HomeMy WebLinkAbout484 WillowC
D
E
1A YARMOUTH DEMOLITION PLAN YARMOUTH FLOOR PLAN
GENERAL DEMOLITION NOTES GENERAL FLOOR PLAN NOTES GENERAL CEILING NOTES
FINISH NOTES: 1. CENTER LIGHT FIXTURES AND OTHER DEVICES IN
A. REFER TO DIVISION 02 SECTION "STRUCTURE DEMOLITION" AND10R L. REMOVE ALL EXISTING WALL CONSTRUCTION, MILLWORK, EQUIPMENT, 1. DIMENSIONS ARE FROM FACE OF WALL TO FACE OF WALL, 1. PAINT ALL WALLS INSIDE AND OUTSIDE DATA CLOSET TO MATCH ACOUSTICAL PANEL "PATTERN" UNLESS OTHERWISE
"SELECTIVE STRUCTURE DEMOLITION" FOR ADDITIONAL DEMOLITION ETC. SHOWN DASHED ON THIS DRAWING IN ITS ENTIRETY TO THE O.E. FACE OF GYPSUM BOARD OR MASONRY) OR FROM FACE EXISTING ADJACENT ROOM. INDICATED. REFER TO DETAIL BELOW.
REQUIREMENTS. EXTENT SHOWN ON THE DRAWINGS. PARTITIONS SHALL BE REMOVED OF EXISTING CONDITION OR FROM COLUMN CENTERLINE, 2. PAINT HM FRAME TO MATCH EXISTING ADJACENT FRAMES.
FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE UNLESSUNLESS OTHERWISE NOTED. DIMENSIONS NOTED AS
3. VCT FLOOR IN DATA CLOSET: JOHNSOMTE AZROCK VCT 2. CENTER ACOUSTICAL PANELS OR GRID IN SPACES
B. COORDINATE PROPOSED METHODS AND OPERATIONS OF DEMOLITION OTHERWISE NOTED."STYLE: V2111 "SPRINGER SPANIEL" UNLESS OTHERWISE INDICATED.
WITH OWNER'S DESIGNATED REPRESENTATIVE PRIOR TO START OF CLEAR" SHALL BE FROM FINISH FACE FINISH FACE, (ie.
FACE OF CERAMIC TILE TO FACE OF CERAMIC TILE). VERIFY COLOR: 55 "SILVER GREY"
DEMOLITION WORK INCLUDE IN SCHEDULE COORDINATION FOR M. AT EXISTING INTERSECTING WALL WHERE ONE WALL HAS BEEN ALL EXISTING DIMENSIONS IN THE FIELD. 4. RUBBER BASE TO MATCH EXISTING 3. SPRINKLER HEADS ARE NOT SHOWN. FIRE PROTECTION
SHUT-OFF, CAPPING AND CONTINUATION OF UTILITY SERVICES AS DEMOLISHED, PREPARE NEWLY EXPOSED AREA OF WALL TO MATCH 5. TRANSITION STRIP AT DOOR SYSTEM INSTALLER SHALL COORDINATE SPRINKLER
REQUIRED. EXISTING ADJACENT SURFACES. 6. CAREFULLY CUT CARPET AT EXTERIOR OF NEW ROOM HEADS. IN AREAS WITH SUSPENDED CEILINGS,
2. PROVIDE MINIMUM 4 -INCH CLEARANCE FROM FACE OF DOOR 7, NEW CEILING IN DATA CLOSETS TO MATCH EXISTING
C. INTERRUPTIONS IN DAILY OPERATIONS MUST BE COORDINATED IN N. EXISTING WALLS INDICATED TO REMAIN ARE FOR PURPOSES OF JAMB TO FACE OF ADJACENT WALL, UNLESS OTHERWISE COORDINATE SPRINKLER MAINS, RUNS AND SPRINKLER
HEAD LOCATIONS WITH OTHER WORK TO INSURE
ADVANCE WITH OWNER'S DESIGNATED REPRESENTATIVE, THIS SHALL ECONOMY ONLY. CONTRACTOR MAY ASSUME, IF MORE EXPEDIENT FOR NOTED.
