HomeMy WebLinkAboutReview Checklist I
7,�y-�c '
TOWN OF YARMOUTH ;
- SEWAGE PLAN REV�W CHECKLIST I
;
Location: A.M.� Lot� Zone of Contribution: In Out l/ Acreage �
• Commercial: Residential:�-� �
Street: � �� '� / �
Village: Floor Plan: V #Bedrooms:�� ;
Owner: .y��� Insta ller: � ;
Address: Phone: '
Phone:
Builder: Engineer:
Address: Phone: - � r' %
Phone: -�}e�i�� � �f�°�����
/ �
�
N/A YES NO
1.Re uired#of co ies received t. '
2.Date of soils e�cam and percolation test not older than 2 ears �..�- '
3.4-5 ft of naturall occurrin ervious material,above water table
4.Foundation 2 ft above high int of road H.P.: Fnd: Var.:
5.Water line 10 ft from s tic components Var.: `-�
6.Benchmark indicated and shown-NGVD if near wetlands `.,� '�
7. S tic tank minimum 10 ft from foundation, deck Var.: �-- -' ,
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �
9.Leachin minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking welU25 ft irri tion well Var.: �
11.Tank/leachin minimum 10 ft from roperty line Var.: �- i
12. S stem meets all other setback r uirements Var.: '
13.Uses ad'ustment for maximum hi groundwater Var.:
14.Leachin set 4-5 ft above ad'.water or bottom of test hole Var.: �...�
15. System not in to or subsoil(A,B horizons)or 5'removal `„�� '
16.Pro osed contours are suitable 1,--�� '
17. S stem meets slo e r uirements-min. 1/8", 1/4" referred ✓ I
18. S stem meets breakout r uirements PVC liner: Wall:
19. Specified tee sizes are pro er, as baffle on outlet tee !
20. Sewa e is under 10,000 gpd for arcel �
21.No arbage dis osal
22. S stem ad uatel sized for its intended use �
23.Minimum 6"stone or com acted below tank and dbox �_�
24.Manhole covers within 6"of grade, um chamber cover to grade ��--
25.Ins ection ort on lastic chambers/leach field
26.Electrical ermit for um chamber/S arate meter for du lexes .:---�'
27.Pum system-2" line,wee hole,check valve,tee in dbox, um size ��� I
28. Septic tank/ ump chamber to be factory wat roofed �
29.Vent rovided if leaching below 3 fe�t,under driveway/ arkin '
30.Buo ancy calculations for tank/pum chamber
31.En ' eer to ins ect and cert' soils: wall: commercial:
32.En ' eer/Registered Sanitarian and Land Surve or stam s/si ature
33.H-20 loadin is sub'ect to vehicular traffic, groundwater
34.Title V A lication and ermit fee, insta.11er signature
35.Foundation footing min. 2 feet above ad'usted ound water for new house
36.Deed Restriction r uired max. #bedrooms: ma�c. flow: d
37.Check area lots for oundwater/Label groundwater in Assessor's Ma
Plan reviewed by: �i` �ro3ioa