Loading...
HomeMy WebLinkAboutDOA - 10 Whale Rd - Site Plan002SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 5 BEDROOMS ® 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD (2) = 1100 USE AN H-10 2500 ST/PC COMBINATION (SEE DETAIL) LEACHING: BOTTOM AREA ONLY: 748 SF X (.74) = 553.5 GPD USE A 748 SF LEACHING FIELD AS SHOWN APPROVED NOTES MA DATE BOARD OF HEALTH I. UM,Vni ,J - 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7, THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8, PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING SEPTIC SYSTEM SHALL BE PUMPED AND REMOVED. 13. ALL RUN-OFF TO BE CONTAINED ON-SITE DESIGN REQUIRED (BY OTHERS). FINAL GRADING TO BE IN ACCORDANCE WITH FEMA REGULATIONS. 14. DRYWELLS (OR DRIP TRENCHES) SHALL BE INSTALLED TO CONTAIN ROOF RUN-OFF. 15. CONTRACTOR TO COORDINATE ALL UTILITY DISCONNECTS AND NEW SERVICES WITH APPROPRIATE VENDORS. 16. SHOULD PRIMARY LEACHING FACILITY FAIL, IT SHALL BE REMOVED IN ITS ENTIRETY, ALL CONTAMINATED SOILS REMOVED AND SYSTEM TO BE REPLACED IN KIND. B LS B LS 50" 1OYR 5/6 2.6' 66" 1OYR 5/6 C1 C1 PERC MCS MCS BOTT. AT 1 OYR 6/6 1 OYR 6/6 60" 60" V EL. 1.8' 114" DCE #10-006 -2.2' *THE INSTALLER SHALL VERIFY THE SEPTIC' SYSTEM PROFILE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND (NTS) ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM PROVIDE MIN. 20" DIAM. WATERTIGHT FIRST FLOOR BLDG ELEV, 12.0' CONCRETE ACCESS COVERS TO WITHIN 6. OF FIN. GRADE RAWLSPACE SLAB .6' TOP FOUNDATION 11.0' WITHIN 20' OF SAS 9.3' MIN. 75' OF COVER 0 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. MARK CORNERS OF LEACH FIELD WITH 24" #5 REBAR WITH SAFETY CAP DRIVEN JUST BELOW GRADE EACH CORNER OF LEACH FIELD. 4" DIA PERF. INSP. PORT TO SAND AT BOTTOM OF LEACHING FIELD. 4" THREADED CAP TO WITHIN 3" OF FINISH GRADE 40 MIL LINER FROM E4EV. 8.8' TO ELEV. 4.8' MIN. RETAINING WALL SCHEMATIC SHOWN, EXACT FASCADE \ AND CONSTRUCTION B OTHERS. TOP OF WALL HT. AS NOTED OVER P /r1I0 TOP PIPE 8.6' FINISHED GRADE- \4" LOAM & SEED 2% MIN SLOPE OVER SYSTEM REMAINDER OF CRAWLSPACERECAST SLAB AT EL 7 4' PRECAST H-10 FLOOD VENTS WITHIN 12" GRADE 4' CH4o (GROUND AT EL. 7.4) REQ. +- VENTS ON 2 SIDES REQ. "' "" +A 7 2' FLOOD VENT/FOUNDATION DESIGN " BY OTHERS. f s. ;w 7.5'* ry,0 BUOYANCY CALCS: 2500 H-10 TANK WGT: 22560 LBS 0.6' x 11.8' x 6.3 x 62.4 = 2753 UP (OK) V EL. 1.8' TEST HOLE LOGS 10* TEE 2500 GAL H-10 LOCUS IS WITHIN FEMA FLOOD ZONE ! �\ PANEL #250015 0005D DATED 7/2/1992 ENGINEER: ARNE H. OJALA PE, PLS SE1804 COMBINATION ZONING DISTRICT: R25 RESIDENTIAL WITNESS: PHIL RENAUD SHOREY OR EQUAL o0 .00T -VENT (SEE DETAIL) \ DATE: 2/10/2010 4 ER O A D PVC. S=0.005 a MIN. SIDE SETBACK 15' \ MIN. REAR SETBACK 20' PERC. RATE _ < 2 MIN/INCH MAX. LOT COVERAGE 25% 22.0% SITE IS LOCATED NOT WITHIN MASS CLASS I SOILS ZONE II. O ELEV. 4 2 Q ELEV. 0„ 6_8' 011 7.3' 0, •�• 7LL 6"DEPTH MIN BELOW INV. FILL28"4.5' o eaeeceue'oo'oo ga 36" 4.3' 8.00' A LS 4 o PROPOSED ROCK WALL VENEER A LS 8.25 32" 1OYR 2/1 4,1' 38" 1OYR 2/1 1 4.1' E FS 8.52' E FS 36" 1OYR 6/1 3.8' 40" 1OYR 6/1 4.0' B LS B LS 50" 1OYR 5/6 