HomeMy WebLinkAbout35 Echo Road Site PlanGENERAL NOTES:
A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM
UNLE55 H-20 COMPONENTS ARE USED.
BJ THE DFSIGNEP WILL NOT BE RESPONSIBLE FOP, THE SYSTEM AS DESIGNED UN-
LESS CONSTRUCTED AS SHOWN. ANY CHANGES SHALL BE APPROVED IN WRITING.
C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL
UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK.
CONSTRUCTION NOTES:
1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE,
TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH.
2.) SEPTIC TANK(5), GREASE TRAP(5), DOSING CHAMBER(5) AND DISTRIBUTION
BOX(F5) SHALL BE SET ON A LEVEL 5TA13LF BASE WHICH HAS BEEN MECHANICALLY
COMPACTED, OR ON A G INCH CRUSHED STONE BASE.
3.) SEPTIC TANKS) SHALL MEET A5TM STANDARD C 1 127-93 AND SHALL HAVE
AT LEAST THREE 20' DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT-
TOM OF THE 5E T71C TANK TO THE FLOW LINE SHALL BE 48".
4.) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL. EXTEND A MINIMUM OF G" -
ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE
CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE.
5J RM5E COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST
CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN 6" OF
FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD Of HEALTH AGENT.
G.) PIPING SHALL CON515T OF 4- SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL
BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LE55 THAN I%.
7J. DISTRIBUTION LINES FOR SOIL ABSORPTION SYSTEM (AS REQUIRED) SHALL BE
4" DIAMETER SCHEDULE 40 PVC LAID AT 0.005 FT/FT.. HNE SHALL BE CAPPED
AT END OR AS NOTED.
8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST
2' BEFORE PITCHING TO SOIL AB50RP ION SYSTEM. WATER TEST DISTRIBUTION -
BOX TO ASSURE EVEN DISTRIBUTION.
9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP OF 6" MEASURED BELOW
THE OUTLET INVERT.
10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CONSIST OF 314" TO
1-1/2" DOUBLE WASHED NATIVE STONE FREE OF IRON, FINES AND OUST AND SHALL
BE INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE
SOIL ABSORPTION SYSTEM. BASE AGGREGATE SHALL BE COVERED WITH A 2"
LAYER OF 1/8" TO 1/2" DOUBLE WASHED NATIVE STONE FREE OF IRON, FINES AND DUST.
1 1.) VENT SOIL ABSORPTION SYSTEM WHEN D15TPJBUTION LINES EXCEED 50 FEET;
WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS,
TURNING AREAS OR OTHER IMPERVIOUS MATERIAL; OR. WHEN PRESSURE: DOSED...
12.) 501L ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9" OF
CLEAN MEDIUM SAND (EXCLUDING TOPSOIL).
13.) FINISH GRADE SHALL BE A MAXIMUM OF 3G" OVER THE TOP OF ALL SYSTEM
COMPONENTS, INCLUDING THE SEPTIC TANK, DIST IDUTION BOX, DOSING CHN013fR
AND 501L ABSORPTION SYSTEM. SEPTIC TANKS SHALL HAVE A MINIMUM COVER
of 9.1-
14.)
"14.) FROM THE DATE OF INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL
RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL A850RP- '
TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH
AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM.
15.) THE BOARD Of HEALTH SHALL REQUIRE INSPECTION OF ALL CON5TRUCTIOM ,
BY AN AGENT OF THE BOAPO OF HEALTH (OR THE DESIGNER IF THIS SYSTEM RE-
QUIRES A VARIANCE) AND MAY REQUIRE SUCH PERSON TO CERTIFY IN WRITING
THAT ALL WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE TERMS OF THE
PERMIT AND APPROVED PLANS. 48 HOURS ADVANCE NOTICE I5REQUE5TED.
1 G.) INSTALL A 40 mil HDPE LINER FROM EL 20.7 TO EL 18.7 AS SHOWN ON PLAN.
17.) SOIL REMOVAL: ALL A AND B LAYERS SHALL BE REMOVED FOR D15TANCE OF
OF.5' FROM THE 501, ABSORPTION SYSTEM DO),i TO THE CLEAN SAND EL 17.7j,
AREA TO BE BACKFILLED WITH CLEAN SAND AND COMPACTED TO MINIMIZE
SETTLING.