CEILING HEIGHTS, LIGHTING, DIFFUSER AND OTHER
INCLUDE SERVICE INTERRUPTIONS AND CONNECTIONS, RELOCATION OF CONSTRUCTION OR LESS EXPENSIVE FORTHE OWNER, THAT EXISTING MECHANICAUELECTRICAL NOTES:
OCCUPANTS, REMOVAL OF EQUIPMENT, SHIFTS IN LOCATION OF WORK, CONSTRUCTION MAY BE REMOVED AND REPLACED WITH NEW 3. PROVIDE FIRE -TREATED WOOD BLOCKING OR MINIMUM 1. RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED CEILING DEVICE LOCATIONS ARE MAINTAINED AS
MECHANICAL AND ELECTRICAL DISRUPTION, ETC. ANY OF THE ABOVE CONSTRUCTION ACCEPTABLE TO THE ARCHITECT AT NO ADDITIONAL 0.03124NCH THICK STEEL FLAT STRAP AND BACKING PLATE 2. PROVIDE CAMERA AND CARD READER AT NEW DOORS SHOWN REQUIRED COMPLY WITH APPLICABLE
INTERRUPTIONS REQUIRE A MINIMUM OF THREE FULL WORKING DAYS COST TO THE OWNER. AT, BUT NOT LIMITED T0, THE FOLLOWING LOCATIONS: 3. PROVIDE NEW SMOKE DETECTORS AND MODIFY FIRE ALARM CODE REQUIREMENTS. ADVISE ARCHITECT OF ANY
NOTICE TO THE OWNER. FRIDAY P.M. NOTICE FOR MONDAY A.M. TOILET ACCESSORIES, CASEWORK, MILLWORK, DOOR WALL SYSTEM AS REQUIRED. CONFLICTS WHICH MUST BE RESOLVED PRIOR TO
INTERRUPTIONS WILL NOT BE ACCEPTABLE. BUMPERS, AND ALL OTHER WALL MOUNTED EQUIPMENT OR 4. PROVIDE NEW LIGHTING CIRCUIT AND SWITCH FOR DATA ROOM INSTALLATION.
DEMOLITION KEYNOTES NOTES DEVICES. CEILING LIGHTS- MATCH EXISTING DEVICES AND COLORS.
D. CONDUCT DEMOLITION AND DEBRIS REMOVAL IN A SAFE MANNER TO 5. PROVIDE ELECTRICAL CIRCUITS TO NEW RACKS AS DIRECTED 4. LIGHT FIXTURES, FIRE PROTECTION DEVICES AND
MINIMIZE INTERFERENCE WITH CORRIDORS, HALLS, STAIRS, AND OTHER THE FOLLOWING LIST OF SPECIFIC DEMOLITION NOTES ARE KEYNOTED ON THE BY OWNER, CONNECT TO PANELS AS DIRECTED BY OWNER. DIFFUSERS ARE SHOWN FOR LOCATION AND
ADJACENT FACILITIES AND TO AVOID DAMAGE TO SAME. DO NOT CLOSE DEMOLITION PLANS FOR CONTRACTOR'S REFERENCE: 4. ALL EXISTING PARTITIONS INDICATED TO BE SMOKE
OR OBSTRUCT TRAFFIC WAYS WITHOUT PERMISSION OF THE OWNER. PARTITIONS, SMOKE BARRIERS, OR FIRE -RATED PARTITIONS COORDINATION PURPOSES ONLY. REFER TO
THAT DO NOT CURRENTLY EXTEND TO UNDERSIDE OF ELECTRICAL AND HVAC DWGS. FOR ACTUAL LIGHT
9.01 REMOVE EXISTING SUSPENDED CEILING GRID AND PANEL SYSTEM IN ITS FLOOR SLAB SHALL BE MODIFIED TO EXTEND TO SLAB AND FUTURE, DIFFUSER AND FIRE PROTECTION SCHEDULES.