2.6' 66" 1OYR 5/6 C1 C1 PERC MCS MCS BOTT. AT 1 OYR 6/6 1 OYR 6/6 60" 60" V EL. 1.8' 114" DCE #10-006 -2.2' *THE INSTALLER SHALL VERIFY THE SEPTIC' SYSTEM PROFILE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND (NTS) ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM PROVIDE MIN. 20" DIAM. WATERTIGHT FIRST FLOOR BLDG ELEV, 12.0' CONCRETE ACCESS COVERS TO WITHIN 6. OF FIN. GRADE RAWLSPACE SLAB .6' TOP FOUNDATION 11.0' WITHIN 20' OF SAS 9.3' MIN. 75' OF COVER 0 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. MARK CORNERS OF LEACH FIELD WITH 24" #5 REBAR WITH SAFETY CAP DRIVEN JUST BELOW GRADE EACH CORNER OF LEACH FIELD. 4" DIA PERF. INSP. PORT TO SAND AT BOTTOM OF LEACHING FIELD. 4" THREADED CAP TO WITHIN 3" OF FINISH GRADE 40 MIL LINER FROM E4EV. 8.8' TO ELEV. 4.8' MIN. RETAINING WALL SCHEMATIC SHOWN, EXACT FASCADE \ AND CONSTRUCTION B OTHERS. TOP OF WALL HT. AS NOTED OVER P /r1I0 TOP PIPE 8.6' FINISHED GRADE- \4" LOAM & SEED 2% MIN SLOPE OVER SYSTEM REMAINDER OF CRAWLSPACERECAST SLAB AT EL 7 4' PRECAST H-10 FLOOD VENTS WITHIN 12" GRADE 4' CH4o (GROUND AT EL. 7.4) REQ. +- VENTS ON 2 SIDES REQ. "' "" +A 7 2' FLOOD VENT/FOUNDATION DESIGN " BY OTHERS. f s. ;w 7.5'* ry,0 BUOYANCY CALCS: 2500 H-10 TANK WGT: 22560 LBS 0.6' x 11.8' x 6.3 x 62.4 = 2753 UP (OK) V EL. 1.8' RISERS (TYP.) 2'0 PROP TEE 4"0SCH40 PVC �� R.75�CAP 10* TEE 2500 GAL H-10 LOCUS IS WITHIN FEMA FLOOD ZONE ! �\ PANEL #250015 0005D DATED 7/2/1992 SEPTIC TANK/PC PIPES LEVEL 1ST 2' ZONING SUMMARY COMBINATION ZONING DISTRICT: R25 RESIDENTIAL \� SHOREY OR EQUAL o0 .00T -VENT (SEE DETAIL) \ c: RISERS (TYP.) 2'0 PROP TEE 4"0SCH40 PVC �� R.75�CAP CLEAN FILL LOCUS IS WITHIN FEMA FLOOD ZONE ! �\ PANEL #250015 0005D DATED 7/2/1992 TOP RET. WALL ELEV. 8.8' PIPES LEVEL 1ST 2' ZONING SUMMARY pur ZONING DISTRICT: R25 RESIDENTIAL \� ENDS`'.>�a' o0 .00T -VENT / EXS?7^rc r \ \ O 4 ER O A D PVC. S=0.005 a MIN. SIDE SETBACK 15' \ MIN. REAR SETBACK 20' 29.7' MAX. LOT COVERAGE 25% 22.0% SITE IS LOCATED NOT WITHIN MASS .. ZONE II. O -k J 3/4"-1-1/2" DOUBLE WASHED STONE LEACHING FIELD 0, •�• 1, / 6"DEPTH MIN BELOW INV. 1 �' i. o eaeeceue'oo'oo ga 8.00' l 4 o PROPOSED ROCK WALL VENEER e"OOOOOOOOOOO °o "8.35 8.25 LEVEL BOTTOM O 8.52' i, i� 1 i % i, 55' 5' MIN UNSUITABLE O O O O O O O O O O O C DBLOCK UP FOR 24 COVER TYP. 7.50 SOIL REMOVAL O OO OO OO OO OO OO OO OO OO OOOOC -BOX ACME DB -9 OR EQ. WHERE SPECIFIED Ono OOnOnOOOOOOO n n n n n n n n r DEPTH _p f e; PER SOIL LOGS ,.'.1•."' 5.0' uQeoepeoeouoeoeac e e e 6 CRUSHED STONE OR MECHANICAL WATER TEST D'BOX FOR LEVELNESS e'e"er COMPACTION. (15.221 [21) USE TIDALLY INFLUENCED ADJ. GROUNDWATER ELEV. 2.5' LEACHING: USE A 748 SF LEACHING FIELD 748 SF X .74 = 553 GPD O.K. (-L+-% SLOPE) ACCMAINTENANCE FOUNDATION 10' ST/PC 40' D' BOX LEACHING MUSTSBEFOR PROVIDEDNFOR ZABEL FILTER. FACILITY INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 7.2' SEPARATE CIRCUIT FROM PUMP ZABEL FILTER FLOAT SWATCH ALARM ON (Ai00) 24' TEE SETTINGS: OUTLET TEE W/EXTENSION PUMP ON 1500 GAL. NI . 