HomeMy WebLinkAboutEngineered Plans - 2016LEGEND N x 100.98 EXISTING SPOT GRADE ® Food St — ---- — EXISTING CONTOUR rL� Forest Rd �e U OVERHEAD WIRES Q0 M°n st —p, H. W.— OVERHEAD WIRES od M rn'n9 Dr 51,46 20 W W EXISTING WATER SERVICE LOCUS pr `A S G EXISTING GAS SERVICE r MOrnin 1 .99 82 32 Dr Mo in o TEST PIT �, o FENCE LINE ( TYP.) 0� �} BENCHMARK May Ln N 13 �n \ Elm Sunset Dr x 100,61 h� 10054 LOT 22 x 11,890 ftF PARCEL ID: �42�80 � GENERAL NOTES: mit valid for REPAIR OF SEPTIC SYSTEM � � 1 �-- 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL P � BOARD OF HEALTH AND THE DESIGN ENGINEER. B LY, due to State and Loral septic variances. ird of Health re%iew and approval is required for ' I 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS I OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE a st future addoionsheno%ations/aIterations to v age facilities and/or structures/d�tielling. I\ "".94 PROVIDE A NEW LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: I —310 CMR 15.405(1)(a): Yarmouth Health t)cp[artmer�t�y� I 101.04 DECK �` I SEWER OUTLET INV.. =99,80 1 A 3' variance S.A.S. to property line front for a 7' setback ) P P Y (front), APPROVE �� ! ` 100,71 shr. x (INSTALL CLEANOUT) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR f � x ` TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING 4t�/ e Date /EXISTING N W o? 1 FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. v/ HOUSE&14) 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF o T.O.F.= 102.41 m THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF M O � HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE FA 8. THERE ARE NO ABUTTING WELLS WITHIN 100' OF THE PROPOSED S.A.S. PORCH BM 99.90 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS GARAGE 102,04 — AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE 101.44 00 5 DIRECTED BY THE APPROVING AUTHORITIES. / — SLEEVED SEWER FOR 10' EACH SIDE OF WATER SERVICE CROSSING 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY BENOUTSICHMARK 101E22 101.40 �JA�K ,58 Z THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING ReoTT. STEP BRICK ,,C�.� PROPOSED SEPTIC TANK CONSTRUCTION. EL. =102.04 T ., cfl G-)1 " S� 1. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND PACED` �1p O C REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). EXISTING SEPTIC TANK "CT r e "DRIVEWAY. ` �_ —_ -I 100,22 Of Mqs F��� s9� 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. TO BE PUMPED, RUPTURED, FILLED (-1 J�ED IAI / PETER T. McENTEE 13, THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. WITH SAND AND ABANDONED INSpQR IO L _ I CA �i 01�E P o 00 CIVIL 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC �L..J 10' No. 35109 SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. 100,32 ., .:` .,` .:100,19": c0 100,40 3 x 100 2 77. x� GISiE��� P0F PROPOSED SEPTIC SYSTEM UPGRADE PLAN N 57°18.05 E UP C;.,..,..', :: `;•. ' ' 0,00 x 100,30 1 E� ;..,.:. r P ` 6 14 ELM LANE, SOUTH YARMOUTH, MA 100,34 e e o W povemen W W 00.35 t6� 1 `t Prepared for: Larry Keefner, 14 Elm Lane, So. Yarmouth, MA 02664 PK SET OWNER OF RECORD ELM LANE EXISTING LEACH PITS 100.00411 KEEFNER, LAWRENCE W JR Engineering by: SCALE DRAWN JOB. N0. "=30' TO BE REMOVED KEEFNER, PATRIICA 1 P.T.M. 211-16 Engineering Works, Inc. HOUSE LOCATION TAKEN FROM CERTIFIED PLOT PLAN BY 14 ELM LANE 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. BARNSTABLE SURVEY CONSULTANTS, INC., DATED 4/24/73 SO. YARMOUTH, MA 02664 (508) 477-5313 10/4/16 P.T.M. 1 Of 2 h SEPTIC TANK INSTALL RISERS & COVERS OVER INLET AND SET TO 6" OF FINISH GRADE. F.G. EL.