Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2016LOCUS DATA CURRENT OWNER RICHARD GENTILE PLAN REFERENCE 72-57 DEED REFERENCE 29441-235 ZONING DISTRICT R-25 FLOOD ZONE AE -11 ASSESSORS MAP 34 PARCEL 224 OVERLAY DISTRICT NONE UPLAND LOT AREA 10,294± S.F. SITE & SEWAGE REPAIR PLAN #88 BREEZY POINT ROAD IN S. YARMOUTH, MASS DATE: MAY 18, 2016 REV: SEPT. 23, 2016 OWNER/APPLICANT: RICHARD J. GENTILE 88 BREEZY POINT ROAD S. YARMOUTH, 02664 (603) 930-6857 SHEET 1 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU RVEY@YAH 00. COM BENCHMARK CENTER OF DRAIN MANHOLE. EL 4.79 BVW#1 E 263'± N g1.16'50 \ BVW#2 \ PROPOSED —� 1,500 GALLON ����. MONO SEPTIC \ TANK. \ ED#2 BED# \ WATERPROOF \AT FACTORY \ BVW#3 ED#3 BATH \ #88 LIVING KI HEN ROOM 6.2x DECK P-1 z 28 SrReEr v o M Z N 0 o N 0 0 D 0 LOCUS LOCUS MAP NOT TO SCALE: 16-0107 BVW#4 61.9' 1 4.5x L 0 T 33 34 & 35 PROPOSED 650 GALLON \ PUMP CHAMBER WITHBVW#5 \ I 10,294± S.F. UPLAND OUTSIDE CONTROL BOX tK via PROPOSED MP \`- LEACHING (32)\ OPOSEDT FENCELz TCHAMBERS \ #92 \1/ BVW#7 -- Permit valid for RF;PAIR M' SEPTIC SYS"t'EM ONLY; due to State and I n.al septic variances. Board, of Ilealth review ano approval is required for any, future additions/reuti.iitiunsialterations to EXISTING sewage facilities and/or structof esidwelting. LEACHING AREk Yarmouth 11calltt t)cpartment TO \'( LOCATTEDEAN[ APPROVIFU ��� REMOVED FRO A�.� PROPERTY. 4y �- ame Date N 8 V 16' S0' H of �ss9 EDWARD cyG o A STO 0 20 30 40 0.2 8 o- s 'v L L NO GRAPHIC SCALE: 1 INCH = 20 FEET TOP OF FOUNDATION ELEV. 7.36 CRAWL SPACE I�f. JOB # 16-0107 INV.= I III c m"' 4.87 10"TEE FINISH GRADE ELEV. 7.0 14"TEE ZABEL FILTER RAISE (1) 24" COVERS TO FINISH GRADE RAISE (2) COVERS TO WITHIN O 6" OF FINISH GRADE FINISH GRADE PUMP ELEV. 6.7 CONTROLS, 1 O'OS= 0.015 4" PVC SCH 40 INV.= 4.70 • 4' " -6 1/2 4'-1" LIQUID LEVEL 5'-7" WATER EL=1.6 4'-5"1 WATER BOT. 1P4 o EL=1.6 e (0.33) BOT. PROPOSED 1,500 GALLON MONO SEPTIC TANK (-1.12) SET ON 6" STONE OR LEVEL STABLE BASE WATERPROOF AT FACTORY 4" DIA MIN. MANHOLE r)\/PR RR(lllnWT Tn EL 7.0 TOP 5.63 WEIGHT .. 10' OF 2" � PVC SCH 40 OF SOIL= INV.= INV.= 4.55 4.55 888 SITE & SEWAGE REPAIR PLAN //88BRE-E-Z y POINT ROAD IN S. YARMOUTH, MASS DATE: MAY 18, 2016 REV: SEPT. 23, 2016 OWNER/APPLICANT: RICHARD J. GENTILE 88 BREEZY POINT ROAD S. YARMOUTH, 02664 (603) 930-6857 SHEET 2 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM PROPOSED 650 GALLON PUMP CHAMBER SET ON 6" STONE OR LEVEL STABLE BA WATERPROOF AT FACTORY SE TOP ELEV. = 6.3 1 4" PVC INV.= 4.55 a � � v ALARM ELEV.= 1.96 LO PUMP ON EL. = 1.63 PUMP OFF EL. = 0.96 BOT. INS. = 0.13 Rr1T FI = (-(145) v 4"x8"x16" SOLID CONCRETE BLOCK O. I I�� WEIGHT .. 