E. ERECT TEMPORARY ENCLOSURE(S) AROUND ALL EXTERIOR OPENINGS ENTIRETY,
CREATED IN THE BUILDING. THE BUILDING SHALL BE LEFT SHALL COMPLY WITH DETAILS SHOWN FOR NEW PARTITIONS. 5. REFER TO ELECTRICAL, HVAC AND FIRE PROTECTION
WEATHER -TIGHT AND SECURE AT THE END OF EACH WORKDAY. ALL PENETRATIONS OR VOIDS SHALL BE SEALED
9.02 REMOVE EXISTING CARPET AND BASE. DWGS. FOR LIGHT FIXTURES, DIFFUSERS AND FIRE
SMOKE -TIGHT AND/OR BE FIRE -STOPPED AS REQUIRED.
PROTECTION DEVICES IN UNFINISHED AREAS OR AREAS
F. PROVIDE TEMPORARY DUST ENCLOSURES AROUND ALL AREAS OF 12.01 REMOVEIRELOCATE EXISTING FURNITURE - COORDINATE WITH OWNER. WITH EXPOSED STRUCTURE.
WORK. PREVENT DUST, DEBRIS, ETC. FROM REACHING ADJACENT 5. FLOOR PATCH AND FLOOR LEVELING: REPAIR EXISTING
AREAS OF BUILDING. 16.01 REMOVEIRELOCATE ALL EXISTING MECHANICAL, ELECTRICAL, AND FIRE TOPPING SLAB AND CONCRETE FLOOR AT DEMOLITION OF 6. COORDINATE ACCESS PANEL LOCATIONS WITH
PROTECTION DEVICES. REUSE EXISTING DEVICES WHERE POSSIBLE. WALLS AND AT ALL OTHER LOCATIONS AS REQUIRED.
G. REFERTO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND MECHANICAL TRADES; SUBMIT PROPOSED LOCATIONS
SPECIFICATIONS FOR ADDITIONAL DEMOLITION REQUIREMENTS. 6. PATCHING TO MATCH EXISTING TO ARCHITECT FOR APPROVAL.
A) PROVIDE ALL OPENINGS REQUIRED FOR ALL TRADES AND
N. ALL SALVAGEABLE MATERIAL AND EQUIPMENT SHOWN OR SCHEDULED
PATCH TO MATCH EXISTING, AT EXISTING CONSTRUCTION 7. ALL CEILING HEIGHTS SHALL BE AS NOTED ON PLAN.
TO BE REMAIN AS THE PROPERTY OF THE OWNER AND NOT RECLAIMED ALTERED OR DISTURBED BY THE INSTALLATION,
BY THE OWNER PRIOR TO THE BEGINNING OF DEMOLITION WORK SHALL RELOCATION, OR REMOVAL OF HEATING, VENTILATING, AIR 8. ALL SOFFIT HEIGHTS SHALL BE AS NOTED ON PLANS,
BE CAREFULLY REMOVED AND STORED WHERE DIRECTED BY THE CONDITIONING, PLUMBING AND/OR ELECTRICAL EQUIPMENT
OWNER. THE CONTRACTOR SHALL VERIFY WITH THE OWNER ALL ITEMS
TO BE SALVAGED. AND DEVICES.
B) PATCH TO MATCH EXISTING (PTME), ALL AREAS ADJACENT
I. ALL SALVAGEABLE MATERIAL AND EQUIPMENT SCHEDULED TO BE TO, OR DISTURBED BY, NEW CONSTRUCTION OR EXISTING
REMOVED AND NOT REUSED AND RECLAIMED BY THE OWNER SHALL CONSTRUCTION TO BE REMOVED. PATCH TO MATCH
BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE FL
/IIID PLM Al LEGEND INCLUDES FINISH MATERIAL (PAINT OR VWC OR CERAMIC
TRANSPORTED FROM THE SITE AS THEY ARE REMOVED. STORAGE OR LV VF7 LfilY TILE... ETC.) TO MATCH EXISTING.