FLOW PROFILE:
NOT TO SCALE
24" DIAMETER CONCRETE COVER
RAISED TO WITHIN 0 OF FINISH
TOP OF FOUNDATION GRADE (OR AS NOTED)
772,1 EL=25.00 (5EE NOTE #5)
' Proposed EL= 23.20
110" 14"
3"
4'O
1 GAS BAFFLE -
12 1500 GALLON
SEPTIC TANK
501L TEST LOGS:
TEST HOLE. 1 EL= .21.9 -
DEPTH FROM
SURFACE
(INCHES)
501L
HORIZON
SOIL
TEXTURE
(USDA) -
SOIL
COLOR
(MUN5ELL
501L
MOTTLING
OTHER
0-8
Cf
Fill
NA
NONE
G.W. 0, 137"
8-31
B
Loamy Fine Sand
I OYR 6
NONE
PERI P 31'
31-138
CT
Fire Sand
IOYR76
NONE
RATE: <2MINAN
ZONING CLASSIFICATION
ZONE R-25 (RE5IDENMAQ
MINIMUM AREA 25,0005.1`.
MINIMUM FRONTAGE 150 FLET
TEST HOLE 2: EL=20.7±
DEPTH FROM
SURFACE
(INCHES)
SOIL
HORIZON
SOIL
TEXTURE
((JSDA)
SOIL
COLOR
(MIINSELL
501L OTHER
MOTTLING
0-8
E
Loamv Fine Sand
I OYP512
NONE G.W. P 123'
8-3G
B
Loamy Fine Sand
I OYRG/6
NONE
36- 132
C I
fine Sand
I 0YR7/G
NONE
3.9'
E5timated Depih To Hugh Water:
6.5 FEET, EL= 14.4
ZONING CLASSIFICATION
ZONE R-25 (RE5IDENMAQ
DATE OF TESTING: 8-18- 16
PERCOLATION. PATE: LE55. THAN 2-MIN/INCH IN 10 LA R5.
WITNESSED BY: MATTHEW T. FARRELL, ETI, J.M. ORD' Y # ASSOCIATES, INC
AMY VON HONE, AGENT, YARMOUTH
tEALTH DEPARTMENT
USE A LOADING RATE OF 0.74 GPD15F FOR 51ZING OF
SOIL AB50RFIION SYSTEM.
HIGH GROUNDWATER LEVEL CALCULATION
:
/Name I
Depth To Water Table (8-18-16):
10.4 FEET, EL= 10,5
Appropriate Inde%'Well:
MIW-29
Water Level Range Zone:
B (0-3')
Current Depth To Water Level For Index Well (8116):
9.6'
Water Level Adm5tment:
3.9'
E5timated Depih To Hugh Water:
6.5 FEET, EL= 14.4
ZONING CLASSIFICATION
ZONE R-25 (RE5IDENMAQ
MINIMUM AREA 25,0005.1`.
MINIMUM FRONTAGE 150 FLET
FRONT YARD SETBACK 30 FELT
SIDE YARD SETBACK 15 FEET
REAR YARD SETBACK 20 FEET
MAXIMUM BUILDING HEIGHT 35 FEET'
MAXIMUM BUILDI't1('- COVERAGE 25%
'BUILDING HEIGHT MEASURED STREET
SIDE OF FOUNDATION SEE TABLE 203.4.2,
YARMOUTH ZONING BY-LAW
PROPOSED BUILDING COVERAGE
" PT:OPO5ED DWELLING 1,4125Fi
SHED , 97 5r-
C
TOTAL 1.509 5F:t
' Buildinq Area 1,509
Lot Area (100)= 9. 63 O 100)- 16-1%
THREE (3) COVERS TOTAL
IWO SEPTIC TANK AND I DBOX
2" DROP
Lartgest Run
38' 5 -
DE -3
D -BOX
H-20
40 Oj
4' PV 777 4T _ SE
41 `F PROFILE
12;y
x 17
SYSTEM DESIGN CALCULATIONS:
SEWAGE DESIGN FLOW:
2 BEDROOM DWELLING @ 110 GPD = 220 GPD
LEACHING CAPACITY REQUIRED:
3 BEDROOMS (MAX,) @ I 10 GPD = 330 GPD REQUIRED
SEPTIC TANK CAPACITY REQUIRED:
DAILY FLOW = 330 GPD @ 200% = 660 GAL. PEOURR€D
SEPTIC TANK CAPACITY PROVIDED:
1500 GALLON (MIN. ALLOWED)
LEACHING CAPACITY PROVIDED:
