Loading...
HomeMy WebLinkAboutEngineered Plan - 2016N SITE PLAN SCALE: 1 =20 BENCH MARK ON CORNER OF CONCRETE APRON ELEV.-50.00- (ASSUMED) PO •., 49A7' O 4 PROPOSED SAS ` !' 2-20'X 10.8'X 11" �''• leaching trenches using H-20 High Capacityy INFILTRATOR ° chambers wi}h 4' of stone rA° 48.21• INLET Cf.161➢ �vX 48.68' X cep; 9 1 O J /? 4712' STS FFT 3-20' DIAM. ACCESS MANHOLES "•LOT 14 A=12,100)-_'SQ.FT., STEEL REINFORCED PRECAST CONCRETE PLAN VIEW -10' min. from- house rom-.house to septic tank Existing House FF ELEV.-51.70' MMainn�Setver hamr ceimsdpods to be S _ ria int.dt;l&. i a dim �t0.02 /}L cellar 8 X 47.e2' be 'f26 to n�R�ti RQ k'ater h le INLET -r CCESS COVERS FOR THE SEPTIC TANK 5' -r Nouns sr High Capacity Trench Detail (Not to Scale) 3/4' to 1 1/2' double -washed crushed stone regets-om cover 0 or- Local Code SITE v, J LOCUS NO SCALE --PERK TEST & SOIL EVALUATION GENERAL NOTES Date of Perc. Test & Soil Eval.: August 24, 2016 1. ADDRESS: 20 NORTH ROAD, YARMOUTH Test Performed A Glen E. Hone, R. . R.S.2. ASSESSORS NUMBER: MAP 30 PARCEL 178 WITNESSED BY. Amy Von Hone, R.S. 3. DEVELOPER'S LOT. LOT 14 EXCAVATOR: Scott Campbell, Cardinal Construction 4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM AN PERK RATE: LESS THAN 2 MPI ON THE GROUND INSTRUMENT SURVEY. aleIIIIIIIIIIII's melte 9. All existing inverts and site conditions shall be verified by contractor. 10. The Hi Cap Infiltrators shall be installed according to the DEP General Use Approval letter and the infiltrator Installation Gukielines. 3-20' REMOVABLE COVERS 11. The existing cesspools shall be pumped and filled with dean sand. 12. Plumbing exiting to exisitng cesspools shall be connected to proposed septic system ` via Internal plumbing relocation. 4' f c •L , �. 13. Reserve area with 2' effective depth is Title V compliant for a 3 bedroom dwelling. 3 min. clearance sf1.ET . ALL 01I Tres nnr Im min. Y min. inlet to outlet e. rain. SIX LEunoF Rax LII 6E t1' a "CIRM oowe a1r lE1eL FOR AT tFA4r 2 R 10 min. Liquid level OUTLET lc) V.: R _ r 01I 1� j; s O_ laoaxom •. 5' -r W em 1r eecT THE A c= 4 > CV - 0.s` anus, i OUTLET DISTRIBUTION BOX AND LEACHING COMPONENT E g r 4'-0" min. 00 • r r SHALL BE WITHIN 6" OF FINISHED GRADE. o$ oe.Ba1Ai .4 Liquid depth ' U N J 1sr k. ` •r INSTALL TUF-TiTE GAS BAFFLE OR EQUAL ;•� W w PLAN -SECTION CROSS-SECTION ON ALL OUTLET TEE ENDS W (.") _ 5 HOLE H-20 DISTRIBUTION BOX 10La' • 5' -8" NOT To SCALE - CROSS --SECTION END-SECTION,��_34,�s, • Boa V � PROPOSED SEPTIC SYSTEM REPAIR TYPICAL 1500 GALLON H-10 SEPTIC TANK P,���� •sex PREPI MR NOT TO SCALE' Ap TTM ° p CARDINAL CONSTRUCTION C. r" AT LEGEND Q Cf BTA 20 NORTH ROAD SYSTEM PROFILEO 5. TOWN WATER IS PROVIDED TO SITE & SURROUNDING PROPERTIES. EXtsm CESSPOOLS