=101.0± 48" LIQUID LEVEL ADD I GAS BAFFLE IPROVIDE NEW SEWER OUTLET AT HOUSE AT, OR ABOVE, INV.=99.80 PROPOSED D -BOX INSTALL WATERTIGHT RISER & COVER SET TO 6" OF GRADE L = 10' @S=1% (MIN.) 4'SCH40 PVC F.G. EL.=100.5± L = 8' ® S=1% (MIN.) 4'SCH40 PVC ' 7.13" TO JINVERT INV.=98.35 PROPOSED INV.=98.18 FILL INV.=98.45 D -BOX 99.6 INV.=98.10 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED 6" STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) CONTRACTOR SHALL INSTALL A GAS BAFFLE ON THE OUTLET TEE. DESIGN CRITERIA NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL.98.6 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL 2 INSPECTION PORTS(MIN.) AT END OF S.A.S. BREAKOUT=TOP TOP ELEV. =98.58 INV. ELEV.=98.10 BOTTOM ELEV.=97.50 - 4' MIN. OF NATURALLY OCCURRING PERVIOUS MATERIALS 5' MIN. ABOVE HIGH GROUNDWATER BOTTOM OF TEST HOLE, EL.=92.5 F.G. EL.=100.3 to 101.1± MAINTAIN 2% GRADE (MIN.) OVER S.A.S. INSPECTION PORT TWO (MIN.) 5 ROWS OF 6 UNITS AT 5.0'/UNIT = 30.0' ESTABLISH VEGETATIVE COVER BACKFILL WITH CLEAN NATIVE OR PERC SAND TO TOP OF CHAMBERS L:1.8-37- EFFECTIVE WIDTH=11.5' (LEAVE 1" BETWEEN ROWS) EXISTING SUITABLE MATERIAL USE 5 ROWS OF 6-ADS'Arc 36 HD UNITS IN A STONELESS CONFIGURATION WITH BED DIMENSIONS OF 14.2' x 30.0' SEPTIC SYSTEM PROFILE TYPICAL SECTION NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO-S.A.S. NOT DESIGNED FOR GARBAGE GRINDER LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY PROPOSED D -BOX: 1 INLET, 5 OUTLET (MINIMUM), H-10 RATED USE 5 ROWS OF 6-ADS_Arc- 36HC HD UNITS IN A STONELESS CONFIGURATION WITH BED DIMENSIONS OF 14.2' x 30.0' BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF UNIT) (Arc36 Units) 30 UNITS x 5.0 LF x 4.80 SF/LF = 720.0 SF DESIGN FLOW PROVIDED: 0.74 GPD/SF(720.0 SF) = 532.8 GPD NOMINAL AREA OF BED = 14.2' x 30.0' = 423.0 SF -v-. \ C4 LA �s. J I� N OPOSED S. SEPTIC LAYOUT SOIL LOG DATE: SEPTEMBER 21, 2016 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: AMY VON HONE R.S. HEALTH AGENT ELEV. TP DEPTH 100.4 ll 0 FILL 99.6 10" AE LOAMY SAND 98.9 1 OYR 4/2 18" B LOAMY SAND PERC 14"/32 97.7 1OYR 5 8 32" C1 MED. SAND 2.5Y 6/6 92.5 1 ADJ. G.W. - 91.2 STG. G.W. 110" 90.4 120" STANDING G.W. AT EL.=91.2, INDEX WELL MIW-129, ZONE A WATER LEVEL=9.6 (AUGUST2016), ADJUSTMENT=2.6' USE 1/2 ADJUSTMENT PER B.O.H.=1.3''ESTIMATED HIGH G.W., EL.=92.5 PERC RATE 2 MIN/IN. ("B/C" HORIZONS) 13" 32 END CAP END CAP FRONT VIEW SIDE VIEW END CAP REAR/TOP VIEW NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. 4640 TRUEMAN BLVD HILLIARD, OHIO 43026 Arc 36 DETAIL e ADVANCED DRAINAGE SYSTEMS. INC. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 14 ELM LANE, SOUTH YARMOUTH, MA Prepared for: Larry Keefner, 14 Elm Lane, So. Yarmouth, MA 02664 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. NTS P.T.M. 211-16 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET N0. (508) 477-5313 10/4/16 P.T.M. 2 of 2