HomeMy WebLinkAboutEngineered Plan - 2016OPTIONAL SWALE
6 AN OPTIONAL SWALE IS SHOWN 2.5' OFF THE FOUNDATION EXISTING FLOOR PLAN
a TO DEFLECT RAIN WATER RUNOFF. THIS WILL IMPACT EXISTING
BUSHES. IF SWALE IS BUILT 5' OR 6' OFF FOUNDATION. NOT TO SCALE
T_ THEN BREAKOUT IS NOT MET, AND A 2.5' DEEP IMPERVIOUS
m BARRIER IS NEEDED --5' OFF LEACHING WITH TOP AT 99 =
DEN/BD
BDRM ¢
In RM KIT. DEN GARAGE
.J
J CTno A r_C
x 11.46 11,61 12.1
\
x 11.37 \ x 11.8
� X11.5 5173-1 1
\
\ ) 11.20 STONE
\ \ x 10,97 / 11,Qp5��_
1.01
n10, 6 4
x 10,40 \
MAXIMUM FEASIBLE COMPLIANCE APPROVALS_ REQUESTED:
1. VARY LEACH AREA TO PROPERTY LINE BY UP TO 5'
VARY TANKS TO PROPERTY LINE BY UP TO 4'.
310 CMR 15.211 (1).
2. VARY SEPARATION TO HIGH GROUNDWATER BY 1' .
310 CMR 15.212.
3. NO RESERVE AREA COULD BE PROVIDED. 310 CMR 15.248.
BDRM ILVRM
OLD TANK NOT DEEMED
USABLE BY INSPECTOR
�1?.9 CRUSH IN PLACE
'OP NW CORNER CONSTRUCTION NOTES
9.65 NAVD88
1. WASHING MACHINE AND KITCHEN DO NOT APPEAR TO BE
TIED INTO SEPTIC TANK. DO FLOW TEST TO VERIFY.
N/F 2. HAVE PLUMBER TIE IN WASHER & SINK, AS SHOWN.
GLADYSHEVA 3. IF SWALE DONE KEEP CLOSE TO FOUNDATION, OTHERWISE
AN IMPERVIUOS BARRIER WILL BE NEEDED.
N /F
SOSTEK
BUOYANCY CALC'S-MONOLITHIC 1500 GAL. SEPTIC TANK
LEGEND
T 1
TEST HOLE LOCATION, NUMBER
W
WATER LINE MARKINGS
E
OVERHEAD ELECTRIC WIRES (IF SHOWN)
G--
GAS LINE MARKINGS
x 9.5 X 9.9
EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT)
6-�-
EXISTING CONTOUR
g-
PROPOSED CONTOUR
0
UTILITY POLE (IF SHOWN)
®
EXISTING DRAINAGE CATCH BASIN
x
FENCE (IF SHOWN, NOT ALL SHOWN)
0
TREE (IF SHOWN, NOT ALL SHOWN)
REV. 9/30/16--19
ARC 36LP CHAMBERS
BDRM ILVRM
OLD TANK NOT DEEMED
USABLE BY INSPECTOR
�1?.9 CRUSH IN PLACE
'OP NW CORNER CONSTRUCTION NOTES
9.65 NAVD88
1. WASHING MACHINE AND KITCHEN DO NOT APPEAR TO BE
TIED INTO SEPTIC TANK. DO FLOW TEST TO VERIFY.
N/F 2. HAVE PLUMBER TIE IN WASHER & SINK, AS SHOWN.
GLADYSHEVA 3. IF SWALE DONE KEEP CLOSE TO FOUNDATION, OTHERWISE
AN IMPERVIUOS BARRIER WILL BE NEEDED.
N /F
SOSTEK
BUOYANCY CALC'S-MONOLITHIC 1500 GAL. SEPTIC TANK
LEACH AREA, AND DISPOSE OF AS DIRECTED BY
JOB NO. Y16-19
14. ALL CONSTRUCTION TO
MEET TITLE 5 AND LOCAL REGULATIONS.
NOTES
Stergist.dwg
N
July 21, 2016
14"
FB 32/16 SB 14/14
'
1.
LOCUS IS A.M. 22, PARCEL 178.
WITNESSED BY:
2.
