Loading...
DOA - 10 Railroad Ave - Site PlanN ACCESS COVERS MUST BE WITHIN 6. OF FINISH GRADE \FIRST 2' TO GENERAL NO TES : BE LEVEL 100.7 OAS 9- MINIMUM. 3- MAXIMUM COVER MIN 2- OF PEASTONE OR FILTER FABRIC 3/4' - 1 I/2- DIA. DOUBLE WASHED STONE 3 OUTLET 3-500 GAL LEACHING CHAMBERS D-aox W/4' STONE AROUND. 12.8'w x 33.5'1 x 2'd 1500 GALV6- H-20 SEPTIC TANK H-20 CRUSHED STONE OR COMPACTED BASE PROFILE : Nor TO SCALE VARIANCES REQUIRED: TOWN OF YARMOUTH SUBSURFACE SEWAGE DISPOSAL REGULATIONS REGULATION 3.7: LOCATION OF DISPOSAL FACILITIES !00' IS REQUIRED BETWEEN THE SAS AND A WETLAND. 94' IS PROVIDED TO THE PRIMARY SAS. A 6' VARIANCE IS REQUESTED. 83' IS PROVIDED TO THE RESERVE AREA. A 17' VARIANCE IS REQUESTED. L INVERT EL E VA T I ONS : DESIGN CRITERIA: GENERAL NO TES : INVERT AT BUILDING: 100.7 DESIGN FLOW: SOIL TEXTURAL CLASS - I1 INVERT IN SEPTIC TANK: 100.5 3 BEDROOMS AT l!0 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION INVERT OUT SEPTIC TANK: 100.25 BEDROOM EQUALS 330 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. INVERT IN DIST. BOX: 99.77 THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- x-40.4 INVERT OUT DIST, BOX: 99.6 NO GARBAGE GRINDER 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS STANDING 14-20 WHEEL LOADS. SET. SEE SITE PLAN. INVERT IN LEACH CHAMBER: 99.4 W/4' STONE AROUND, A-614 S.F. SEPTIC TANK REQUIRED: 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR BOTTOM OF LEACH CHAMBER. 97.4 330 G.P.D. X 200% - 660 GAL, 3. ALL CONSTRUCTION METHODS AND MATERIALS AND ADJUSTED GROUND WATER: N/A SEPTIC TANK PROVIDED: 1500 GAL. MIN. MAINTENANCE OF THE SEPTIC SYSTEM SHALL OBSERVED GROUND WATER: N/A CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOTTOM OF TEST HOLE s3: 84.5 SOIL ABSORPTION SYSTEM REOUIRED: BOARD OF HEALTH REGULATIONS. r� \ \ \ CBLOH FND 0� "MAPLE 36'MAPLE Fg -----'- 18 NO / \r3't, 1 145.60- W / 36'MAPLE r 02.3 0 02.2 l / TP12 # �! EXISTING BUILDING l tj / CESSPOOL SOIL REMOVAL \ \ PROPOSED THREE J \ v W BEDROOM DWELLING J /i 1, _D:-- 5 I SEE NOTE 10. _ I1W 36A/41 h , T ::..> G .:..:. L O T AREA G G 9.108+ S.F.010 +/02.3 V O J-500 GALLON a \ \ / I_ LEACHING CHAMBERS' w n_, \ \ ``- /I _ _ _ , • W/4" STONE AROU,/i0 io0.8 GRAVEL DRIVEWAY \® TPa4 ISOO'GALLON \ ', 101..1 +102,r 158.14 2 MAPLE/ 6.01 .tV /y0 --_ \ 1 �� / +/0,1.4 / STK/TCRfN6 l --_-_ -- __STK/TCK FND -- \CBlOH FND -Iaa-------1 // / / _--- i , / / l EW 2 LOCUS MAP CONSERVATION NO TES : I. THE WORK LIMIT SHOWN SHALL BE FITTED WITH A SILT FENCE AS REQUIRED BY THE CONSERVATION COMMISSION. THE FENCED WORK LIMIT SHALL CONSIST OF A CONTINUOUS, STAKED. DUG -1N FABRIC SILT FENCE. THE FENCE SHALL REMAIN IN PLACE UNTIL THE DISTURBED GROUND IS STABILIZED COMPLETELY. PROVIDE ALTERNATE SILT FENCE SUCH AS STAKED STRAWBALES IF NEEDED AS DIRECTED BY THE CONSERVATION COMMISSION. 2. NO CONSTRUCTION RELATED ACTIVITY SHALL OCCUR ON THE WETLAND SIDE OF THE WORK LIMIT. 3. INITIAL SOIL STABILIZATION WITHIN THE WORK LIMIT SHALL BE ACCOMPLISHED BY APPLICATION OF MULCH AND/OR LOAM AND SEED WEATHER PERMITTING. 