HomeMy WebLinkAboutDOA - 110 River St - Site Plan003SYSTEM PROFILE PROVIDE WATERTIGHT C.I. (NOT To SCALE) ACCESS COVERS TO FIN. GRADE 11.7, WMIL111\I 7WL nnVro n„rn nn,-...nr 4"4SCH40 PVC PIPES LEVEL 1ST 2' *9.7' 1 10. 1500 GAL H-20 14" EXIST. 2' TO 3' 8.68' TEE SEPTIC TANK TEE $ 43• CRAWLSPACE - GAS BAFFLE °O°O°°O0-_0 J 00000000000 00°00 0°000 4 UQ. LEVEL (ACME OR EOUAI 8.41' 8.24' JPO O° 0O000° 0O0 000000000000 0° O ° O ° 0Oo0°0 °00o°O0o„o O0 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) G61_8% SLOPE) (-L% % SLOPE) FOUNDATION- 15' - SEPTIC TANK 2' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM VARIANCES REQUESTED UNDER TITLE 5 15.405 AND TOWN OF YARMOUTH HEALTH REGULATIONS: 15.405 1(a): REDUCTION IN SETBACK, SAS & ST TO LOT LINE (10' TO 5'); 1(b): REDUCTION IN SETBACK, SAS TO FNDN. (20' TO 14') TOWN OF YARMOUTH: REG. 3.7: REDUCTION IN SETBACK, SAS TO WETLAND (MHW): 100' TO 52' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO 3" OF FINISH GRADE 29 SLOPE REQUIRED OVER SYSTEM / WITHIN 1I 11-9 .I. .I. J. (-!-% SLOPE) - 4' - TCCT �JP'11 � 1`!'1rC / f 11- t.s � � w.,r L. a._ v r.wy BENCHMARK TOP BRICK STEP I ENGINEER: ARNE H. OJALA, PE, SE EL = 11.8' WITNESS: AMY VON HONE, RS DATE: 6/8/11 / PERC. RATE _ < 2 MIN/INCH PROP. 2'x EXPANSION2D CLASS I SOILS / ELEV. 4,V SO 0.. 41 11-1' (/) /11.43 aa A / �. LS / 12" 1OYR 4/2 / .12' E 2 11.48x11. _ MS / 16 1OYR 5/1 2nd HOLE WAIVED 3�J B (SITE CONSTRAINTS) N11./ 20 LS p/ tOYR 5/6 '" 11.21 24" 9.1' ! 11.35 .22 C 49 1 ®.35 PERC MS ®.33 EXISTING BASINS 2.5Y 6/6 120" FOBS. WATER 1.1' 89-0'70 Scale:1 "= 20' 0 10 20 30 40 50 FEET (11) H-20 HIGH CAPACITY INFILTRATORS (NO STONE PROPOSED) 5.0' LEACHING FACILITY USE G -W AT EL. 2.3' (TIDALLY INFLUENCED) 12.20 <12. o / / • 11.76 c / �12. so 12.Ox / \f \j1 PAVED S' / DRIVE '�•1 C. 11 6 . 11.53 WA _ ETER PIT is 62 1.31'V �,.as � INV OUT EL -9.Y EXISTING DWELLING .58 TOP MON. EL - 11.6' LOT 8 7,726 SFt NOTES 1. DATUM IS NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10 CONTRACTOR SHALL BE RESPONSIBLE FOR IGSAFE CA LUNG AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. NOT TO SCALE aln Si 'fen oWo 0 PROPOSED LEACHING FACILITY. 016 y �{ c o� � leo 4 V 13 EL. 13 AS SHOWN ON COMMUNITY AND REMOVED OR PUMPED AND FILLED WITH SAND. CLEAN PANEL#250015 0006D DATED 7/2/92 SYSTEM DESIGN: LoCU v � o i N � EXISTING BUILDING COVERAGE: 15.8% DESIGN FLOW. 2 BEDROOMS ® 110 GPD = 220 GPD o T � � A 4 O A Nantucket a USE A 1500 GAL. H-10 SEPTIC TANK Sound . LEACHING: 4.73 SFAF x 6.25' LENGTH = 29.56 SF PER IGSAFE CA LUNG AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. NOT TO SCALE 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE ASSESSORS MAP 43 PARCEL 45 PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE "B" (HOUSE) & 12. EXISTING LEACHING FACILITY SHALL BE PUMPED V 13 EL. 13 AS SHOWN ON COMMUNITY AND REMOVED OR PUMPED AND FILLED WITH SAND. CLEAN PANEL#250015 0006D DATED 7/2/92 SYSTEM DESIGN: '.'`NOTE: ENTIRE SITE UES WITHIN INNER RIPARIAN ZONE GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING EXISTING BUILDING COVERAGE: 15.8% DESIGN FLOW. 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW** A-PRVIDE b 'FOR ROOF -RUN-OFF SEPTIC TANK: 220 GPD (2) = 440 USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: 4.73 SFAF x 6.25' LENGTH = 29.56 SF PER 5.70 HIGH CAPACITY INFILTRATOR UNIT vv. W -1R220 �14�tQT PD/0.74 GPD/SF = 297.3 SF LEACHING 6.19 ��1 EQ'D 297.3 SF/29.56 SF/UNIT = 10.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (11) H-20 HIGH CAPACITY UNITS IN FIELD -MHW AT BULKHEAD CONFIGURATION OF 1 ROW OF 6 UNITS & ELEV. 2.3' NGVD 1 ROW OF 5 UNITS AS SHOWN /11.60 / 11 UNITS x 29.5 SF = 325 SF > 297.3 SF PROP. 4'x8' CANTILEVERED DECK 325 SF (0.74) = 240 GPD (OK) >< t 0. (OVER EXISTING DECK) / **2 BR DEED RESTRICTION REQUIRED / % I 0.9C J J lJ n nn /(I 11.31 '9.^�4 r pN PROP. SECOND STORY VWTHIN FOOTPRINT t ..aa� a/o 0,18 6.29 'z'/8 (BEDROOM COUNT REMAINS AT 2) 1 0 lZL 0.0. •0\ 6.27 EXIST. PLATFORM, RAMP &FLOAT (LIC. X2611) BASS RIVER PROVIDE 5' WIDE MITIGATION PLANTINGS / OF NATIVE SPECIES (OR STONE) IN / CONSULTATION WITH CONSERVATION AGENT LANDWARD E\ WOOD OD BULKHEAD 0S?.1H Or MASS q� er PROVIDE APPROX. 35' OF 40 MIL LINER AT 5' OFF SAS /�° DANIEL DANisL_A. IN AREA SHOWN. T,)P AT EL 8.6'. BOTTOM AT EL. 4.6' o A. OJAI.A OJALA CI4'::_ vt .� No. 40980 fA� No.. 51) _Zp- 11 DATE DANIEL A. OJALA, P.E., P.L.S. APPROVED DATE BOARD OF HEALTH MA TITLE 5 SITE _PLAN OF 110 RIVER STREET SOUTH YARMOUTH PREPARED FOR DAVID McCARTHY JULY 20, 2011 off 508-362-4541 fax 508-362-9880 downcope.com down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 f -(2(A Co V'l