ELEVATIONS SHOWN ARE NAVD88 BASED UPON TOWN MONUMENT NO. 28 AND VERTCON.
.3.
HOUSE IS IN AE 11 FLOOD] ZONE, PROPOSED LEACHING IS IN FLOOD ZONE X(< 0.2% RISK)
FrQ
iz�
SOIL SURVEY(1993):
ON FIRM DATED JULY 16, 2014.
eta
4.
ALL PIPES TO BE 4" SCH X40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED)
Harwich outwash plain deposits
5.
MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER.
j
Invert 6.50±
6.
COMPONENTS TO BE AASH,TO H-10, UNLESS NOTED.
7.
INLET TEE TO PROJECT DgWN 13", OUTLET TEE DOWN 14".
8.
IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW
Invert 9.63
D -BOX EXIT PIPES TO BE (LEVEL FOR FIRST TWO FEET.
NOT TO
9.
DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED.
SCALE
COVERS: SECURE COVERS TO GRADE OVER PUMP AND FILTER/ OTHER COVERS WITHIN 6" OF GRADE.
LOCATION MAP
10.
STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP.
® Filter Cloth
11.
IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND,
CONTACT THE BOARD OF
HEALTH, OR R.J. CADILLAC.
Proposed
12.
IF AN OVERDIG IS CALLED; FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING
TEST HOLE 1
IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3).
13.
PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN
DEPTH (inches) ELEV.(feet)
HEALTH AGENT
LEACH AREA, AND DISPOSE OF AS DIRECTED BY
0
14. ALL CONSTRUCTION TO
MEET TITLE 5 AND LOCAL REGULATIONS.
TEST HOLE DATE:
July 21, 2016
14"
NO GRADE CHANGE IS PROPOSED PERFORMED BY:
Ron Cadillac, Soil Evaluator
UNLESS SWALE IS BUILT
WITNESSED BY:
Amy Von Hone, RS, CHO
i
PERC RATE:
<2'-00"/inch (B layer)9.99
„ a
SOIL SURVEY(1993):
Carver coarse sand 31
32"
Exist. Found.
Exist.
GEOLOGIC MAP(1986):
Harwich outwash plain deposits
Invert 6.94
Exist. Cast Iron
j
Invert 6.50±
19 --ADS ARC 36LP
�t To Grade Use Gas Baffle
LOW PROFILE CHAMBERS
Invert 6.90
H=10 Effluent Filter
Invert 9.63
Exist. C.I. 17"
AVg.COver�
Proposed Top Units=9.87
S=1 /8"/ft+
� - see detail
® Filter Cloth
Proposed
3" Max.
1500 Gal.
��nspection Port
Invert 6.75±
Monolithic
Tank
P
114"
Existingeptic
w
water roofin
----------_
S ;tar
3.811138"
WEIGHT OF EMPTY TANK AND AVERAGE 17" COVER
CHAMBER= 6.00 TON (PER ACME-SHOREY)
17" COVER= 1.42' X 5.67' X 10.83' X 0.055 TON/CU. FT.
17" COVER=4.80 TON
TOTAL= 6.00 TON + 4.80 TON = 10.80 TON
WEIGHT OF WATER --HIGH GROUNDWATER DOWN
(5.2 -2.17) X 5.67' X 10.83' X 0.0312 TON/CU. FT.
WEIGHT WATER= 5.81 TON
TANK AND 36" COVER ARE HEAVIER BY 5.0 TON.
BUOYANCY CALC'S-MONOLITHIC PUMP CHAMBER
WEIGHT OF EMPTY CHAMBER AND AVERAGE 36" COVER
CHAMBER= 4.60 TON (PER ACME-SHOREY)
36" COVER= 3' X 5.42' X 8.25' X 0.055 TON/CU. FT.
36" COVER=7.38 TON
TOTAL= 4.60 TON + 7.38 TON = 11.98 TON
WEIGHT OF WATER --HIGH GROUNDWATER DOWN
(5.2 -1.90) X 5.42' X 8.25' X 0.0312 TON/CU. FT.