5" WORKING RANGE 6" OFIS11MAS 5" 6.5' PUMP OFF 12 4 DOSES PER DAY, AT 110 GAL. PER 000000 00 00 0 DOSE (5" WORKING RANGE) _ 6\\ 2500 GAL. SEPTIC TANK/PUMF \ EXISTiNG \ (NOT TO SCALE) - i /1dEiE. BENCHMARK: USE C. BASIN I AT ELEV. 5.2' \\ \ �a ✓WELLI.NG �. TC "WID4N. = Ross' =? 9\ ° .0 8 . t n 6� I \\ J h \ 1 SOF D-1 CI 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE s WITH CLEAN MED. SAND, TO MEET _ SPECIFICATIONS OF 310 CMR 15.255(3) � O \ �� \ \ \ PROP. RETAINING WALL T.O.W. = EL ! ; 8.8' (SEE DETAIL, DESIGN BY OTHERS) D-2 D-3 � \ / / DATE DANIEL A. OJALA, P.L.S. / � I .eOSTS/ NOTE: 550± GAL. RESERVE PROVIDED IN PC WEEP HOLE CHECK VALVE MYERS SRM 4 SUBMERSIBLE 4/1 HP PUMP `e" BAFFLE CHAMBER COMBINATION LOCUS MAP SCALE 1"=2000'± FLOOD VENT 6 \ \ LOCUS IS WITHIN FEMA FLOOD ZONE / \ \ \ PANEL #250015 0005D DATED 7/2/1992 DATUM: NGVD \(TYP.) �7- T' ZONING SUMMARY ZONING DISTRICT: R25 RESIDENTIAL \� 1Z@Ci. o0 .00T -VENT / EXS?7^rc r \ \ O (T•P,� GARAGE \ MIN. SIDE SETBACK 15' \ MIN. REAR SETBACK 20' 29.7' MAX. LOT COVERAGE 25% 22.0% SITE IS LOCATED NOT WITHIN MASS DEP ZONE II. OWNER OF RECORD -k J •�• 1, / N£\10 � s .`V / / ,/ / \ - i /1dEiE. BENCHMARK: USE C. BASIN I AT ELEV. 5.2' \\ \ �a ✓WELLI.NG �. TC "WID4N. = Ross' =? 9\ ° .0 8 . t n 6� I \\ J h \ 1 SOF D-1 CI 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE s WITH CLEAN MED. SAND, TO MEET _ SPECIFICATIONS OF 310 CMR 15.255(3) � O \ �� \ \ \ PROP. RETAINING WALL T.O.W. = EL ! ; 8.8' (SEE DETAIL, DESIGN BY OTHERS) D-2 D-3 � \ / / DATE DANIEL A. OJALA, P.L.S. / � I .eOSTS/ NOTE: 550± GAL. RESERVE PROVIDED IN PC WEEP HOLE CHECK VALVE MYERS SRM 4 SUBMERSIBLE 4/1 HP PUMP `e" BAFFLE CHAMBER COMBINATION LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 14 PARCEL 128 LOCUS IS WITHIN FEMA FLOOD ZONE Al2 (EL 10) AND B AS SHOWN ON COMMUNITY PANEL #250015 0005D DATED 7/2/1992 DATUM: NGVD ZONING SUMMARY ZONING DISTRICT: R25 RESIDENTIAL DISTRICT 1Z@Ci. '�2oV\l�D MIN. LOT SIZE 25,000 S.F. 15,600 S.F, MIN. LOT FRONTAGE 150' 130' MIN. FRONT SETBACK 30' 31.3' MIN. SIDE SETBACK 15' 15.9' MIN. REAR SETBACK 20' 29.7' MAX. LOT COVERAGE 25% 22.0% SITE IS LOCATED NOT WITHIN MASS DEP ZONE II. OWNER OF RECORD THEODORE WOJNAR 104 CALM COURT BELLAIRE, TX 77401 REFERENCES LAND COURT DOC: 1,045,034 LAND COURT CTF; 181185 LAND COURT PLAN 14426-H (SHEET 2) REQUIRED INSPECTIONS AND CERTIFICATIONS 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS COMPLETE. 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POURING OF WALL 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY DEPOSITED 5. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AND PUMP MECHANISMS AFTER INSTALLATION ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT THE RETAINING WALL, SEPTIC SYSTEM AND PUMP MECHANISMS HAVE BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED PLAN. TITLE 5 SITE PLA OF 10 WHALE ROAD WEST YARMOUTH PREPARED FOR THEODORE WOJNAR DATE: MARCH 15, 2010 REV 4/20/10 (MOVE/ROTATE HSE) REV 5/25/10 (ROOF & PATIO) Scale:1 "= 20' 0 10 20 30 40 50 FEET I off 508-362-4541 fax 508-362-9880 downcope.com down cope engineering, idc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 10-006 WOJNAR.DWG