Loading...
HomeMy WebLinkAboutEngineered Plan - 2016SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE ID. EL. 34.4' 33.0' FILTER FABRIC OVER STONE MINIMUM .75' OF COVER OVER PRECAST ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM WATERTEST D'BOX FOR LEVELNESS BLOCKS OR PRECAST H-10 MIN. 2" WALL THICKNESS PRECAST RISERS RISERS (TYP.) 4"0SCH40 PVC MORTAR ALL + 2'0 PIPES LEVEL 1ST 2' COMPONENTS INVERT IN 28.17 * 28.74' ENDS (nP') SIDES 29.0' • ., .pse�oe ee�oo�_ ... .. ., ..jj .. t '. .n . � .. ' . '.. '. '.. ' .. �' .. •, .. n , `. , o o e.e.o.e.a.e )Q OOOp OoO ®®� >°o°o°aoS 8.49 6" MIN. SUMP °o°O°o°O 00°°°0 0 0000000000°0 ,°°°000°° °°o°°°o °oo�°,c�000^o0 12" MIN. INT. DIM. nj io°0000°000 ®®®®®®®®®®�®®®®®���® ;oo�0000°oo 28.44 28.27 >00000goo OCJ®®����®tea DD®®a��0�fa® :oog00000 ° ° 26.17 �oo°°°°°°°°°o°°°°°°°°o°°°°°°°°°°°°°°°°°° f r °o°o°o°o°opo°o°o°o°o°o°o°o°°o°o°o°o°o°o°o°off `H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUA ,o,,o�o_�_ _n_ .� 0 0 0 o .0 o.�_�_ _�.o.0 0 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. ALL AROUND PRECAST STRUCTURES I(2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE:. 25.00' X 12.83' COMPACTION. (15.221 [2]) 1 ) (1--5% SLOPE) (—L% % SLOPE) (—L% % SLOPE) MIN. LEACHING FOUNDATION— 17' SEPTIC TANK 5' D' BOX 12' FACILITY 21.0' BOTTOM TH-1 NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- EGEND99— 99— 10" 1500 GAL H-10 14" TEE SEPTIC TANK TEE .•. GAS BAFFLE 4' LIQ_ LEVEL (ACME OR EQUAL) . X 99.1 ENDS (nP') SIDES 29.0' • ., .pse�oe ee�oo�_ ... .. ., ..jj .. t '. .n . � .. ' . '.. '. '.. ' .. �' .. •, .. n , `. , o o e.e.o.e.a.e )Q OOOp OoO ®®� >°o°o°aoS 8.49 6" MIN. SUMP °o°O°o°O 00°°°0 0 0000000000°0 ,°°°000°° °°o°°°o °oo�°,c�000^o0 12" MIN. INT. DIM. nj io°0000°000 ®®®®®®®®®®�®®®®®���® ;oo�0000°oo 28.44 28.27 >00000goo OCJ®®����®tea DD®®a��0�fa® :oog00000 ° ° 26.17 �oo°°°°°°°°°o°°°°°°°°o°°°°°°°°°°°°°°°°°° f r °o°o°o°o°opo°o°o°o°o°o°o°o°°o°o°o°o°o°o°o°off `H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUA ,o,,o�o_�_ _n_ .� 0 0 0 o .0 o.�_�_ _�.o.0 0 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. ALL AROUND PRECAST STRUCTURES I(2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE:. 25.00' X 12.83' COMPACTION. (15.221 [2]) 1 ) (1--5% SLOPE) (—L% % SLOPE) (—L% % SLOPE) MIN. LEACHING FOUNDATION— 17' SEPTIC TANK 5' D' BOX 12' FACILITY 21.0' BOTTOM TH-1 NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- EGEND99— 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND C -0b UTILITY POLE Ond FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS *NOTE: INTERIOR PLUMBING TO BE RE-ROUTED TO EXIT THE DWELLING IN LOCATION SHOWN ON PLAN VIEW. PLUMBER TO CONFIRM FEASIBILITY PRIOR TO INSTALLING ANY PORTION OF THE SEPTIC SYSTEM. ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 12/7/16 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS o" 4 FILL 16" ELEV. 32.0' B LS 20" 1OYR 5/3 30.3' C PERC MS 1OYR 6/8 132" I 121.0' NO GROUNDWATER ENCOUNTERED DCE #16-398 Scale: 1"= 20' 0 10 20 30 40 50 FEET FLOORPLAN NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -M 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP NOT TO SCALE ASSESSORS MAP 132 PARCEL 110 SITE IS NOT LOCATED WITHIN A ZONE II SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING - - - DESIGN FLOW:- 3 -BEDROOMS 05 110 GPD 330 GRID USE A 330 GPD DESIGN FLOW Yarmouth Health Department Pp V.ED arae Date � �ZN OF 44,qsS.- DAN[ DANIELA. OJALA CIVIL No. 46502 �a &GfSTel?, , a ss�ONAL N j SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE IN OF hfj 6 gc`a�t DANIEL yGs A. OJALA CA No. 40980 P { 0 ess\o "!VD SUR11E�a DATE DANIEL A. OJALA, P.E., P.L.S. , MA BOARD OF HEALTH TITLE 5 SITE PLAN OF 114 CENTER STREET YARMOUTH PORT, MA PREPARED FOR MARK STANLEY DATE: DECEMBER 8, 2016 F. off 508-362-4541 fax 508-362-9880 downcope.com 0OW/1 cape eftkeeriV f kC. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16.398 STANLEY.DWG O° Locus m M hew tea° Ond o � t LOCUS MAP NOT TO SCALE ASSESSORS MAP 132 PARCEL 110 SITE IS NOT LOCATED WITHIN A ZONE II SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING - - - DESIGN FLOW:- 3 -BEDROOMS 05 110 GPD 330 GRID USE A 330 GPD DESIGN FLOW Yarmouth Health Department Pp V.ED arae Date � �ZN OF 44,qsS.- DAN[ DANIELA. OJALA CIVIL No. 46502 �a &GfSTel?, , a ss�ONAL N j SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE IN OF hfj 6 gc`a�t DANIEL yGs A. OJALA CA No. 40980 P { 0 ess\o "!VD SUR11E�a DATE DANIEL A. OJALA, P.E., P.L.S. , MA BOARD OF HEALTH TITLE 5 SITE PLAN OF 114 CENTER STREET YARMOUTH PORT, MA PREPARED FOR MARK STANLEY DATE: DECEMBER 8, 2016 F. off 508-362-4541 fax 508-362-9880 downcope.com 0OW/1 cape eftkeeriV f kC. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16.398 STANLEY.DWG