ONE (1) 40.0' X I P.O X " LEACHING FIELD CAN LEACH:
Vt= [(40.0 X 1 2.0')] 0.74 GPD/SF=355.2 GPD
355 GPD>330 GPD REQUIRED
NOTE: A GARBAGE DISPOSAL 15 NOT PERMITTED WITH THI5 DESIGN
INSTALL:
ONE (I) - 1500 GALLON SEPTIC TANK
ONE (1) --3 OUTLET DISTRIBUTION BOX (H-20 Rated)
ONE ( I ) 40 0 X 12 9 X 8 NATIVE STONE LEACH FIELD
LOCUS
Yarmouth,
MA
O„
Big Sandy
Pond
v'°% NOT TO SCALE
Exi5tmg Parking Area
TO BE REMOVED `
PPOP05ED 40 MIL HOPE PLAN BOOK 1 10 PAGE 5
LINER SEF NOTE I6 `OL m DEED BOOK 13073 PAGE 187
eGIL
M ASSESSORS' MAP 47 PARCEL 2G
NO,� I9,7 O
LEGEND
Existing 5eniage 5ystem
(Per Health Records)
TO BE REMOVED
4" PVC
INSPECTION PORT
+1 18" #5, REBAR
M FUTURE LOCATION
} Proposed EL= 22.2 (21.4 MINIMUM)
LEACHING I
40.0'x 12.0'x
9" Min - 30 Max
x f�
.4 7.4 0��'�
X
D13OX
t`U� CQ
�Q
FA
SAS PLAN VIEW
SCALE: I " = 10'
LAYER OF 1 /8" - 1/2" STONE
V - 1-112" STONE
=9,3GQ SF±
/
\�k
OO
\1
Z6x' 32 EXISTING CONTOUR
32 PROPOSED CONTOUR
.3 x12,34 EXISTING SPOT GRADE
e O�� 24x5 PROPOSED SPOT GRADE
a °'nom O _W_ WATER SERVICE LINE
-O- OVERHEAD UTILITY SERVICE
-U- UNDERGROUND UTILITY SERVICE
6x -G- GAS SERVICE LINE
\2. TP TP TEST HOLE / BORING LOCATION
ST SEPTIC TANK
DB DISTRIBUTION BOX
SAS SOIL ABSORPTION SYSTEM
x 'ia %1 Reserve RESERVED FOR FUTURE
13r 192 cQ, UTILITY POLE
k lez ® CATCH BA51N
ry b a rO a FIRE HYDRANT
NO�c"X o' ® WELL
�,�i rJ- 1Nq I( ye 0 DRAINAGE MANHOLE _,
0.7 r0BOUND, FOUND
8 S NorP _ T ._ QIB
TQP OF 15ANK
LIMIT OF WORK
/`S\a FENCE
Pas 18.9 EDGE OF CLEARING
e c Exl5ting 1000 Gallon Septic Tank
21.1
BENCHMARK:
Top of PK Nail, EL=23.G--
(1988 NAVE) Datum)
\ Exlstmg 2 Bedroom Dwells IQ
TO BE REMOVED
GAS SERVICE
WATER 5ERVi
Yarmouth health Depart
hent
PP VED
/Name I
)ate
_7777 -
GRAVEL DRIVEW ly Q 7
Muncey Residence
rJo Jim Hagerty, Reef, Cape Cods Home Builder, PO Box 186, West Dennis, MA 02670
20.0 PLgj�J SITE AND SEWAGE DISPOSAL SYSTEM DESIGN
I9.So SCALE 1"70'
35 Echo Road, Yarmouth, MA
INSPECTION NOTE: THIS AREA IS SERVED J.M. OTEILLY & .ASSOCIATES, INC..
5. I'± PR10R TO FINAL INSPECTION BY THE ENGINEER, SYSTEM BY TOWN WATER. Professional Engineering. & Land Surveying Services
NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS.
�-�- EL= 14.4 HIGH GROUNDWATER 1573 Main Street - Route 8A
0 20 40 GO ews r, 1774
3.9' (508)898-8801 Office Brewster, MA 02831 (508)896-6602 Fax
-:-S-FSCALE I "=20'
L=10.5 OBSERVEDGROUNDWATER8/18/16 DATE: 5CALE: BY: CHECK: JOBNUMBFR�
=
91@71 IS I A5 Noted I MTF JMO JMO-8223