HomeMy WebLinkAboutEngineered Plan - 2016N KEY: EXISTING CONTOUR: - - - - A. PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 �<v Svc PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: ' UTILITY POLE: M�n9 R� FENCE LINE: - HYDRANT: O`ST LOCUS RETAINING WALL: LOCATION MAP LOT 11 (9,180 SF) ASSESSORS MAP: 22 PARCEL: 169 PLAN BOOK: 108, PAGE: 141 BENCHMARK AT--- LEFT CORNER OF BOTTOM CONC. STEP ELEVATION = 105.86 M16-41 104 o� RrO�� 103 / 104 I' foQ/2��O,QoG, cp as oe 101.8 1 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 4 BEDROOMS AT 110 GAL / DAY = 440 GAL / DAY SEPTIC TANK: 440 GAL / DAY x 2 DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK r LEACHING AREA: USE 3 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (33.5'x 12.8'x 2' DEEP) SIDE AREA: (33.5' + 12.8') x 2 x 2 = 185 SF (0.74) =L37 GAUDAY BOTTOM AREA: 33.5' x 12.8' = 429 SF (0.74) =317 GAUDAY CAPACITY = 454 GAUDAY a9 Q� �o �A aye a'eo Q r 105 A', CAtiC' 6if �S \ f 104 i 7 X103 X01.6 7,102 th-1 i a� a SEPTIC SYSTEM SECTION COVERS WITHIN OF FINISHED GR 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR OF COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN bed bed room room bath 2nd floor living bed room room -_ bed kitchen [bath ro m 1stfloor gbh EXISTING FLOOR PLAN I Yarmouth Health Department 414PPR VES I ane Date MAX. COVER ju (1' MIN) 99.92 99.75 - ELEV. ELEV. D -BOX (6" STONE UNDER) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 8-16-16 PERCOLATION RATE: < 2 MIN/IN PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" WASHED STONE INSPECTION PORT i-- ELEV.= 100.08 1,19 ° ° i'II 97.25 H H ELEV. 33.5'x 12.8' 3 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (33.5'x 12.8'x 2' DEEP) TH-1 102.0 106.73 ELEV. TOP OF 91, ° FOUNDATION 101.3 _V4 B HORIZON 104.1 ELEV. ° ° 10YR 5/8 100.25 ELEV. ' a COVERS WITHIN OF FINISHED GR 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR OF COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN bed bed room room bath 2nd floor living bed room room -_ bed kitchen [bath ro m 1stfloor gbh EXISTING FLOOR PLAN I Yarmouth Health Department 414PPR VES I ane Date MAX. COVER ju (1' MIN) 99.92 99.75 - ELEV. ELEV. D -BOX (6" STONE UNDER) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 8-16-16 PERCOLATION RATE: < 2 MIN/IN PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" WASHED STONE INSPECTION PORT i-- ELEV.= 100.08 1,19 ° ° i'II 97.25 H H ELEV. 33.5'x 12.8' 3 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (33.5'x 12.8'x 2' DEEP) TH-1 102.0 O/A HORIZON ELEV. LOAMY SAND 91, 10YR 3/1 101.3 B HORIZON LOAMY SAND 30" 10YR 5/8 99.5 C HORIZON MEDIUM SAND 2.5Y 7/4 138"1 1 90.5 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. - - - 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. II NAAMYYVV V t r4 THOMAS J. McLE �-LAN, P.E. SITE PLAN LOCATION: \ 9 RAINBOW RD., W. YARMOUTH, MA PREPARED FOR: GORDAN ROBERTSON CE: 8-16-16 SCALE: 1" = 20' BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048