0 /0 20 40 L EGEND 0 CB DESIGN PERC RATE < 15 MIN/INCH -W- WA TER LINE O HYDRANT SOIL TEXTURAL CLASS - I1 GAS LINE 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER OVER HEAD WIRES V EFFLUENT LOADING RATE - 0.56 GPD/SF -E- AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER -T- UNDERGROUND TELEPHONE LINE 330 GPD / 0.56 GPD/SF - 590 S.F. REQUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- x-40.4 SPOT ELEVATION ..---40--•---_ EXISTING CONTOUR 40 STANDING 14-20 WHEEL LOADS. PROVIDED: 3-500 GAL LEACHING CHAMBERS W/4' STONE AROUND, A-614 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR 614 S.F. x 0.56 - 343 G.P.D. APPROVED EQUAL. SOIL TEST PI T DA TA & 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER INDICATES INDICATES PERCOLATION OBSERVED TESTED FOR LEVEL WHEN THERE lS MORE THAN ONE TEST GROUNDWATER OUTLET. TP +I rP 02 7. BEFORE CONSTRUCTION CALL -DIG-SAFE-. 0. HORIZON TEXTURE COLOR 10/.8 0" HORIZON TEXTURE COLOR 10118 1 -888 -DIC -SAFE AND THE LOCAL WATER DEPT. FILL A SANDY IOYR LOAM 2/2 FOR LOCATION OF UNDERGROUND UTILITIES. 5_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 101.4 15- _ - _ _ _ _ _ _ _ _ _ _ _ _ _ 100.6 A SANDY /ora B SANDY IOYR 6. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE LOAM 2/2 LOAM 4/6 !8' -- - - - - - - - - - - - -- 100.3 J2' - - - - - - - - - - - - - -- 99.1 DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION B GAMY 4/BR C I OF THE SYSTEM TO ALLOW FOR SCHEDUL 1 NG OF THE LOAM AND 5/4R 30' - - - - - - - - - - - - - - - 99.3 STONES CONSTRUCTION INSPECTIONS. C I SANDY IOYR FIRM IN LOAM AND 5/4 PLACE STONES 9. EXISTING CESSPOOL TO BE PUMPED DRY, REMOVED FIRM 1N AND BACKFILLED WITH SAND. PLACE /O. ALL UNSUITABLE MATERIAL !A A B HORIZONS, Cl) NO WATER NO WATER ENCOUNTERED BELOW THE INVERT OF THE LEACHING 12 91.8 IJ2. 90.8 FACI L 1 TY TO BE REMOVED FOR A DISTANCE OF 5' DATE: SEPTEMBER 19. 2013 TP .3 TP •4 AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE S. _HORIZON 0" TEXTURE COLOR /OI.S HORIZON TEXTURE COLOR O" /O 1.5 SANDY IDYR SANDY IOYR A '4 LOAM 212 LOAM 2/2 ll. NO DETERMINATION HAS BEEN MADE AS TO 15" --------------- 100.3 15 --------------- IOO.J COMPLIANCE WITH DEED RESTRICTIONS OR ZONING B SANDY IDYR B SANDY 10YR REGULATIONS. 1T SHALL REMAIN THE CLIENTS LOAM 4/6 LOAM 4/6 36' - - - - - - - - - - - - - -- 98.5 36' - - - - - - - - - - - - - -- 98.5 RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL Cl SANDY LOAM IOYA SANDY LOAM IOYR CI PERMITS. VARIANCES ETC. FOR THIS PROJECT. AND STONES 5/4 AND STONES 5/4 FIRM IN PLACE 93.5 FIRM IN PLACE 95.0 _ - - -96" RTI( SOUTH RTlj . _ , _ - ' - SOUTH 132 90C2 96 9SC2 SANDY LOAM IDYR SANDY LOAM IOYR� AND COBBLES 5/4 AND COBBLES 5/4 LOOSE f06' LOOSE N "vit 2 NO WATER 84.5 144' NO WA TER 89.5 x N3 k & _. L EGEND 0 CB CONCRETE BOUND -W- WA TER LINE O HYDRANT _G- GAS LINE - OHW- OVER HEAD WIRES V LIGHT POST -E- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEV/SION LINE x-40.4 SPOT ELEVATION ..---40--•---_ EXISTING CONTOUR 40 PROPOSED CONTOUR DATE: NOVEMBER 12. 2013 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: C 15 MIN/INCH S l TE PLAN OF LAND /0 RAILROAD AVENUE. MAP 112. PARCEL 34 YARMOUTHPOR T . MA. P R E P A R E D F O R: TODD P ERR Y 9 MOODY ROAD. HARW I CHPORT . MA 02646 SCALE: I 20' DECEMBER 9. 2013 STEPHEN A_ HAAS ENGINEERING, I N C Nlzmm 923 Route 6A In Yormouthport MA. 02675 / ( 508 ) 362-8132 JOB NO: 13-091