TO BE PUMPED AND REMOVED , r YARMOUTH, MA Test Hole Not t0 6. REFERENCE PLAN: PLAN BOOK 66 PAGE 111 0001 1500 GAL H-10 SEPTIC TANK No. 1 °(�OFMA 7. NO WETLANDS ARE LOCATED WITHIN 150 FEET OF SAS. *NOTE: ALL PIPES ARE TO BE 4" DIA. SCHEDULE 40 P.V.C. x104.46 DENOTES EXISTING 5USE OLE �la T. Box observation pr 3�bdo�sr grade 8. NO POTABLE WELLS ARE LOCATED WITHIN 150 FEET OF SAS. � �`' r. ss9� CILE GLEN E. H A R R I N GTO N , R.S. £XRS7M GR" ELEV.=50 t OR EQUAL LS IELEV. EXISTING CONTOUR 9. THE SITE IS NOT LOCATED WITHIN A ZONE II. g LEDA ROSE LANE Tank �,,.m shall be eittdrl 6' of finished grads s-am•/1L D -Box *hall be within 8' findahed grade L.wl �' r " DEEP TEST HOLE PERK TEST 10. UTILITIES WERE LOCATED BY DIGSAFE. PROPOSED SEPTIC 1.500 GAL a°+' R 5' Invert V#I-W W- „- 10VI,,pid TEL: 774-238-1813 DEPTH: 26-44" Design Calculations , I. Leochacility existing water line q/V/TARS _' er EO BEGIN SOAK: O MINUTES o'_D FBottom of Elan.=44.64• GAS Approx. location 'e` m tona/e END SOAK: 8 MINUTES Number of Bedrooms: 3 existing gas service SCALE: 1 "=20' DRAWN BY: GEH 29" I§AC LEACHING FIELD H. #1 elev.=38.56' Garbage Grinder. NO, GRINDER NOT ALLOWED WITH THIS DESIGN Observation Port DATUM: ASSUMED i FILE: CampbellNorth SHEET 1 OF 1 c, e- �,�4._„�. STONE TIME: 8 MIN.= UNABLE TO SOAK, Septic Tank Capacity Required: 330 gpd X 2009E = 660 gpd. 1,500 -GAL MIN. REO'D. e+ed. em,d - USE <2 MPI FOR DESIGN Septic Tank Provided: 1,500 -GAL 60' 1 106/6 .06' Leaching Capacity Required: 330 Gal./Day Leaching Area Required: 330 Gal./(0.74 Gol./Sq.Ft.)-446 Sq.Ft. C2 Proposed Leaching Area Provided: SIDES: 20' X 0.92' X 2 =36.8 SF 1e1111. ii° ENDS: 10.8' X 0.92' X 2=19.9 SF ssrsp BOTTOM: 20' X 10.8' =216 SF 12C- TOTAL=272.7 SF NO GROUNDWATER ENCOUNTERED X 2 TRENCHES 545.4 SF > 446 SF Total Leaching Capacity Provided: 403 gpd > 330 gpd. req'd. Soil Evaluation Certification I ceitify that on October, 1995, I have passed the soil evaluator CONSTRUCTION NOTES examination approved by the DEP and that the analysis was performed by me consistent with the requir tr ining, xpe 8 rid erieWDd t. Contractor is responsible for Digsafe notification and protection of all underground utilities and pipes. in 310 CMR 15.017. 2. me septic tank / q distribution box shall be set__,_ -'level- ono of 3l4 -11 2` -stone.Glen E. Herrin on, R.S. 3. Backfill should be clean sand or gravel with no stones over 3' in size. 4. This system is subject to inspection during installation by Glen E. Harrington, R.S. 5. The contractor shall install this system in aaaordance Y�Irf7D®ai�t �Ie�lgh I)epti'6EE]elIlli n with Title V of the Massachuestts Environmental Code and the Regulations of the Town of YARMOUTH. GVEIInfiltrator 6. Provide an Wiggin Precast H-10 1,500 gal septic tank, DB -5 H-20 D -Box and 4 H-20 Hi Cap chambers or equal _ 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. L111e 8. Install teas baffle or equal on septic tank outlet tee end. melte 9. All existing inverts and site conditions shall be verified by contractor. 