6,080 � WEIGHT OF SOIL= ■ I • WEIGHT OF COLLAR= 888 o -ou ouou�o ou ou..ou IN. 3/4" TO 1 1/2" STONE 650 GALLON H-20 PRECAST CONCRETE PUMP CHAMBER PUMP CHAMBER BUOYANCY CALCULATIONS 650 GALLON H-20 WITH COLLAR AT BOTTOM WEIGHT OF TANK= 6,080 LBS WEIGHT OF SOIL= 2,670 LBS WEIGHT OF COLLAR= 888 LBS TOTAL WEIGHT= 9,638 LBS BUOYANCY FORCE: 4,923 LBS 4,923 f LBS < 9,638 + LBS= 4,715 + LBS UPLIFT TANK/SOIL COLLAR/SOIL RAISE COVER TO WITHIN 6" OF FINISH GRADE ELEV. 7.3 2" TO 4" EXPANDER LINER 6' 6 OUT H-10 INV.= 6.2 HORIZ. "T" tNOFMA�_ GR D E SE / 3C EW ON CAP ATION PORTS TO FINISH GRADE ELEV. 7.2 GROUND/ELEVATION 7.2 "z///-, `\ / //�\ 9" OF COVER �\ TOP ELEV 6.37 ! rilc PROPOSED 40 MIL POLY LINER. TOP 6.5 BOT. 4.0 TOP 7.0 � BOT. 5.7 (24) LOW PROFILE QUIK-4"s INFILTRATORS INV.= 5.97 3 ROWS OF 8 UNITS 7_1 INV.= .03 EACH UNIT 34" x 48" x 8" o 0 88808888888 aof88888888888 32.0' o SEE DETAIL #1 11.33'x24.0' LEACHING AREA 4 ui -ELEV. 1.6 ELEV. 5.70 ADJ. G.WATER TH#1 FH K. 12 0 _GISTE�� SAN TAR\P� LINER cl c APPROX. 9" COVER �---QUICK DISCONNECT 2" PVC DISCHARGE PIPE INV 4.55 1/4" WEEP HOLE CHECK VALVE ADJ. G.WATER 2" SCH 40 ' ELEV. 1.6 PVC THREADED PIPE 2 MERCURY FLOAT LEVEL CONTROLS MYERS 0.4 HP � SEWAGE PUMP (MODEL SMR) LOCATE UNDER MH OR EQUIVALENT PUMP TO HANDLE MIN. 2" SOLIDS DOSING CALCULATIONS: OBSERVATION PORT(S) \ SCREW CAP SAND FILL MIN 6" SAND FILL T �-- 2.83' -+- 2.83'---+-- 2.83'-- 8.5' 15.5' OVERDIG SIDE VIEW STRIPOUT TO TOP OF "B" HORIZON PER 310 CMR 15.255 (C) TOWN OF YARMOUTH REQUIREMENTS 1.) SURVEYOR TO STAKEOUT LOCATION OF WALL. 2.) ENGINEER TO INSPECT OVERDIG 3.) ENGINEER TO INSPECT WALL FOOTING 4.) ENGINEER TO INSPECT S.A.S. & PUMPS DETAIL #1 3" CAP TOP 7.0 T 10" BLOCK BOT. 5.9 j VERSA LOC WALL OR 10" BLOCK `� TI APPROVED EQUAL 16' 6" GRAVEL88888888888 00000000000 00000000000 DESIGN FLOW TO CHAMBER = 330 GPD REQ'D EMERGENCY STORAGE = 330 GAL EMERGENCY STORAGE PROVO = 380 GPD (2.59' x 146.87 G/FT) NUMBER OF DOSING CYCLES = 4 PER DAY/TITLE V DEPTH PER CYCLE 0.67' = 8" INCHES 87 AlGDOSE SEPTIC TANK BUOYANCY_ CALCULATIONS 1,500 GALLON H-10 WEIGHT OF TANK= 11,480 LBS WEIGHT OF SOIL= 7.204 TOTAL WEIGHT= 18,384 LBS 0.67 x 146. = 98.4 / BUOYANCY FORCE: 4 718 LBS DESIGN TDH (1.56'+8.72') = 10.28 < 12.4 CHART CSD 40 GPM ' DESIGN GPM = 40 GPM 4,718 � LBS < 18,384+ LBS =13,966 + LBS RUNNING TIME = 98.4 GAL - 40 GPM = 2.46m UPLIFT TANK/SOIL +/or 2 MIN 28 SEC. CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED PUMP NOTES 1. POWER CABLES TO BE PLACED IN CONDUIT IN ACCORDANCE WITH LOCAL BUILDING AND WIRE CODES. 2. PUMP AND ALARM TO BE ON SEPERATE ELECTRICAL CIRCUITS. 3. PUMP ALARM TO BE SET AT A CONVENIENT LOCATION ADJACENT TO THE BUILDING AND TO BE BOTH AUDIO AND VISUAL. 