Loading...
HomeMy WebLinkAboutEngineered Plans - 2016—1---- 01 EXISTING CONTOUR o 01 PROPOSED CONTOUR VINE BROOK RD N x 100.98 EXISTING SPOT GRADE 1/11 EXISTING WATER SVC.�F°`O --$.H.-K4 --OVERHEAD WIRES EXISTING CESSPOOL s9 boy TO BE PUMPED, FILLED TEST PIT 9 h2F WITH SAND & ABANDONED _?c •�} BENCHMARK \ N 47° 28' 10') W ` �. � x 100.00' 'D00,55 99,83 ' '~ `� x 1 0,64 LEGEND T do x 100:32 f SHED 99,83 x 15' 15' WIDE `' DRAINAGE 6 LOCUS HAZELMOOR RD m N (n .. EASEMENT o 4+ o x Pa' O 10 .64 100,44 PROPOSED SEPTIC TANK Av JOYCE ST zz x TP N LOCUS MAP x . ' 100,1 1•0: f x (��J '. ' 100:54 NOT TO SCALE GENERAL NOTES: 101,9 o 100.58 �� ; 17 BENCHMARK 0 �'•'.K. !',. ';'� BULKHEAD CORNER 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL 1 0:87/ Q EL. =101.75 BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS ani� / 10016 x �–.�' OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE 00:A (01,17 ^) ( LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: i 100,57 DECK –310 CMR 15,405(1)(b): CONTENTS OF LOCAL UPGRADE APPROVAL Q) x 0:48 �, EXISTING CESSPOOL 1) A 4' variance, S.A.S. to cellar wall, for a 16' setback. - � 4" SEWER x 1100:96 TO BE PUMPED, FILLED 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR ' INV.=99.77E Z WITH SAND &ABANDONED TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE x 100,82 DESIGN ENGINEER. v, p N 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING po .EXISTING B HOUSE(f17) 101.75 O FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION "CONTINUES. 1 M T.O.F.=101.6E 0". 5. ALL ELEVATIONS BASED ON an ASSUMED DATUM. °cV 100:81 4" SEWER6. 100,79 THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF d INV. –99.77E m I THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF V) lid for REPAIR OF SEPTIC SYSTEM' 100:93 I PORCH HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. Permit ONLY;. Me to State and I.ocal septic variances. � x x 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. Board o lealth review and approval is required for, 100,72 100.75 ,• 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS fu t re add itionstrenov,Itions/alterations to ,rte AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE any sewage t ilities and/or structiorcad«=it�s,l . 100.89 �p? JS DIRECTED BY THE APPROVING AUTHORITIES. Y00 88 r� x 100:64 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY armouth Hcaltb Uehao tenent 100:50 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING ��I)/ APPROVED/ 0 to Q LOT 30 X CONSTRUCTION. WHERE REQUIRED, SHALL REMOVE ALL UNSUITABLE SOILS 11. CONTRACTOR 12,000 ±SF a OF MAssgcy IN THE AREA OF HE AND ONLNS310 BCL CONCRETE.':. CID� EA SANDASANDRSPECIFIED5' �P��H REPLACE WITH 310CM Q00.28 0 T. 12 SHALL BE I IABTO Date " . M NT EE �- INSPECTED BY DESIGNIPO GINOEERUPRIOR BACKFILL. n>te x 100.00' o CIVIL v 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND No. 35109 NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 100,59 S 47°28'10" E `. 100:27 REGI$TER�� ��� 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC THE PLAN SYSTEM COMPONENTS NOT SHOWN ON 89 PARCEL ID: 78-179 100,92 100.58 edge of pavement 100.08 PIK100. SETCATC�9 BASIN ZZ' 2� PROPOSED SEPTIC SYSTEM UPGRADE PLAN l ROAD ANTLERS O A JJ REVISION 17 ANTLERS ROAD, SO. YARMOUTH, MA 1 ►, 12/ 12/22/16 1) ADD DRAINAGE EASEMENT 2) S.A.S. LOCATION Prepared for: DiBuono Sewer & Drain, 8 John's Path, S. Yarmouth, MA 02664 OWNER OF RECORD Engineering by: Surveying by: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. 