HomeMy WebLinkAboutReview Checklist ��� � ��
TOWN OF YARMOUTH
' SEWAGE PLAN REVIEW CHECKLIST
. Location: A.M.� Lot '`� Zone of Contribution: In Out_ creage�_
� Commercial: Residential:
Street: � '
Village: Floor Plan: � #Bedrooms: �
Owner: ,.��:��%2�°-t��' Installer: /'�
Address � Phone: � � � �
Phone: � ��/';� �� �G%f t=��;�5_
Builder: Engineer: �� �' �
Address: Phone: � � "
Phone: ��.r� �' , .�� � �'� �>
/ YES NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years i,._�--`
3.4-5 ft of naturall occurrin ervious material, above water table
4.Foundation 2 ft above high oint of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic com onents Var.:
6.Benchmark indicated and shown-NGVD if near wetlands �„/
7. Se tic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking welU25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.:
12. S stem meets all other setback re uirements Var.: t,,..i
13.Uses adjustment for maximum high groundwater Var.:
14.Leaching set 4-5 ft above adj.water or botto f test hot Var.: '-
15. System not in top or subsoil(A,B horizons) 5' re 1�
16.Pro osed contours are suitable
17. S stem meets slo e re uirements-min. 1/8", 1/4" referred
18. System meets breakout re uirements PVC liner: Wall: ;..,.......-�'
19. Spec�ed tee sizes are proper, gas baffle on outlet tee :._,,,_.�
20. Sewage is under 10,000 gpd for arcel
. 21.No garbage dis osal -
22. S stem ade uatel sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox
' 24.Manhole covers within 6"of grade,pum chamber cover to ade `�---j`
25. Inspection ort on plastic chambers/leach field
26.Electrical ermit for um chamber/Se arate meter for du lexes _----
27.Pump system-2" line,weep hole,check valve,tee in dboar,pump size
28. Septic tank/pump chamber to be factory waterproofed
29.Vent rovided if leaching below 3 feet, under driveway/parking �
30. Buoyancy calculations for tank/pum chamber
31. En ' eer to ins ect and cert' soils: wall: commercial: _._.�-�
32.Engineer/Re 'stered Sanitarian and Land Surveyor stam s/si ature �------'
33.H-201oading is subject to vehicular traffic, groundwater --=
34.Title V A plication and permit fee, insta.11er signature ✓
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction r uired max. #bedrooms: max. flow: d
37. Check area lots for groundwater/Label oundwater in Assessor's Map
Plan reviewed by: �,�+(�� 6/03/03
`��