HomeMy WebLinkAboutEngineered Plan - 2016ALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPLETE. 2.5' DEEP IMPERVIOUS BARRIER -120 L.F. OF 40 MIL BARRIER TOP BARRIER=TOP UNITS=30.4, GRADE ABOVE BARRIER=30.8 MIN. OUTSIDE BARRIER RUN GRADE OFF AT 3:1 SLOPE N /F KOPFER 29.7 N /F ; 29.8 9. BURKE ELECTRIC OUTLET PUMP AND CRUSH EXISTING - SEPTIC TANK --OFF LEVEL OUTLET HIGHER THAN INLET. N /F BIANCO 30.5 MAXIMUM FEASIBLE COMPLIANCE APPROVALS REQUESTED: 1. VARY SEPARATION TO HIGH GROUNDWATER BY 1' (4' PROVIDED). 310 CMR "15.212. 2. NO RESERVE AREA IS NOT SHOWN. 310 CMR 15.248. 3. USE ' 6 COVER ' OVER SEPTIC TANK. 310 CMR 15.221 (7). N /F AMICONE 12 +1 j I x .8 29,� Y\.120.00 �-�� -- ---,� 0.2 , �-� =--" 2.3 . t, "� 29-,1 OT 391 --G- o y',1 y 12,600±S.F..305 S -VO PAR - 29.16 332' �3111� pR1VE 9,16 2.461 .%, 0, C....... •:. • ...... :... P AVSD <v x 29?1`x Top oundation x 30,3 0� 30,0 29.03 1 mss. 11 1 1 0.7 X1311331,0 o I J- 1 29.7 ck : 1 O 1 Ex. De 1 1 _� ) 20' i .......... z Z .. 31.5 �1-W x 30.4 1 11 O 1 1 111 J Z 111 II x 9. 0 1 3 3 �. ` -^LI 3.L 2- m""-31,4 x 3 ��-� l-aJ� x 1\� 8,93 16' 3if. li 1 �1 11 31.1 1 1 1 1 1 Ex. 11 1 11 TH 1 1 1 1 1 ed:. 1 _ 1 - 30.9 ` 3L4 2 9.4 4 30.8 01,0 X 3 0.5��.r� BENCH MARK --SOUTH CORNER CONC. BULKHEAD=31.39 ASSIGNED 2 PIECE 1000 GALLON H-10 PUMP CHAMBER W/ SEALANT Quick Disconnect/ DRILL 3/8" WEEP/VENT HOLE Union Recommend Floats re- placeable from top /2„ PVC 29.30 Alar 32" Invert On 25" Check .Valve Off -121 " ff 21" el. 26.88 24.80 6" STONE UNDER Bottom " PERFORMED BY: LEGEND TH 1 TEST HOLE LOCATION, NUMBER W WATER LINE MARKINGS E OVERHEAD ELECTRIC WIRES (IF SHOWN) G GAS LINE MARKINGS` x 9.5 x 31.4 EXISTING- & PROPOSED ELEVATIONS ('X'. MARK /--6-� EXISTING CONTOUR gam--- PROPOSED CONTOUR 0 UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN x - FENCE (IF SHOWN, NOT ALL SHOWN) 0 TREE (IF SHOWN, NOT ALL SHOWN) 1 � 1 ` 30.9 :3u6 I 829.17 31.0 1 x 30.8 x 3 I 11 312.00' K � / I N F ► Ex,02 31.3 LAFONTAINE BENCH MARK --TOP OF PK NAIL 32.0 IN PAVEMENT= 29.17 ASSIGNED HOUSE (19'-6" OFF CENTER NEAR CATCH BASIN) EXIST. NO, 11 JOB NO. _Y16-29 NOTES Richardson.dwg 1. LOCUS IS A.M. 77, PARCEL 186. FB32/21 SB14/18 2: ELEVATIONS'SHOWN ARE ASSIGNED. 3. LOCUS IS IN FLOOD ZONE X(OUTSIDE 0.2% RISK) ON FIRM DATED JULY 16, 2014. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6., COMPONENTS TO BE AASHTO H-10, .UNLESS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE - DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL -FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9, DEPTH OF COMPONENTS NOT TO EXCEED .3', OR VENTING MUST BE PROVIDED. COVERS: BUILD UP COVERS TO GRADE(SECURE COVERS) --1 ON TANK, 1 ON PUMP CHAMBER. 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2- PEA STONE ON- TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS' CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). 13. PUMP AND 'FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. Invert 30.08 Existing PVC Invert 29.98 Existing PVC S=1 /4"/ft Provide 6" c Proposed I NOT TO SCALE LOCATION MAP TEST HOLE 1 DEPTH (inches) ELEV.(fee-t.) 0 30 TEST HOLE DATE: September 29, 2016 9+• PERFORMED BY: Ron Cadillac, Soil Evaluator WITNESSED BY: Amy Von Hone, RS, CHO PERC RATE: .<2'-00" /inch (C layer) o SOIL SURVEY(1993): Carver coarse sand °' GEOLOGIC MAP(1986): Harwich outwash plain deposits 28"n' 28" Invert 29.39 21 ADS ARC 36LP Existing Invert 30.07 CHAMBERS Use Gas Baffle Effluent Filter 70" Proposed Top Units=30.37 :over see detail @ Filter Cloth S=1 /8"/ft f� 3 Max. Fin B layer 1Oyr 5/8 loamy sand C1 layer 10yr 6/6 loamy fine .sand C2 layer 2.5y 7/4. medium sand water __ r:. 