10. The Hi Cap Infiltrators shall be installed according to the DEP General Use Approval letter and the infiltrator Installation Gukielines. 3-20' REMOVABLE COVERS 11. The existing cesspools shall be pumped and filled with dean sand. 12. Plumbing exiting to exisitng cesspools shall be connected to proposed septic system ` via Internal plumbing relocation. 4' f c •L , �. 13. Reserve area with 2' effective depth is Title V compliant for a 3 bedroom dwelling. 3 min. clearance sf1.ET . ALL 01I Tres nnr Im min. Y min. inlet to outlet e. rain. SIX LEunoF Rax LII 6E t1' a "CIRM oowe a1r lE1eL FOR AT tFA4r 2 R 10 min. Liquid level OUTLET lc) V.: R _ r 01I 1� j; s O_ laoaxom •. 5' -r W em 1r eecT THE A c= 4 > CV - 0.s` anus, i OUTLET DISTRIBUTION BOX AND LEACHING COMPONENT E g r 4'-0" min. 00 • r r SHALL BE WITHIN 6" OF FINISHED GRADE. o$ oe.Ba1Ai .4 Liquid depth ' U N J 1sr k. ` •r INSTALL TUF-TiTE GAS BAFFLE OR EQUAL ;•� W w PLAN -SECTION CROSS-SECTION ON ALL OUTLET TEE ENDS W (.") _ 5 HOLE H-20 DISTRIBUTION BOX 10La' • 5' -8" NOT To SCALE - CROSS --SECTION END-SECTION,��_34,�s, • Boa V � PROPOSED SEPTIC SYSTEM REPAIR TYPICAL 1500 GALLON H-10 SEPTIC TANK P,���� •sex PREPI MR NOT TO SCALE' Ap TTM ° p CARDINAL CONSTRUCTION C. r" AT LEGEND Q Cf BTA 20 NORTH ROAD Y - 1 -b SYSTEM PROFILEO EXtsm CESSPOOLS TO BE PUMPED AND REMOVED , r YARMOUTH, MA Not t0 ScalePROPOSED 0001 1500 GAL H-10 SEPTIC TANK OWNERS: RICHARD F. HENDERSON. JR. & LINDSAY D. STRANGER °(�OFMA PREPARED BY: *NOTE: ALL PIPES ARE TO BE 4" DIA. SCHEDULE 40 P.V.C. x104.46 DENOTES EXISTING 5USE OLE �la T. Box observation pr 3�bdo�sr grade SPOT GRADE � �`' r. ss9� CILE GLEN E. H A R R I N GTO N , R.S. £XRS7M GR" ELEV.=50 t OR EQUAL EideNns Grade OeK�4s t Fin! waft over .yr ........... 495 EXISTING CONTOUR G „�� � IG :j � g LEDA ROSE LANE Tank �,,.m shall be eittdrl 6' of finished grads s-am•/1L D -Box *hall be within 8' findahed grade L.wl �' r 2:mlo. oe�=�•� ,� DEEP TEST HOLE Q 'HA GTON, � MARSTONS MILLS, MA 02648 PROPOSED SEPTIC 1.500 GAL a°+' R 5' Invert V#I-W W- Approx. location o.107 0 0 TEL: 774-238-1813 H-10 GAS B°R _ , I. Leochacility existing water line q/V/TARS _' EMAIL: gharr88®hotmail.com EO o'_D FBottom of Elan.=44.64• GAS Approx. location 'e` OF 3le-11/Y STONE 't (s Min. required) existing gas service SCALE: 1 "=20' DRAWN BY: GEH 18 SEP 2016 LEACHING FIELD H. #1 elev.=38.56' O.P. Observation Port DATUM: ASSUMED i FILE: CampbellNorth SHEET 1 OF 1 e- �,�4._„�. STONE Y - 1 -b