Loading...
HomeMy WebLinkAboutDOA - 7 Makepeace Lane - Site PlanACCESS COVERS TO WITHIN 6' OF FIN.GRADE 25.9' SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE PRECAST H-10 RISERS (TIP.) 2°0 4"05CH40 PVC PIPES LEVEL 1ST 2' EXISTING *22.05'± 10" 1000 GAL H-10 14 ' f*21.3 TEE SEPTIC TANK TEE f*21.14' ' (RE -USE)-- ° GAS BAFII..E ..: .000000000°. 21.02' 20.85' -4'— ENDS ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM BLOCKS OR MORTAR ALL PRECAST RISERS COMPONENTS H-10 (TYP.) NV `- 43111261 18.75' 3/4 1-1/2" DOUBLE WASHED STONE 4' H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. (3) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.5' X 12.83' UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS COMPACTION. (15.221 [2]) PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM (CONFIR SEPTIC TANK INVERT ELEVATIONS NO LOWER THAN THAT SHOWN) (—Lx SLOPE) (-L-% SLOPE) " FOUNDATION- EXIST. - SEPTIC TANK 12' D' BOX 12' LEACHING FACILITY 13.75 BOTTOM TH-1 **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT NO GROUNDWATER FOUND _ 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE. LEGEND- EGEND99— 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 1OYR 2/1 TEST HOLE 2% SLOPE SLOPE OF GROUND B UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN ORAWM TEST HOLE LOGS ARNE H. OJALA, PE, SE ENGINEER.. WITNESS: PHIL RENAUD DATE: NOVEMBER 24, 2009 PERC. RATE = < 2 MIN/INCH CLASS 1 SOILS C2 FS 74" 2.5Y 6/4 X' C3 MS 123" 1 13.75' NO GROUNDWATER ENCOUNTERED 98-357 0 0! NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE NTH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5 BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. ' BUMPED I CLEAN 0 10 20 30 40 50 FEET #1\ UAIL UANILL A. UJALA, t -.L., r.L.J. nNG R DRIP ELEV. Q 0" 24.0' A LS 1OYR 2/1 6" B MCS 36" 1OYR 5/6 21.0' C1 1 PERC MS 1OYR 6/4 X, C2 FS 74" 2.5Y 6/4 X' C3 MS 123" 1 13.75' NO GROUNDWATER ENCOUNTERED 98-357 0 0! NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE NTH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5 BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. ' BUMPED I CLEAN 0 10 20 30 40 50 FEET #1\ UAIL UANILL A. UJALA, t -.L., r.L.J. nNG R DRIP LOCUS MAP NOT TO SCALE ASSESSORS MAP 41 PARCEL 55 LOCUS IS WITHIN FEMA FLOOD ZONE "C" ZONING: R-25 F: 30' S: 15' R: 20' PROPOSED LOT COVERAGE: 22.7% YSTEM DESIGN: RBAGE DISPOSER IS NOT ALLOWED 51GN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD A 440 GPD DESIGN FLOW 3TIC TANK: 440 GPD (2) = 880 -USE EXISTING 1000 GAL. SEPTIC TANK %CHING: ES2 (33.5 + 12.83) 2 (.74) = 137 GPD TTOM 33.5 x 12.83 (.74) = 318 GPD TAL: 614 S.F. 455 GPD E (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) 'H 4' STONE ALL AROUND DROVED DATE BOARD OF HEALTH , MA TITLE 5 SITE PLAN OF 7 MAKEPEACE LANE WEST YARMOUTH PREPARED FOR H. TABACHNICK 2009 REV. NOVEMBER 12/15 /09 (CALCS SHED) I off 508-362-4541 fax 508-362-9880 downcope.com down cope a fleerin.0, Inc. civil engineers land surveyors 939 Moin Street ( Rte 6A) YARMOUTHPORT MA 02675 98-357.DWG(SBO) I r 1 LOCUS MAP NOT TO SCALE ASSESSORS MAP 41 PARCEL 55 LOCUS IS WITHIN FEMA FLOOD ZONE "C" ZONING: R-25 F: 30' S: 15' R: 20' PROPOSED LOT COVERAGE: 22.7% YSTEM DESIGN: RBAGE DISPOSER IS NOT ALLOWED 51GN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD A 440 GPD DESIGN FLOW 3TIC TANK: 440 GPD (2) = 880 -USE EXISTING 1000 GAL. SEPTIC TANK %CHING: ES2 (33.5 + 12.83) 2 (.74) = 137 GPD TTOM 33.5 x 12.83 (.74) = 318 GPD TAL: 614 S.F. 455 GPD E (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) 'H 4' STONE ALL AROUND DROVED DATE BOARD OF HEALTH , MA TITLE 5 SITE PLAN OF 7 MAKEPEACE LANE WEST YARMOUTH PREPARED FOR H. TABACHNICK 2009 REV. NOVEMBER 12/15 /09 (CALCS SHED) I off 508-362-4541 fax 508-362-9880 downcope.com down cope a fleerin.0, Inc. civil engineers land surveyors 939 Moin Street ( Rte 6A) YARMOUTHPORT MA 02675 98-357.DWG(SBO)