Loading...
HomeMy WebLinkAboutReview Checklist �- i6 --�� t TOWN OF YARMOUTH ~ SEWAGE PLAN REVIEW CHECKLIST , Location: A.M. /��`" Lot� Zone of Contribution: In Out Acreag� Commercial: Residenti ' ' Street: ` ' Village: Floor Plan: �� #Bedrooms: � ' Owner: Installer: G'� ' Address: Phone.��r� �" ���� � Phone: Builder: Engineer: �� G�'�� : Address: Phone: � �-- Phone: � � �i��Cs4 � �,,��" N/A YES NO l.Re uired#of copies received 2.Date of soils exam and ercolation test not older than 2 years " 3.4-5 ft of naturall occurrin ervious material, above water table �.,.,_......- 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic com onents Var.: 6.Benchmark indicated and shown-NGVD if near wetlands ' 7. S tic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking welU25 ft irri ation well Var.: 1 l.Tank/leachin minimum 10 ft from ro erty line Var.: �:,�--'' 12. S stem meets all other setback r uirements Var.: - 13.Uses adjustment for maximum high oundwater Var.: 14.Leachin set 4-5 ft above ad'.water or bottom of test hole Var.: �.� 15. System not in to or subsoil(A,B horizons)or 5'removal " 16.Pro osed contours are suitable 17. S stem meets slo e r irements-min. 1/8", '/a" referred �.--- 18. System meets breakout r uirements PVC liner: Wall: 19. S ecified tee sizes are roper, gas baffle on outlet tee �--� 20. Sewa e is under 10,000 gpd for arcel �---'"' 21.No bage dis osal - ' 22. S stem ad uatel sized for its intended use " 23.Minimum 6"stone or compacted below tank and dbox � - ' y 24.Manhole covers within 6"of grade,pum cha.mber cover to grade �,._,..�' 25.Inspection ort on plastic chambers/leach field �� 26.Electrica.l ermit for um chamber/S arate meter for du lexes 27.Pum system-2" line,weep hole,check valve,tee in dbo�pump size .�--^ 28. Se tic tank/pump chamber to be factory waterproofed � 29.Vent rovided if leaching below 3 feet,under driveway/ arking �' 30.Buoyancy calculations for tank/pump cha.mber 31.En � eer to ins ect and cert' soils: wall: commercial:, - 32.Engineer/Re 'stered Sanitaxian and Land Surveyor stam s/signature � 33.H-201oadin is subject to vehicular traffic, groundwater ; 34. Title V A lication and ermit fee, insta.11er si ature �.---�' 35.Foundation footin min. 2 feet above ad'usted ground water for new house -�'"' 36.Deed Restriction re uired max. #bedrooms: ma�L. flow: d --�--` 37. Check area lots for oundwater/Label groundwater in Assessor's Ma f'"`" ✓ .� � � Plan reviewed by: (G�-�t. 6/03/03