4. ELECTRICAL PERMIT REQUIRED JOB # 16-0107 SITE & SEWAGE REPAIR PLAN #88 81l?EEZ)1 POINT ROAD IN S. YARMOUTH, MASS DATE: MAY 18, 2016 REV: SEPT. 23, 2016 OWNER/APPLICANT: RICHARD J. GENTILE 88 BREEZY POINT ROAD S. YARMOUTH, 02664 (603) 930-6857 SHEET 3 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM DATUM: VERTICAL DATUM: NAVD-1988 BENCH MARK USED: CENTER OF ELEVATION GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A ' MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE, 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. DRAIN MANHOLE IN STREET 4.79 NAVD-1988 VARIANCES APPROVED TITLE 5: 1. 15.211 (1) TO ALLOW THE LEACHING FIELD TO BE 0.5' FROM THE STREET PROPERTY LINE. 2. 15.211 (1) TO ALLOW THE LEACHING FIELD TO BE 10' FROM CRAWL SPACE FOUNDATION IN LIEU OF 20'. 3. 15.211 (1) TO ALLOW THE SEPTIC TANK TO BE REPLACED IN ITS CURRENT LOCATION AT 6' FROM THE CELLAR WALL IN LIEU OF 10'. 4. 15.212 (1) TO ALLOW 4' OF SEPARATION TO GROUNDWATER IN LIEU OF 5' 5. 15.255 (2) TO ALLOW THE LEACHING AREA TO BE 2' FROM THE FRONT WALL IN LIEU OF 5'. 6. 15.255 (5) TO ALLOW A REDUCTION TO 2' FROM 5' IN THE FRONT LEACHING AREA ALLOWING THE EXTERIOR OVERDIG TO BE 15.5' WIDE IN LIEU OF 18.5'. TOWN OF YARMOUTH: 1. (SECTION 3.7) TO ALLOW THE LEACHING AREA TO BE 57' FROM THE WETLANDS IN LIEU OF 100'. DTH #1 ib INDICATES DEEP TEST HOLE INDICATES P-1 22" PERC TEST SYSTEM DESIGN DESIGN FLOW 3 BEDROOMS AT110 GPB/D 3-I0 GPD REQUIRED SEPTIC TANK 330 x 2__ _ __660 GAL. EX. SEPTIC TANK PROV. = _100 --GAL. PROPOSED PUMP CHAMBER. = _ 6$O --GAL.** SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE -___MIN./INCH LONG TERM APPL. RATE-2.74_GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 330 _ 0.74 SF/GPD = 446 S.F. MIN. REQ. USING 24 QUIK-4 INFILTRATORS CHAMBERS LOW PROFILE UNITS AND NO STONE AROUND 4.73 SF / LF X (3 x 32) = 454 S.F 484 x 0.74 G/SF = 336 GPD 336 GPD PROV > 330 GPD REQ. = 6 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) ** 650 GALLON PUMP CHAMBER IS SPECIAL ORDER 34" INDICATES ADJ. GROUNDWATER 34" OBSERVED GROUNDWATER GROUNDWATER ADJUSTMENT TIDAL ELEVATION 1.6 B.O.H. AMY VON HONE SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. (KEVIN) ELLIS BROTHERS SOIL TYPE: 1 PERC RATE: <2 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN D.T.H. #1 ib DATE: 4-21-16 GROUND ELEV. 4.4 ADJ. GROUNDWATER A LOAMY SAND EL.=3.7 1OYR 4/3 8" B 22" LOAMY SAND 1OYR 5/6 EL.=1.6 34" C MEDIUM SAND 2.5Y 6/6 EL.=( -3.6 96" TIDAL ELEVATION 1.6 B.O.H. AMY VON HONE SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. (KEVIN) ELLIS BROTHERS SOIL TYPE: 1 PERC RATE: <2 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN