Loading...
HomeMy WebLinkAboutReview Checklist° �= z � -r� � = TOWN OF YARMOUTH � SEWAGE PLAN REVIEW CHECKLIST �---- . Location: A.M. �-�, Lot_� Zone of Contribution: In Out Acreage Commercial: Residential: �-----'�' Street: � �� �� -,�.. _..� Village: Floor Plan:� � #Bedrooms:� Owner: /�-l!S'� Insta.11er: ____.___....� ����/! Address: Phone: �=� '-'7/ ��'l Phone: Builder: Engineer: �li 0` Address: � � Phone: ' -- � �� r- r,,�� ,� Phone: i--�- � �7,�z,L -�tZ'/.����i a ���t�C.. .�� , � . � �, G' N/A S NO 1.Re uired#of co ies received .....-/ 2.Date of soils exam and ercolation test not older than 2 ea.rs 3.4-5 ft of naturall occurrin ervious material, above water ta.ble . 4.Foundation 2 ft above hi point of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: � 9.Leaching minimum 100 ft from wetlands Var.: ' 10.Leaching minimum 150 ft from drinkin welU25 ft irri ation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: .t„�'' 12. S stem meets all other setback r uirements Var.: �....� 13.Uses ad'ushnent for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: � 15. System not in to or subsoil(A,B horizons)or 5'removal 16.Pro sed contours are suitable �,,,./' 17. S stem meets slo e r uirements-min. 1/8", '/4" referred 18. S stem meets breakout r uirements PVC liner: Wall: 19. S ecified tee sizes are pro er, as baffle on outlet tee , 20. Sewage is under 10,000 gpd for arcel 21.No garba e dis osal 22. S stem ad uatel sized for its intended use y,_,_� ' 23.Minimum 6"stone or com acted below tank and dbox 24.Manhole covers within 6"of ade, um chamber cover to ade 25.Ins ection ort on lastic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pum system-2" line,weep hole,check valve,tee in dbox, ump size , 28. S tic tank/ um chamber to be factory wat roofed 29.Vent rovided if leachin below 3 feet,under driveway/ arkin 30.Buoyancy calculations for tank/pump cha.mber 31.En ' eer to ins ect and c ' soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stam s/si ature `„� 33.H-201oading is subject to vehicular traffic, oundwater 34.Title V A lication and permit fee, installer si ture 35.Foundation footin min.2 feet above adjusted ound water for new house �.,/ 36.Deed Restriction r uired max. #bedrooms: maa�. flow: d �...- 37.Check area lots for oundwater/Label groundwater in Assessor's Ma Plan reviewed by: �o3io3