HomeMy WebLinkAboutEngineered Plan - 2016— —101---- EXISTING CONTOUR z
Ao s
x 100.98 EXISTING SPOT GRADE a ° w
Rte
W —EXISTING WATER SVC. Ma'n
G EXISTING GAS SVC.�� N
—B.H.•I4—OVERHEAD WIRES Q N Exeter Rd
,o TEST PIT 2 z a: H
u er n
Q� cti
>> 1i0• BENCHMARK Q Brookhill Lo
PramAve
LEGEND n Cutter Ln 5
CUTTER LANE
a v N
�o
U
' `v z Yacht Ave
°' N
LOCUS �
100.33 edge of 99,56 pavement 98,23 97'68
100.79 ®
Permit valid for NH.1'A!R CIH SN PTI(. SYSI N;M Silver Leaf Rd
' Rainbow Rd
�-- 97.71
ONLY, dire to State and Local septic variances.
10000,_1 -� ='--�_
I Board of'ttealth review and approval is required 1'vr
LEWIS BAY
�TO
�� R=465.88'
10050 ' S 34'34'20" any future additions/rcnoroations/alterations to
1417; 0 x•10 x 100.3\
'
E sewage facilities and/or structur es/dwelling.
LOCUS MAP
9 83
Yarmouth Health Department NOT TO SCALE
102,50
APPROVED/��% GENERAL NOTES:
1.78
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
02.63
_ / BOARD OF HEALTH AND THE DESIGN ENGINEER.
ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
102,89 LOT 12
I 1 Namc Date OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
'LOCAL
RULESR(b)LATIONS, EXCEPT AS REQUESTED BELOW:
10,800 ±SF
—310 CMR 15405(
WAL - 10 ,24
11133 f
1) A 6' variance, S.A.S. to cellar wall space wall, for a 14' setback.
0 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
�... .,
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
D• ,. ,>
-C:.. O
W
� DESIGN ENGINEER.
.p
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
0
EXISTING O
c
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
O BEFORE CONSTRUCTION
00 103.28 03,43 /
ENGINEER CONTINUES.
HOUSE(#38)
5. ALL ELEVATIONS BASED ON an ASSUMED DATUM.
T.O.F.=104.07±
X 102,77 / //
pi //
THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
PROPOSED SEWER CONNECTION 7• THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
IN
INV.=101.07(VERIFY) 8'
Z
0
WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
SHR
BENCHMARK THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
CONCRETE
ORANGE PAINT ON 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
103,39 PATIO O 103,
0 103.50 1103,08 —
BULKHEAD CORNER AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
EL.=103.20 DIRECTED BY THE APPROVING AUTHORITIES.
103,44 S.A,S,:.':,;�
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
P 02,8
CONSTRUCTION.
E.OSTING LEACH PIT
SHED
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
Co ;: ; :. :• : "i i
PUOP, FILL WITH SAND & IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
,
STG. ;� 3 62
ABANDONED, OR REMOVED REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
TENT
'
103,
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
O^�, A?5
F\,
103,6X r- �
EXISTING CESSPOOL INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
16.04 J Jj
90,78tTO
BE REMOVED 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
�� fence
NOT CONSIDERED TO BE A PROPERTY LINE SURVEY.
W line t
50 N 34�34'2Q" yp,
N 4627
PROPOSED SEPTIC TANK 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC
ofgssq�y �� �— W
COMPONENTS NOT SHOWN oTHE
g PETER T.
McENTEE JOHN
o "'�� Co L'
PROPOSEDsYSTEM
SEPTIC SYSTEM UPGRADE PLAN
15 CUTTER LANE, WEST YARMOUTH, MA
URC II L
OWNER OF RECORD
NoC135109 R ��
g
BISHOP, JOSEPH A Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632
�'
GIST-�E tF� i► d' F
BISHOP, CYNTHIA G Engineering by: Surveying by: SCALE DRAWN JOB. NO.
OF
ON ��
P.O. BOX 135 221-16
Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M.
N
MENDON, MA 01756 12 West Crossfield Rood 2854 Cranberry Hwy.
DATE CHECKED SHEEP N0.
n //�� Forestdole, MA 02644 E.Worehom, MA 02538
2L
PARCEL 1D: -131 (508) 477-5313 (508) 273-0377 10/10/16 P.T.M. 1 Of 2
A
SEPTIC TANK
INSTALL RISERS & COVERS OVER INLET &
OUTLET AND SET TO 6" OF FINISH GRADE
T.O.F= 1 04.07±
-F.G. EL.=103.1±
L= 9'
®S=1% (MIN.)
4"SCH40 PVC
INV.=100.75
F.G. EL.=103.0±
3'(max.)
1 4..
48" LIQUID -
LEVEL ADD
GAS BAFFLE
-J PROPOSED SEPTIC TANK
CONNECT TO EXISTING SEWER PIPE
OUTSIDE HOUSE, INV.=101.07(VERIFY)
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES &
INVERTS EXITING HOUSE, PRIOR TO INSTALLATION.
2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND
TRUE TO GRADE ON A MECHANICALLY COMPACTED
SIX INCH CRUSHED STONE BASE, AS SPECIFIED
IN 310 CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
DESIGN CRITERIA
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SHALL NOT BE AT, OR BELOW, EL.=100.50
FOR A DISTANCE OF 15' FROM THE EDGE
PROPOSED D -BOX OF THE PROPOSED S.A.S.
