975F•S -_ <
TOTAL 1,509. Sf:t
boldmq-Area- 1,509
Lot Area '100).9.3r 100)= I G.1 %
SYSTEM DESIGN CALCULATIONS:
a°
SEWAGE DE51GN FLOW: QO
2 BEDROOM DWELLING @ 1 10 GPD = 220 GPD py
LEACHING CAPACITY REQUIRED: OyP�
3 BEDROOM (MAX.) @ 1 10 GPD - 330 GPD REQUIRED ,�0\
SEPTIC TANK CAPACITY REQUIRED::
DAILY PLOW = 330 GPD @ 200 " = 660 GAL. REQUIRED A00�x
SEPTIC
150GALLON KCSEPTIC CTANK (MND ALLOWED)
LEACHING CAPACITY PROVIDED: O
N (1) 40. X 12.0'X • LEACHING FIELD CAN LEACH:
Vt= ((40.0' X 12.0)] 0.74 GPD/5F=355.2 GPD
355 GPD>330 GPD REQUIRED -
NOTE: A GARBAGE DISPOSAL 15 NOT PERMITTED WITH THI5 DESIGN
INSTALL:
ONE 1) - 1500 GALLON SEPTIC TANK
ONE (1) -.3 OUTLET DISTRIBUTION BOX (H-20 Rated)
ONE (1) - 40.0 X 12.0' X 8' NATIVE STONE LEACH FIELD
Existing Parking Area
TO BE REMOVED
PROPOSED 40 MIL HDPE '
LINER 5EE NOTE I G R1
a
O 19.7.
�0O
'. Gb
Ex15t1ng Sewage 5y5temF-
i 21.2 q�
(Per Health Records) 6, 22 9'
TO BE REMOVEDTP
h
V \q'
9.6
4
18.4
18.2
r0•�. t N
.a 2p,.(3 OQO00 �s�ys� �,�� `� rr.s\ �l• � �` p �1 ro �c 8a, ,
7.4 R4r�O��y'���'L�a,'�, �•� v � `'� �\ �.S Np / h/NG C
h r {"rr' , \ N
20.7 �
/
�,
4, S•9•;
NOT TO SCALE
THREE (3) COVERS
TOTAL
24" DIAMETER CONCRETE COVERS TWO 5EF-FIC
TANK AND I DBOX
PAGE 187
RA15ED TO WITHIN G' OF FINISH
A55E550R5' MAP 47 PARCEL 2G
TOP OF FOUNDATION
GRADE (OR AS NOTED) --
- 32
EL -25.00
(5EE NOTE #5)
32
'
Proposed EL-- 23.20
EXISTING SPOT GRADE
Proposed EL=22.5±
24x5
PROPOSED SPOT GRADE
-W-
WATER SERVICE LINE
--o-
OVERHEAD UTIL11YSERVICE
-U-
UNDERGROUND UTILITY SERVICE
-G-
ro
(;
TP
I�1.
.224-
SEPTIC TANK
DB
D15TRIBUTION BOX
20
25/ tL1110' 14' ' \210
20 0 2025 2920/
3"
4b' 2' DROP
GAS BAFFLE -
I Longest Run
12'---{ 1500 GALLON
DB -3
5EPTIC TANK D -BOX LEACHING P1Ei;D
H-20 40.0 x 12.0 x 8'
X
RsJ-)(1e.9
. 'k am 20.4
LOT
rea=9,3G
86 5F'
.00 I � g
23.9 N
OCV
O
30X
24. a
.>
24.9 6� �'
40 PVC SAS PLAN VIEW
INSPECTION PFORTr
18' . #5, REBAR. SCALE: I'
FUTURE LOCATION BENCHMARK:
Imposed EL- 22.2 (21.4 MINIMUM) - - (1988 NAVDofPrNaiIDaNm 3.6i'
2' LAYER OF 118• - 1 /2' 5TONE
be - 1-112• STONE
PLAN .
19. 0 SCALE 1"=20'
INSPECTION NOTE: THIS AREA 15 SERVED
5.1'± PRIOR TO FINAL INSPECTION BY THE ENGINEER, SYSTEM BY TOWN WATER.
NEEDS TO BE. COMPLETE INCLUDING BUILDUP FOR COVERS.
--- EL= 14.4HIGH GROUNDWATER 0 20 40 6o
3.9'
-l- - EL= 10.5 0135ERVED.GROUNDWATER 8/18116 - SCALE 1"=20'
LOCU5
Yarmouth,
MA
Big Sandy
Pond
P'05�-' NOT TO SCALE
PLAN BOOK I
10 PAGE 5
DEED BOOK 13073
PAGE 187
A55E550R5' MAP 47 PARCEL 2G
LEGEN D
- 32
EXISTING CONTOUR
32
PROPOSED CONTOUR
X 12.34
EXISTING SPOT GRADE
24x5
PROPOSED SPOT GRADE
-W-
WATER SERVICE LINE
--o-
OVERHEAD UTIL11YSERVICE
-U-
UNDERGROUND UTILITY SERVICE
-G-
GAS SERVICE LINE
TP
TEST HOLE/ BORING LOCATION
SrS
SEPTIC TANK
DB
D15TRIBUTION BOX
SAS
SOIL A1350P.PTION 5Y5TEM
Reserve
RESERVED FOR FUTURE
CQ>
UTILITY POLE
®
CATCH BA51N
FIRE HYDRANT
®
WELL
®
DRAINAGE MANHOLE
tl
CONCRETE BOUND, FOUND
-..cGATaQPOF.BANK-.__
rO z -x-
UMIT OF WORK
FENCE
EDGE OF CLEARING
ting 1000 Gallon Septic Tank
BE REMOVED
ting 2 Bedroom Dwelling
BE REMOVED
)POSED.GA5 SERVICE
)POSED WATER SERVICE
)POSED GRAVEL DRIVEWAY
Muncey Residence
c/o Jim Hagerty, RecF, Cape Cods Home Builder, PO Box 186, West Dennis, MA 02670
51TE AND SEWAGE D15F05AL 5Y5TEM DE51GN
35 Echo Road, Yarmouth; 'MA
J.M. OTEILLY & .ASSOCIATES, INC..
Professional Engineering & Land Surveying Services
1575 Main Street - Route 6A
P.O. Box 1773
(508)896-6801 Office Brewster; MA 02631 (508)696=6602 Pax
DATE: 5CALE: BY: CHECK: OB JNUMBER:
91GI I G As Noted MTF JMO I JMO-8223