HomeMy WebLinkAboutEngineered Plans - Rev. 2016TOP OF FOUNDATION EL. 60.0' EL. 58.0' 4" CAST IRON or EQUIVALENT MIN. PITCH 1/4" PER FOOT p SEL. EXISTING EL. EXISTING (DATUM: ASSUMED) ru ko J Q M ti co Z �Q EXISTING TH—\ 4 BR k DUPLEX W EXIST, S.T, Yp/ICS �S 2 BR'S O EACH SIDE 10,5' Q16 0 PROP. S.T. c� O O SEPTIC SYSTEM PROFILE not to scale) INSP. PORT W I 3" OF GRADE 2" of I" o I" DOUBLE WASHED EL. 58.0: PEASTONC OR GEOTEXTILE FILTER FABRIC 4" SCHEDULE 40 PVC PIPE ' FLOW LINE (first 'to be level) ;e000eeeoe MINE I; •°;•, •• -T - 14" EL. 55.5' _ - _ n n n n n ®•�.a O �, C UNa nHrr= 1 1. (FROM 20 S.T.) PRIMARY 3 0.5' CRUSHED STONE OR 4• 1000 GALLON SEPTIC TANK MECHANICAL COMPACTION (EXISTING) BENCHMARK: TOP OF FNDN EL, 60.0' 10'(2%)IN FROM 10 S.T.) 18' 75.85 EL, 54.5' 0 'DOUBLE WASHED F7 FLOW LINE � 14" GAS BAFFLE (SECONDARY) 58 Flaherty Environmental Services SAND P.O. BOX 81 Yarmouth Port, MA 02675 7 774.994.1 166 " VENT IF REQUIRED EL. 55.2'± V - 0o '2020 °0°0Oo �1 --. ® �°0"°5°c oooooo°o° °°°°° BOTTOM OF TEST HOLE EL46.0' USGS ADJUSTMENT: N/A°°0.0- o°° =- ®io0°o°o° 'r 0. 0 0 o°c°o '2 020°0 •,,a o0o0o0o0c 2000.22E EL. 52.5' GROUNDWATER ELEV: N/A IE SOIL ABSORPTION SYSTEM (3) 500 GALLON CHAMBERS WITH 4' STONE AROUND IN A 6.5' 12,83'W X 33.51 X 2'D CONFIGURATION COVERS TO BE WATERTIGHT AND EL. 46.0' BROUGHT TO WITHIN 6" OF FINAL GRADE LOCATIONMAP 1000 GALLON SEPTIC TANK (PROPOSED) N TH EL. 55,0' Buck Island Rd. 18'(2%) TO DBOX 0.5' CRUSHED STONE OR LOCUS MECHANICAL COMPACTION ✓oshua Baker EDVVAR.D UA. STONE No289 p�T ST Sg'1� �' ✓1jZ Ig19 'S0.� 3 .9' SHED 56 �O LOT 109 Ze Ya o th Health Department 16,790 sFt � PVED P ; Name Date 56 SCALE: 1" = 30' REF.' PB 149 PG 95 SH 2 IRL 28 NTS OF Mj F •,= DAV}V D 4, FL�E�F t;/STEL" :NqN TAR\ 1, DATE.' 11/7/2016 REVISED: SITE AND SEWAGE PLAN FOR B & B EXCAVATION, INC./ KAREN M. WATERMAN 144-146 WEST YARMOUTH ROAD WEST YARMOUTH, MA PAGE 1 OF2 GENERAL NOTES 1, ALL PRECAST COMPONENTS TO BE H-10 RATED. ALL COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC TO BE H-20 RATED. 2, THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OFA GARBAGE GRINDER, 3, MUNICIPAL WATER IS NOT AVAILABLE. 4, ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15, 000 AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS, 5. INSTALLER/CONTRACTOR TO REVIEW & VERIFYALL ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL RESPONSIBILITYY, 6, INSTALLER/ CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK AREA, VERIFYING ALL UTILITIES AND NOTIFYING "DIG SAFE" (1-888-344-7233) 72 HOURS PRIOR TO CONSTRUCTION, 7, ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING BY FLAHERTY ENVIRONMENTAL SERVICES AND LOCAL BOARD OF HEALTH. 8. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3' PER 310 CMR 15.000 UNLESS SHOWN PER PLAN, 9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE PUMPED DRY AND FILLED WITH CLEAN SAND OR REMOVED AND REPLACED WITH CLEAN SAND. 10,ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT ACCESS PORTS WITHIN 6" OF FINISH GRADE, 11,ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO BE INSTALLED WATERTIGHT, 12. NO KNOWN WETLANDS OR WELLS WITHIN 100 FEET OF PROPOSED LEACHING, 13, THIS IS NOT A CERTIFIED PLOT PLAN AND UNDER NO CIRCUMSTANCES IS THIS PLAN TO BE USED FOR ZONING OR BUILDING PURPOSES, 14. LOT IS SHOWN AS ASSESSOR'S PARCEL MAP 39 LOT 111. 15. LOCUS PROPERTY IS NOT LOCATED WITHIN ANA QUIFER PROTECTION DISTRICT (ZONE II), DESIGN CALCULATIONS NUMBER OF ACTUAL BEDROOMS 4 (2 BR'S EACH SIDE GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW (I 10 GAUBR/DAYX 4 BR) 440 GAL./DAY REQUIRED SEPTIC TANK CAPACITY - 2 TANKS IN SERIES OR A DUAL COMPARTMENT TANK 880 GAL./440 GAL. SIZE OF SEPTIC TANKS: PRIMARY- 1000 GAL, (EXISTING) SECONDARY- 1000 GAL. (PROPOSED) SOIL CLASSIFICATION 1 DESIGN PERCOLATION RATE < 2 MINANCH EFFLUENT LOADING RATE 0.74 GAL. IDA Y/FT2 LEACHING AREA (2) x (33.5'+ 12.83)(2) = 185 SF 33.5'x 12.83' = 429 SF 614 SFx 0.74 = 454 GPD USE (3) 500 GALLON CHAMBERS WITH 4' STONE AS DIAGRAMMED INA 33.5'X 12.83' X 2' CONFIGURATION RESERVE LEACHING CAPACITY N/A SOIL EVAL UA TION TEST HOLE #1 Evaluator- David D. Flaherty Jr., RS, REHS SE#2755 BOH Witness: Amy VonHone, RS, CHO Date: November 3, 2016 TH-1 ELEV. 58.0' 0--12- 12- "-12"12" - 29" 29--38- EL. 9"-38"EL. 54.8' 38"-144" G.W. ELEV. N/A FILL A/E LS 10YR 4/2 B LS 10YR 5/6 C MS EL. 50.75' 2,5Y614 BOTTOMTH--1 ELEV. 46.0' perc SYSTEM DETAIL Flaherty Environmental Services P. 0. Box 81 Yarmouth Port, MA 02675 774.994.1166 �A OF ss9 EDWARD oyGN a A. STONa ' c N .28 fs . LA sv i /i/ (NTS) ;•r o SITE AND SEWAGE PLAN FOR TION B 8 & Y Jcr, EXCAVATION, 'l certify that on November 12, 2002, l have passed 0 F R. , INC./ the examinatlon approved by the Department of 2 1 KAREN M. WATERMAN Environmental Protection and that the above analysis Qac do 144-146 WEST YARMOUTH ROAD has been performed by me consistant with the CIS TEF' WEST YARMOUTH MA required training, expertise, and experience described yt j g�Aa r in 310 CMR 15.018(2). IIZL�W PAGE20F2(REV.)