SALE OF REMOVED ITEMS ON SITE WILL NOT BE PERMITTED. C) PATCH ALL DEFECTS IN, AND FINISH TO MATCH EXISTING,
NEW WALL CONSTRUCTION ALL AREAS WHICH ARE TO RECEIVE NEW MATERIALS,
J. VERIFY SAVING AND REUSE OF ALL MISCELLANEOUS ITEMS AND FINISHES AND ITEMS CALLED FOR IN THE CONTRACT
3.2 Door and Frame Schedule
Bldg
Room
umber
Opug
Door
Frame
Fire
Rating
(Mins)
Glazing
Hard -
ware
Set
Remarks
Rev
Opening Size
Type
Mat
Type
Mat
Detail
Width
Height
Thk
Jamb
Head
Sill
Y
101
AND/OR INSTALLATION OF NEW CONSTRUCTION, INCLUDING
T-0"
7'-0"
1 13/4"
1 F
I WD
I A
I HM
Drawn .....�
ELECTRIC STRIKE
REQUIRED AND RETURNED TO ITS ORIGINAL UNDISTURBED CONDITION
DPH �,. S�AfiD F.
f. p
PVA �rF
1
CLOSER
OR BETTER.
EQUIPMENT NOT SPECIFICALLY LISTED ON THE DRAWINGS OR IN THE
! EXISTING WALLS TO REMAIN
DOCUMENTS. PREPARE ALL EXISTING SURFACES TO
NOTES:
p �+ L�
HARDWARE
HARDWARE SCHEDULE
SPECIFICATIONS WITH THE OWNER PRIOR TO DEMOLITION.
__---___ EXISTING CONSTRUCTION TO BE REMOVED
RECEIVE NEW FINISHES AS REQUIRED.
1.
KD HOLLOW METAL FRAMES
K. UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR THE FINISH
2.
SOLID CORE FLUSH WOOD DOORS- MATCH EXISTING
SET 1`.
SCHEDULE, ALL PORTIONS OF THE EXISTING BUILDING (INCLUDING
EXISTING ITEMS TO REMAIN
10 ly
FOR WOOD SPECIES AND STAIN COLOR.
1111 PAIR BUTTS
FINISHES) DISTURBED BY DEMOLITION OF EXISTING CONSTRUCTION
3.
ALL HARDWARE TO MATCH BUILDING STANDARD.
LOCKSET
AND/OR INSTALLATION OF NEW CONSTRUCTION, INCLUDING
------- EXISTING ITEMS TO BE REMOVED
4.
PAINT DOOR FRAMES TO MATCH EXISTING.
CARD READER
MECHANICAL AND ELECTRICAL WORK, SHALL BE REPAIRED AS
1605902
Drawn .....�
ELECTRIC STRIKE
REQUIRED AND RETURNED TO ITS ORIGINAL UNDISTURBED CONDITION
DPH �,. S�AfiD F.
f. p
PVA �rF
CLOSER
OR BETTER.
• G�9 SAS
FLOOR STOP OR WALL BUMPER
FILEROOM
Dote
www.stamco[L.com
o
m
o
12/22/16
1308
16626
g ; DEPT EQ
i
THIS DRAWING MAY CONTAIN CONFIDENTIAL AND
SENSITIVE COMPANY INFORMATION. EVERSOURCE'S
scale
118A=F-0"AE
10 ly
o
EXISTING CEILING TO
POLICIES FOR PROTECTION OF CONFIDENTIAL AND
Prot Number
REMAIN
SENSITIVE INFORMATION APPLY.
1605902
Drawn .....�
°
DPH �,. S�AfiD F.
f. p
PVA �rF
• G�9 SAS
Checked�Ic• ¢ �%\ 4
RF : o No.3 G
RYa"�
so GLi,STONBUCT
a _
s:
F -Alk
YARMOUTH REFLECTED CEILING PLAN
5A
1/8" = 11_0^
m V E R *5 U K k � t
PARTITION NOTES
ENERGY
SEE DETAIL 5A FOR HEAD DETAIL
1. PARTITION TYPES ARE INDICATED ON FLOOR PLANS.
EXTEND GYPSUM WALLBOARD FULL HEIGHT
PARTITION TYPE
2. PROVIDE MOISTURE RESISTANT G.W.B. AT ALL SOILED UTILITY ROOMS, HOUSEKEEPING
CLOSETS, JANITORS CLOSETS, MECHANICAL EQUIPMENT ROOMS AND WITHIN 10 FT OF ANY SINK
LOCATION UNLESS OTHERWISE NOTED.