25.1 i Invert 29.64 1500 Gal. P I Existing Septic Tank min. TT��r - Inspection Port 131" -observed -20.0 25.06 1 Sanitary Bottom `�h,. Tee 3.8" 136" 19.6 I I Invert 30.24 Invert 30,02 I 29'7 1 » Proposed Pr osed I I 6 Stone or compact I I I I qp 1 4' Bottom BASEMENT FLOOR=25.5 WITH SUMP I , I I , I 1 7'!J'-- 17 ~5 -I 4-4' N 2' I Design Water Table=25.7 PUMPS. USE 25.7 FOR WATER TABLE. gHigh i I i 5 Ground Water=24.2- , IT4.2' DESIGN DATA rn USGS Adl'ustment eptember 2016 BEDROOMS: 3 ash 29 Zone B Observed Woter=20.0 GARBAGE GRINDER: No REQUIRED CAPACITY. 330 GPD __ _ _---------. LEACH AREA - _ -- ---- --- - - , - ---- - ----- --- PROPOSED SEPTIC TANK: 1500 GAL. USE 21 ADS ARC 36LP CHAMBERS EFFECTIVE LEACHING AREA: 496.6 SF IN AN 8'-6" WIDE BY 35' LONG BY 4.73 SF/LF X 5'/UNIT=23.65 S.F/UNIT 3.8" DEEP BED, AS SHOWN. 21 UNITS X 24 SF/UNIT=496.6 SF(EFFECTIVE) > > 5 REMOVAL & 2.5 DEEP BARRIER DESIGN CAPACITY: 367.5- GPD DO 5' ALL AROUND AND UNDER REMOVAL [(496.6 SF) X .74 GPD/SF] DOWN 8" TO B LAYER. USE IMPERVIOUS PUMP CHAMBER RESERVE CAPACITY: 330 GPD BARRIER, AS SHOWN. DOSES PER DAY- 4 BUOYANCY CALC'S-1000 GAL. H-10 PUMP CHAMBER ALARM & PUMP NOTES WEIGHT OF EMPTY CHAMBER AND AVERAGE 10" COVER 1. ALARM TO BE WIRED BY ELECTRICIAN ON CHAMBER= 4.15 ETON (PER ACME-SHOREY) SEPARATE CIRCUIT FROM PUMP. 10' COVER= .83 X 4.83 X 8.5 X 0.055 TON/CU. FT. 2. ELECTRICAL WORK TO BE INSPECTED BY 10" COVER=1.87 TON WIRING INSPECTOR. TOTAL= 4.15 TON + 1.87 TON = 6.02 TON 3. ALARM TO BE LOCATED IN HOUSE, WEIGHT OF WATER= -HIGH GROUNDWATER DOWN 4. PUMP TO BE CAPABLE OF PASSING (25.7 -24.8) X 4.83' X 8.5' X 10.0312 TON/CU. FT. 1-1/4'" SOLIDS AND INSTALLED IN STRICT WEIGHT WATER= 1.15 TON CONFORMANCE WITH MANUFACTURER'S TANK AND 10" COVER ARE HEAVIER BY 4.87 TON. SPECIFICATIONS. 5. USE MEYER SRM4, 4/10 HP PUMP, OR EQUIVALENT. 6. TO PROVIDE FOR EASY AND SAFE MAINTENANCE OF PUMP: -PROVIDE -UNION/DISCONNECT IN 2" PVC THIS PLAN IS A VALID COPY ONLY IF IT BEARS LINE AT TOP PUMP CHAMBER SO PUMP AN ORIGINAL RED STAMWqA ATURE. CAN BE REMOVED FROM TOP OF TANK.' -RECOMMEND FLOATS BE ATTACHED TO 2" PUMP UNE SO FLOATS CAN BE ADJUSTED OUTSIDE CHAMBER. / �St%OFdfAs ' ZHOFMAS Permit valid for REPAIR OF SEI'IIC Sl'SI'F:M �° RONALD Gm �° RONALD GN ONLV_ diie to State and I .oval septic variances. JAMES > JAMES Board of health review and approval is required Ior CADILLAC �CADILLACv v future additions/renu%ations/alterations to #1060 O _P PO S POliV"Age faeilities and/or structures/dwelling• �CISTER� Cq �FSSN oQ- _SANI7ARIP� `i`z40 S, URVEq - Yarmouth Health Department � APPROVED mc` Date HEALTH AGENT APPROVAL .DATE BUOYANCY CALC'S-2 PIECE 1500 GAL. SEPTIC TANK (H-10) DEN WEIGHT OF EMPTY TANK AND AVERAGE 6" COVER CHAMBER= 6.00 TON (PER ACME-SHOREY) BATH 6" COVER= 0.5' X 5.67' X 10..5' X 0.055 TON/CU. FT. BDRM BATH DNRM KIT 6" COVER=1.64 TON TOTAL= 6:00 TON + 1.64 TON = 7.64 TON WEIGHT OF WATER --HIGH. GROUNDWATER DOWN (25.7 -25.06) X 5.67' X 10.5' X .0.0312 TON/CU. FT. BDRM LVRM ENTR WEIGHT WATER= 1.19. TON - TANK AND 6" COVER ARE HEAVIER BY 6.45 TON. SITE PLAN FOR FLOOR PLAN NOT TO SCALE PAIGE 8c LEROY RICHARDSON LOT 3911 7 CAPT. DORE RD, S. YARMOUTH, MA NOVEMBER 3, 2016 SCALE: 1 "=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 PAGE 1 OF 1 2016 B1' R.J. CADILLAC