HomeMy WebLinkAboutReview Checklist r��� ���
TOWN OF YARMOUTH '
SEWAGE PLAN REVIEW CHECKLIST � '
Location: A.M.� Lot_� Zone of Contribution: In Out_ Acreage �
Commercial: Residential:��
Street: �._��,��,�i'C� i
Village: Floor Plan: #Bedrooms: )��[J^'Y ,
�t
Owner: Insta.11er: '
Address: Phone: '
Phone:
Builder: Engineer: � �'f
Address: Phone: '' �
Phone:
N/A YES NO
1.Required#of copies received
2.Date of soils exam and ercolation test not older than 2 ears
3.4-5 ft of naturall occurrin ervious material, above water table �--�'
4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.:
5.Water line 10 ft from s tic com onents Var.:
6.Benchmark indicated and shown-NGVD if near wetlands c,.��
7. Se tic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leachin minimum 100 ft from wetlands Var.:
10.Lea.chin minimum 150 ft from drinking welU25 ft irrigation well Var.: � '
11.Tank/leaching minimum 10 ft from ro erty line Var.: '
12. S stem meets all other setback r uirements Var.:
13.Uses adjustment for ma�mum hi groundwater Var.: ✓
14.Leaching set 4-5 ft above ad'.water or bottom of test hole Vaz.:
15. System not in to or subsoil(A,B horizons)or 5'removal `./
16.Pro osed contours are suitable
17. S stem meets slo e r uirements-min. 1/8", '/4" eferred
18. System meets breakout re irements PVC liner: Wall:
19. S ecified tee sizes are pro er, gas baffle on outlet tee ;
20. Sewage is under 10,000 d for parcel �/
21.No garbage disposal ��
22. S stem ade uatel sized for its intended use ✓ • '
23.Minimum 6"stone or com acted below tanlc and dbox ✓/
24.Manhole covers within 6"of grade, um cha.mber cover to ade
i25.Ins ection port on lastic chambers/leach field
26.Electrical ermit for um chamber/S arate meter for du lexes
27.Pum s stem-2" line,wee hole,check valve,tee in dbo� ump size
28. Septic tank/ um chamber to be factory waterproofed ..�
29.Vent rovided if leachin below 3 feet,under driveway/ arking ✓
'' 30.Buo ancy calculations for tank/ um chamber
31.En ' eer to ins ect and cert' soils: wa.11: commerciaL• �
32.Engineer/Re 'stered Sanitarian and Land Surveyor stam s/signature
33.H-201oa.ding is sub'ect to vehicular traffic,gtoundwater
34.Title V A lication and ermit fee, installer si ature
35.Founda,tion footin min.2 feet above adjusted ound water for new house
36.Deed Restriction r uired max. #bedrooms: max. flow: d �.
37.Check area lots for groundwater/Label oundwater in sor's Ma
Plan reviewed by: �osioa