INSTALL RISER & COVER PROPOSED S.A.S.
SET TO 6" OF GRADE INSTALL RISER & COVER OVER ONE CHAMBER AND
SET TO 3" OF F.G. TOI SERVE AS INSPECTION PORT
F.G. EL.=103.5±F.G. EL.=103.5±
,� MAINTAIN 2% SLOPE OVER S.A.S.
L=21'
0S=1% (MIN.)
4'SCH40 PVC
L=5'
® S=1% (MIN.)
4"SCH40 PVC
INV.= 100.27-/ PROPOSED=1004' 4.8' 4'
0
D BOX INV..1EFFECTIVE WIDTH = ',12.8'
NV.=100.50 3 OUTLETS �
INV.=100.00 2-500 GALLON LEACHING CHAMBERS
SURROUNDED WITH STONE i AS SHOWN
r
H-10 RATED
TOP CONC. ELEV.=100.8±
BREAKOUT ELEV.=100.50
INV. ELEV.=100.00 ®®oa®
BOTTOM ELEV.= 98.00
4' OF NATURALLY OCCURRING
PERVIOUS MATERIAL
5' (MIN.) ABOVE G.W.
BOTTOM OF TEST PIT, EL.=92.0
SEPTIC SYSTEM PROFILE
NUMBER OF BEDROOMS: 2 BEDROOMS
SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF)
DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 220 GPD
DESIGN FLOW: 330 GPD
GARBAGE GRINDER: NO -not allowed with design
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
.74 GPD/SF
PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED
USE 2-500 GALLON LEACHING CHAMBERS IN SERIES
SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES
SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F.
BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F.
TOTALAREA: .............. ............................................... 471.2 S.F.
DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD
-2- LAYER OF 1/8- TO 1/2"
DOUBLE WASHED STONE
(OR APPROVED FILTER FABRIC
3/4" TO 1-1/2" DOUBLE
WASHED STONE
EXISTING' /
HOUSE(#38)
T. 0. F. = 104.07±
N
17.9'-N06-;'� `L
SHED PROPOSED
3S, �� S.A.S
.I
SEPTIC LAYOUT
4' 1. 2 x 8.5' 17.0' 4'
EFFECTIVE LENGTH = 25.0'
LEACHING SYSTEM SECTION ® E3 E3 E3 0 E3 E3 E3 E3
®®®®®®®®®®® 33„
�w
® Ea ®®®®®®®®
NZTU®®®®®®®® ®®
102"
SOIL LOG
DATE: OCTOBER 6, 2016
SOIL EVALUATOR: PETER MIENTEE PE(SE#1542)
WITNESS: PHIL RENAUD R.S. HEALTH AGENT
ELEV. TP DEPTH
103.5 1 0
M -F SAND
2.5Y 6/6 `,
92.0 ' ' ' 138"
PERC RATE <2 MIN/IN. "C" HORIZON
NO GROUNDWATER ENCOUNTERED
B
PLAN
15 CUTTER LANE, WEST YARMOUTH,
4" KNOCKOUT
LOAMY SAND
Brown, Inc., P.O. Box 145, Centerville, MA 02632
20" DIA. COVER
102.8
100.7
10YR 4/21
4" KNOCKOUT0 / 4" KNOCKOUT
4" KNOCKOUT
g"
PERC
12'/30"
34'
B
LOAMY SAND
10YR 5/4
I
C
M -F SAND
2.5Y 6/6 `,
92.0 ' ' ' 138"
PERC RATE <2 MIN/IN. "C" HORIZON
NO GROUNDWATER ENCOUNTERED
500 GALLON CAPACITY, H-10 LOADING
CHAMBERS
N.T.S.
58"
PROPOSED
SEPTIC SYSTEM UPGRADE
PLAN
15 CUTTER LANE, WEST YARMOUTH,
4" KNOCKOUT
Prepared for: D.A.
Brown, Inc., P.O. Box 145, Centerville, MA 02632
20" DIA. COVER
Surveying by:
JC Engineering, Inc.
2854 Cranberry Hwy.
E.Warehom, MA 02538
(508) 273-0377
SCALE
N.T.S.
4" KNOCKOUT0 / 4" KNOCKOUT
4" KNOCKOUT
JOB. N0,
221-16
DATE
10/10/16
500 GALLON CAPACITY, H-10 LOADING
CHAMBERS
N.T.S.
58"
PROPOSED
SEPTIC SYSTEM UPGRADE
PLAN
15 CUTTER LANE, WEST YARMOUTH,
MA
Prepared for: D.A.
Brown, Inc., P.O. Box 145, Centerville, MA 02632
Engineering by:
Engineering Works, Inc.
12 West Crossfield Road
Forestdale, MA 02644
(508) 477-5313
Surveying by:
JC Engineering, Inc.
2854 Cranberry Hwy.
E.Warehom, MA 02538
(508) 273-0377
SCALE
N.T.S.
DRAWN
P.T.M.
JOB. N0,
221-16
DATE
10/10/16
CHECKED
P.T.M.
SHEET NO.
2 Of 2