CEILING
3. PROVIDE CEMENTITIOUS TILE BACKER BOARD OVER MINIMUM 0.0312" THICK METAL STUD FRAMING
BEHIND CERAMIC TILE WALL FINISH- REFER TO FINISH SCHEDULE.
4. MATERIALS AND CONSTRUCTION OF FIRERATED PARTITIONS, INCLUDING TAPING AND FINISHING OF
GYPSUM BOARD FOR FULL HEIGHT, SHALL BE IN ACCORDANCE WITH DESIGNATED FIRE TEST AND
MANUFACTURER'S DIRECTIONS TO ACHIEVE FIRE RESISTANCE RATING INDICATED. SEAL PERIMETERS
AND ALL PENETRATIONS THROUGH FIRERATED PARTITIONS WITH SPECIFIED FIRE RESISTANT RATED
NEW DA T
3 5/8° METAL STUD
MATERIALS. REFER TO DRAWING A603 FOR TYPICAL THROUGH PENETRATION FIRESTOP SYSTEMS
AND FlRERESISTIVE JOINT SYSTEMS.
5. ALL PARTITIONS SHALL BE SEALED AIRTIGHT FOR FULL HEIGHT INCLUDING PERIEMETER
orm
CIL'
& ALL PENETRATIONS. TAPE AT BOTH FACES & FINISH ALL GYPSUM BOARD JOINTS & FASTENERS.
6. PROVIDE CONTROL JOINTS IN ALL PARTITIONS
30'-0" O.C. MAX FOR GWB PARTITIONS
20'-0" O.C. MAX FOR CMU PARTITIONS.
EVERSOURCE ENERGY
3 5/8° MTL STUDS ® 16" O.C.
STRUCTURAL DECK
3" SOUND ATTENUATION BLANKET
COMPRESSED SOUND ATTENUATION
'®,
SA IIIo w Street t
.71 5,8" TYPE X G.W.B. EACH SIDE
INSULATION AT NON RATED PARTITIONS
BASE AND FLOORING
CONT. ACOUSTIC SEALANT - BOTH SIDES
Yarmouth, NTA 02675
FIRE RESISTANT JOINT SYSTEM AT FIRE
RATED PARTITIONS
METAL EDGE TRIM WHERE EXPOSED TO VIEW
STEEL RUNNER W/ MIN. 2" FLANGES
1 AS SHOWN SEE WALL TYPES FOR WALL CONSTRUCTION
NOTE: m m
FASTEN STEEL RUNNER TO STRUCTURAL DECK . FRICTION FIT METAL STUDS TO RUNNER & FASTEN
G.W.B. TO STUDS - DO NOT FASTEN TO RUNNER. MAINTAIN GAP AS INDICATED BETWEEN
STEEL RUNNER & METAL STUD/G.W.B. TO ACCOMMODATE STRUCTURE DEFLECTION.
m
4A PARTITION TYPES 5A FULL HEIGHT PARTITION -SLIP ANCHORAGE
1 1/2" = 1'-0" 3 = 1-0" '
mm ,
; I
SITE
KEY PLAN
&wnber M/D/Y. Awed For
TOWN OF YARrAOUTH N
iEVIEWED FOR BUILDING AND ZONING CODE COMPLI- C1'
N
ANCE. ERRORS OR GMMIiSSIONS DO NOT RELIEVE THE
APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT" E
COMPLIANCE. '/ 7
0
DATE:
BUILDING OFFICIAL _R
E3
0
a
y
o O
N
O
C
O
O
FLOOR PLANS wlias
O
AND DETAILS
N
O
N
a
E
0
z
a
a
a
Dote
Drawing Number
o
m
12/22/16
i
THIS DRAWING MAY CONTAIN CONFIDENTIAL AND
SENSITIVE COMPANY INFORMATION. EVERSOURCE'S
scale
118A=F-0"AE
10 ly
o
POLICIES FOR PROTECTION OF CONFIDENTIAL AND
Prot Number
SENSITIVE INFORMATION APPLY.
1605902
°