WEIGHT WATER- 4 60 TMI
11.5
10.3
8.8
2.0
an y � 0.0
Invert 2.17 } Tee
Proposed Invert 9.80 Invert 9.52 of
6" Stone or compact Proposed Proposed I 4 Bottom
5' I l
� I � � ! 10 �
10, I 1' 140'1 i N f 2'� High Ground Water=5.2
' �p , 10, 3.2' USGS Adjustment
16
DESIGN DATA G Mashpee29--Zone B
BEDROOMS: 3 Observed Water=2.0
GARBAGE GRINDER: No LEACH AREA
REQUIRED CAPACITY: 330 GPD USE 19 ADS ARC 36LP CHAMBERS IN BED
EXISTING SEPTIC TANK: ! 1000 GAL. FORMATION, AS SHOWN, IN AND 8'-6" WIDE
EFFECTIVE LEACHING AREA: 449.35 SF BY 4(36 'LONG BY 3.8" DEEP LEACH AREA.
4.73 SF/LF X 5'/UNIT=3.65 S.F/UNIT 3S t�
19 UNITS X 23.65 SF/UNIT=449.35 SF(EFFECTIVE) 5' REMOVAL
DESIGN CAPACITY: 332.5 GPD DO 5' ALL AROUND AND UNDER REMOVAL
[(449.35 SF) X .74 GPD/SF] OF OLD LEACHING.
PUMP CHAMBER STORAGE CAPACITY: 330 GAL.
DOSES PER DAY: `Y 2.8
Y.
r � `
TANK AND 36" COVER ARE HEAVIER BY 7.4 TON. I
MONOLITHIC 1000 GALLON
H-10 PUMP CHAMBER
W/ WATERPROOFING
DRILL 3/8 WEEP/VENT HOLE Cover to Grade
"H=10
Recommend Floats 2" PVC
replaceable from top
Quick Disconnect/
6.48 larm 34" Union
Invert On 30" Check Valve
nff 95" -- --4.39 ------
6" STONE UNDER
MAKE FACTORY WATER -PROOF
i
I
ALARM & PUMP NOTES j
1. ALARM TO BE WIRED BY ELECTRICIAN ONj
SEPARATE CIRCUIT FROM PUMP. j
2. ELECTRICAL WORK TO BE INSPECTED BY
WIRING INSPECTOR. ,
3. ALARM TO BE LOCATED IN HOUSE.
4. PUMP TO BE CAPABLE OF PASSING
1-1/4" SOLIDS AND INSTALLED IN STRICT
CONFORMANCE WITH MANUFACTURER'S
SPECIFICATIONS.
5. USE MEYER SRM4, 4/10 HP PUMP, OR
EQUIVALENT.
6. TO PROVIDE FOR EASY AND SAFE i
MAINTENANCE OF PUMP:
-PROVIDE UNION/DISCONNECT IN 2" PVC
LINE AT TOP PUMP CHAMBER SO PUMP
CAN BE REMOVED FROM TOP OF TANK.
-RECOMMEND FLOATS BE ATTACHED TO 2"
PUMP LINE SO FLOATS CAN BE ADJUSTED
OUTSIDE CHAMBER.
THIS PLAN IS A VALID COPY ONLY IF IT BEARS
AN ORIGINAL RED STAMP AND SIGNATURE.
�(N
OF AM4ASq ASN OF A4480
RONALD yGN°� RONALD
o JAMES ' o JAMES
CADILLAC r" " CADILLAC "
# 1060 # 35779 r
�FESS\0
SANITAR\P� � 3o qtia SURs1�y
riv I+� `
HEALTH AGENT APPROVAL
DATE
Permit valid for REPAIR OF SEPI IC SYSTEM
ONLY;. due to State and 1 ural septic variances.
Board of I.Iealth review and approcat is required for
any future additions/renis <itiuns%alicrations to
sewage facilities.and/or structures/6%elling.
YarmouthAealth Department
APPROVEW �'�
'Name Date
SITE PLAN
FOR
STERGIS ESTATE
LOTS 9 & 109 30 FRANKLIN ST., W. YARMOUTH, MA
I
ISEPTEMBER 19, . 2016 SCALE: 1"=20'
RONALD J. CADILLAC, PLS, RS, P.C.
PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN
P.O. BOX 258
WEST YARMOUTH, MA 02673
(508) 775-9700
2016 BY R.J. CADILLAC
PAGE 1 OF 1