Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2016LEGEND II — Lsu,D u nw UUIN I UWrt X 99-1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 H-10 SEPTIC TANK LEACHING: TEST HOLE 2� SLOPE OF GROUND �Qo UTILITY POLE TOTAL: FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING SYSTEM DESIGN: TOP FOUND. EL. 16.0' PRECAST H-10 RISERS (TYP.) .: 2'b 4•' .. :; PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE MINIMUM _75' OF Cr)VFR r1VFR PRFCAC SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE i ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 115.19 WATER TEST WBOX FOR LEVELNESS BLOCKS OR PRECAST H-10 MORTAR ALL PRECAST RISERS 12 9' RISERS (TYP.) 4"OSCH40 PVC COMPONENTS H-10 INV'S EL. 2'0 PIPES LEVEL 1ST 2' �2 0' 10.62' 4.0' ..•.•• ENDS SIDES 11.62' ;. . 10- EXISTING 1000 GAL H-10oo " �__� TEE SEPTIC TANK** TEE *� 10 14 ° °'° ° ME211 �0�(] �OOOOO BOO®� ; °000000 11.5f 11.49' TEE SEPTIC TANK TEE 6" MIN SUMP °°°°°°°° . 11.24 000000. o°°° °000 00000°000°oo " p >0o°0°000 r O O O [� O 0 0 O O O O O O O �o°0°0°00 GAS BAFFLE ° ° 12 MIN. INT. DIM. N ;00000000 0�000�����0®�0000��0� 00000000 ,_0°0°0„0„0_ ,°0°0°°°° �0®0���0� O0�00000���°'-00000 GAS BAFFLE :: 1 1.23' 1 1.06' '°00000°o 00000000 8.62' ..• �•.:.:: ..: • • .:::.. •::•.'' �, 4' LIQ. LEVEL (ACME OR EQUAL) 00000ooooo°00000000000000000000a0000o00000iio� LH -20 500 GAL. LEACHING CHAMBERS BY ACME PRECAST 0 00000 0 0 0 0 0000000000000 0 0 0 0 0 0 0 0 n 0000 n0"O„O,,o.,000D0V?oo0°O°0„0'00000. " (9) UNITS REQUIRED 3/4"-1-1/2 DOUBLE WASHED STONE L 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 40' X 10' COMPACTION. (15.221 [2]) N o ( _1% SLOPE) (1 % SLOPE) (1 % SLOPE) d� 46 i FOUNDATIOLEACHING N EXIST. SEPTIC TANK 1' SEPTIC TANK 1' D' BOX 46' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 9 BEDROOMS @ 110 GPD = 990 GPD USE A 990 GPD DESIGN FLOW SEPTIC TANK: 990 GPD (2) = 1980 RE—USE EXISTING 1500 GAL SEPTIC TANK** ADD A 1000 GAL. H-10 SEPTIC TANK LEACHING: 1 SIDES: 2 (80.5 +.12.83) 2 (.74) = 276 GPD BOTTOM 80.5 x 12.83 (.74) = 764 GPD TOTAL: 1406 S.F. 1040 GPD USE (9) 500 GAL. H-20 LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AT SIDES & 2' STONE AT ENDS DCE x#16-117 i j i BEDROOM BEDROOM I BEDROOM FACILITY 4.1' BOTTOM TH-1 NO GROUNDWATER FOUND BATH LIVING DINING BATH 1ST FLOOR FLOOR PLAN NOT TO SCALE BEDROOM ***INSTALLER TO CONFIRM NO GROUNDWATER DOWN TO EL. 3.62 PRIOR TO INSTALLATION OF ANY PORTION OF THE SEPTIC SYSTEM STUDIO STUDIO BEDROOM BEDROOM KITCHEN W/ KITCHEN W/ KITCH BATH FAMILY ROOM BEDROOM I BEDROOM I BATH I (BATH 2ND FLOOR FLOOR PLAN NOT TO SCALE VENT NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H—LQ (H-20 LEACHING) 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP NOT TO SCALE ASSESSORS MAP 61 PARCEL 13 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1 b: SAS TO BE > 3' BUT < 6' BELOW FINISH GRADE (VENT AND H-20 PROVIDED) 1 b: REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 17.8') TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 0 RS DATE: 4/27/16 PERC. RATE _ < 2 MIN/INCH �on9 Pine 1 d Roo St. 15.1' o °� o LS 1OYR 3/2 O J B 28 0 0 LS 24" 1OYR 5/6 13.1' ocu G a o 0J LOCUS MAP NOT TO SCALE ASSESSORS MAP 61 PARCEL 13 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1 b: SAS TO BE > 3' BUT < 6' BELOW FINISH GRADE (VENT AND H-20 PROVIDED) 1 b: REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 17.8') TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 4/27/16 PERC. RATE _ < 2 MIN/INCH CLASS . 1 SOILS 1 ELEV. 0" 15.1' A LS 1OYR 3/2 1 4" J B LS 24" 1OYR 5/6 13.1' I) -N5 DATE C PERC f'erm_it valid for REPAIR Of• Stip IIC SVS'I"H:M11 ONLY., dtuc to State and Local selrtic MS variances. Board. of Ifealtir review and apinoval is rcyuircd fnr any future additions/renu,.+Uons/»Iterations to sewage facilities and/or str•ucrIII es/dI%ellitug. 10YR 7/4 1'a,rrrtouth Heaitfr Ucl'rir•tnucnt 132" 4.1 ' Name Date NO GROUNDWATER ENCOUNTERED TITLE 5 SITE PLAN OF #33 PLEASANIOT STREET SOUTH YARMOUTH, MA PREPARED FOR FALLOWS FAMILY REVOCABLE TRUST DATE: MAY 4, 2016 DATE: NOVEMBER 9, 2016 (REVISED FLOOR PLAN) DATE: NOVEMBER 15, 2016 (REVISED FLOOR PLAN) Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcope.com �0W4 CQ10e e/linee/ 17, iftC. .`' civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-117 FALLOWS.DWG