1 "=20 P.T.M. 243-16 RAINIER A. SILVA 12 West Crossfield Road 2854 Cranberry Hwy. / 94 ARROWHEAD DRIVE Forestdale, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO. HYANNIS, MA 02601 (508) 477-5313 (508) 273-0377 12/5/16 P.T.M. 1 of 2 r SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE T.O.F=101.6± -F.G. EL.=100.5± L = 44'(MAX.) @S=1% (MIN.) 4"SCH40 PVC IR1�T�". F.G. EL.=101.3± 3'(max.) 1 14.. 48" LIQUID LEVEL ADD GAS BAFFLE CONNECT TO EXISTING SEWER PIPES AT HOUSE, AT OR ABOVE, INV.=99.77 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA PROPOSED D -BOX INSTALL RISER & COVER SET TO 6" OF GRADE L=54' @ S=1% (MIN.) 4"SCH40 PVC F.G. EL.=100.7± L= 5' ® S=1% (MIN.) 4"SCH40 PVC NOTE: TO PREVENT BREAKOUT, FINAL GRADE SHALL NOT BE AT, OR BELOW, EL.=97.6 FOR A DISTANCE OF 15' FROM THE EDGE OF THE PROPOSED S.A.S. PROPOSED S.A.S. INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT r F.G. EL.=100.7± MAINTAIN 2% SLOPE OVER S.A.S. INV. =97.37- PROPOSE_D 4' 4.8' tNV.=97.20 NV.=99.00 � EFFECTIVE WIDTH = 12.8' 3 OUTLETS INV.= 97.10 -500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN H-10 RATED TOP CONC. ELEV.= 97.9± BREAKOUT ELEV.= 97.6 INV. ELEV.= 97.10 - I a & 92aa BOTTOM OF S.A.S., ELEV.= 95.10- 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL 5' (MIN.) ABOVE G.W. BOTTOM OF TEST PIT, EL.=90.1 SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED USE 2-500 GALLON LEACHING CHAMBERS IN SERIES SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. TOTAL AREA: .............................................................. 471.2 S.F. DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD -2" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC 4' I 2 x 8.5' = 17.0' 1 4' EFFECTIVE LENGTH = 25.0' " TO 1-1/2" DOUBLE WASHED STONE SOIL LOG DATE: NOVEMBER 21, '2016 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: PHIL RENEAUD R.S. HEALTH AGENT ELEV. TP DEPTH 100.4 011 FILL 98.6 22" 96.4 A LOAMY SAND 10YR 4/2 B LOAMY SAND 10YR 5/8 C M -C SAND 2.5Y 6/6 28" PERC 32"/40" 48" 90.1 1 ADJ. G.W. 88.4 STG. G.W. 144" 88.3 1 145" PERC RATE <2 MIN/IN. "C" HORIZON STANDING G.W. @ 144 (EL.=88.4) INDEX WELL, AIW-230, ZONE B, ADJUSTMENT=1.7', NOV 2016, EL.=91.1 PERC RATE <2 MIN/IN. ("B & C" HORIZONS) SEPTIC LAYOUT til til t=1 t�f 1�1 t�f t�1 tit til t�f t�f � = (tel t�f t�1 1.f 11 t�f t�1 til t�1 til t=f 500 GALLON CAPACITY, H-10 LOADING CHAMBERS N.T.S. 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 17 ANTLERS ROAD, SO. YARMOUTH, MA Prepared for: DiBuono Sewer & Drain, 8 John's Path, S. Yarmouth, MA 02664 Engineering by: Surveying by: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 243-16 12 West Crossfield Road 2854 Cranberry Hwy. Forestdale, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO. (508) 477-5313 (508) 273-0377 12/5/16 P.T.M. 2 of 2 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT0 / 4" KNOCKOUT 4" KNOCKOUT 500 GALLON CAPACITY, H-10 LOADING CHAMBERS N.T.S. 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 17 ANTLERS ROAD, SO. YARMOUTH, MA Prepared for: DiBuono Sewer & Drain, 8 John's Path, S. Yarmouth, MA 02664 Engineering by: Surveying by: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 243-16 12 West Crossfield Road 2854 Cranberry Hwy. Forestdale, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO. (508) 477-5313 (508) 273-0377 12/5/16 P.T.M. 2 of 2