Loading...
HomeMy WebLinkAboutEngineered Plan - 2016SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE EL. 12.1 ' FILTER FABRIC OVER STONE MINIMUM .75' OF COVER OVER PRECAST I 1)q• ci nor or PRECAST H-10 RISERS (TYP.) 2'0 12.1' 4"OSCH40 PVC 10" EXISTING 14" PIPES LEVEL 1ST 2' TEE SEPTIC TANK** TEE 10.7* GAS BAFFLE 000000000000 '9 00 9.68' 9.51' ' WATERTEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 (21) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE. LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE ( 6 % SLOPE) (-L-% SLOPE) FOUNDATION- EXIST. SEPTIC TANK 17' D' BOX 6' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE LEGEN D 99- EXISTING CONTOUR . X 99.1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 0" 11' TEST HOLE I %. SLOPE OF GROUND CQ-) UTILITY POLE y o FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS. AMY VON HONE, RS DATE: 10/26/2016 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ,S ELEV. 4 0" 11' 1• A LS 1OYR 3/3 18" B LS 30" 1 OYR 5/6 8.5' C PERC FS 2.5YR 7/4 DECK FAMILY ROOM KITCHEN LIVING ROOM PORCH FLOOR PLAN NOT TO SCALE G -W ADJ. DATA: WELL: M I W 29 ZONE: B ADJ: 4.1' OCTOBER 2016 TH 16 H-20 HIGH CAPACITY INFILTRATORS EACH UNIT: 6.25' X 2.83 X 16" HIGH OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 25' X 11.3' (NO STONE PROPOSED) LEACHING FACILITY 4' USE HALF OF GROUNDWATER ADJUSTMENT ADJUSTED GROUNDWATER EL. 4.55' 108" 20 y4���..;U"�1. GROUNDWATER ENCOUNTERED AT 102" EL 2.5' �P DCE #16-34� ' t`i`ts Scale: 1"= 20' 0 10 20 30 40 50 FEET NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING AND VERIFYING IGSAFE THE LOCATION OF ALL233UN0 UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± 11. ANY UNSUITABLE MATERIAL ENCOUNTERED ASSESSORS MAP 32 PARCEL 196 SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA -FLOOD ZONE AE 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (EL 11) AS SHOWN OWCOMMUNITY COMMUNITY AND REMOVED OR PUMPED AND FILLED WITH CLEAN PANEL #25001 CO588J DATED 7/16/2014 SAND. VARIANCES MAXIMUM FEASIBLE COMPLIANCE- SYSTEM DESIGN. LOCAL UPGRADE APPROVAL 310 CMR 15.405(1)(h): GARBAGE DISPOSER IS NOT ALLOWED REDUCTION IN SEPARATION OF SAS TO DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD ADJ. G.W. FROM 5' TO 4.0' USE A 330 GPD DESIGN FLOW YARMOUTH HEALTH DEPT. POLICY: REQUEST USING HALF THE SEPTIC TANK: 330 GPD (2) = 660 ADJUSTMENT TO PREVENT PUMP CRAM -BER- 4"dSTALLATIOId - -- - RE -ISE EXISTING_ SEPTIC _TANK** LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) H-20 HIGH CAPACITY UNITS IN ;FIELD CONFIGURATION OF 4 ROWS OF 14 UNITS Permit valid for REPAIR t)I' SH 1''I !C SYS1 EM ONLY, doe to State and I.«��:il septic variances. 16 UNITS x 29.5 SF = 472 SF > 445.9 SF Board of llealth review :end approeal i, required for 472 SF (0.74) = 349 GPD (OK) any fu re additions/ rew,, ations/alterations to seg+age facilities an structures/dwelling. Yarmouth Health Department APPROVIM/ - _ i - !G`, G DATE APPROVED DATE BOARD OF HEALTH M A m� bate TITLE 5 SITE PLAN OF #22 IROQUOIS BLVD 1VEDWEST YARMOUTH, MA DEC 0 5 2016 PREPARED FOR NrAITI-I nFPT JOHN ARANCIO DATE: NOV. 8, 2016 N or Mass ���D OF Mgoff 508-362-4541 ssgc fax 508-362-9880 q� oma' DANIEL '� 4NIELA. yes A G�� downcope.com C CIVIL (n A N° o ao down cove enfineerh7 %nC, CIVIL 02 Q civil engineers 'STE N�'�� !q OSUR `-- land surveyors N - sw 939 Main Street ( R to 6A) DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 16-341 ,S Route eQi�• �'` �o• e Locus 1• 0�' o N 0 Qt\cgG�o� e 0 Lewis Lewis Pond Bay R°d antucket power Sound 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING AND VERIFYING IGSAFE THE LOCATION OF ALL233UN0 UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± 11. ANY UNSUITABLE MATERIAL ENCOUNTERED ASSESSORS MAP 32 PARCEL 196 SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA -FLOOD ZONE AE 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (EL 11) AS SHOWN OWCOMMUNITY COMMUNITY AND REMOVED OR PUMPED AND FILLED WITH CLEAN PANEL #25001 CO588J DATED 7/16/2014 SAND. VARIANCES MAXIMUM FEASIBLE COMPLIANCE- SYSTEM DESIGN. LOCAL UPGRADE APPROVAL 310 CMR 15.405(1)(h): GARBAGE DISPOSER IS NOT ALLOWED REDUCTION IN SEPARATION OF SAS TO DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD ADJ. G.W. FROM 5' TO 4.0' USE A 330 GPD DESIGN FLOW YARMOUTH HEALTH DEPT. POLICY: REQUEST USING HALF THE SEPTIC TANK: 330 GPD (2) = 660 ADJUSTMENT TO PREVENT PUMP CRAM -BER- 4"dSTALLATIOId - -- - RE -ISE EXISTING_ SEPTIC _TANK** LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) H-20 HIGH CAPACITY UNITS IN ;FIELD CONFIGURATION OF 4 ROWS OF 14 UNITS Permit valid for REPAIR t)I' SH 1''I !C SYS1 EM ONLY, doe to State and I.«��:il septic variances. 16 UNITS x 29.5 SF = 472 SF > 445.9 SF Board of llealth review :end approeal i, required for 472 SF (0.74) = 349 GPD (OK) any fu re additions/ rew,, ations/alterations to seg+age facilities an structures/dwelling. Yarmouth Health Department APPROVIM/ - _ i - !G`, G DATE APPROVED DATE BOARD OF HEALTH M A m� bate TITLE 5 SITE PLAN OF #22 IROQUOIS BLVD 1VEDWEST YARMOUTH, MA DEC 0 5 2016 PREPARED FOR NrAITI-I nFPT JOHN ARANCIO DATE: NOV. 8, 2016 N or Mass ���D OF Mgoff 508-362-4541 ssgc fax 508-362-9880 q� oma' DANIEL '� 4NIELA. yes A G�� downcope.com C CIVIL (n A N° o ao down cove enfineerh7 %nC, CIVIL 02 Q civil engineers 'STE N�'�� !q OSUR `-- land surveyors N - sw 939 Main Street ( R to 6A) DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 16-341