HomeMy WebLinkAbout261 Whites Path DetailsBASED ON BRYANT U SHALL BE PROVIDED WITH ECONOMIZER CONTROLS. 20 SHALL BE PROVIDED WITH 14" TALL ROOF CURB. EXISTING RTUs — CARRIER EXISTING RTUs TO BE REBALANCED TO THE SPECIFIED CFMs AS SHOWN. 30. EXISTING RTU -8 TO BE SWAPPED WITH RTU -4 EXHAUST FAN SCHEDULE ITEM MODEL TYPE SERVICE CFM ENP RPM HP V PH HZ REMARKS RR -2 PDDR LAY—IN 2424 8x8 — RR -3 PDDR LAY—IN 2424 CUH-1 CWH3407F EF -1 SP -13110 CEILING MOUNTED BREAK ROOM 100 0.375 950 80(W) 115 1 60 20. EF -2 G-090—VGROOF MOUNTED BATHROOMS 580 0.5 1725 1/10 115 1 60 10. EF -3 G-065—VGROOF MOUNTED ART ROOM 155 0.375 1725 1/10 115 1 60 20. EF -4 CUE-085—VGROOF MOUNTED KITCHEN 500 0.375 1725 1/10 115 1 60 20. EF -5 SP -13110 CEILING MOUNTED COPY ROOM 75 0.375 950 80(W) 115 1 60 10 ����e��eeee■■ease■■■■ems ����ee��eee■■ease■�■■ems BASED ON BRYANT U SHALL BE PROVIDED WITH ECONOMIZER CONTROLS. 20 SHALL BE PROVIDED WITH 14" TALL ROOF CURB. EXISTING RTUs — CARRIER EXISTING RTUs TO BE REBALANCED TO THE SPECIFIED CFMs AS SHOWN. 30. EXISTING RTU -8 TO BE SWAPPED WITH RTU -4 EXHAUST FAN SCHEDULE ITEM MODEL TYPE SERVICE CFM ENP RPM HP V PH HZ REMARKS RR -2 PDDR LAY—IN 2424 8x8 — RR -3 PDDR LAY—IN 2424 CUH-1 CWH3407F EF -1 SP -13110 CEILING MOUNTED BREAK ROOM 100 0.375 950 80(W) 115 1 60 20. EF -2 G-090—VGROOF MOUNTED BATHROOMS 580 0.5 1725 1/10 115 1 60 10. EF -3 G-065—VGROOF MOUNTED ART ROOM 155 0.375 1725 1/10 115 1 60 20. EF -4 CUE-085—VGROOF MOUNTED KITCHEN 500 0.375 1725 1/10 115 1 60 20. EF -5 SP -13110 CEILING MOUNTED COPY ROOM 75 0.375 950 80(W) 115 1 60 10 BASED ON GREENHECK EXHAUST FAN SHALL RUN CONTINUOUSLY IN OCCUPIED MODE. PROVIDE TIME CLOCK. 20 EXHAUST FAN SHALL BE CONTROLLED BY A WALL MOUNTED SWITCH. CABINET UNIT HEATER SCHEDULE ITEM N0. MODEL SERVICE TYPE WATTS MBH AMPS V PH HZ REMARKS — RR -2 PDDR LAY—IN 2424 8x8 — RR -3 PDDR LAY—IN 2424 CUH-1 CWH3407F VESTIBULE WALL MOUNTED 4000/2000 13.6/6.8 14.05/7.2 277 1 60 Q BASED ON QMARK10 COLOR SHALL BE DETERMINED BY OWNER Q PROVIDE DEEP SURFACE MOUNTING FRAME. STRUCTURE DUCT SUPPORT PER SMACNA DUCT SUPPORTS SHOULD WRAP 1" AROUND BOTTOM OF DUCT per— VOLUME DAMPER SHEET METAL SCREW TYPICAL PROVIDE SUPPORT FOR 1 � REGISTER OR GRILLE �— FINISHED CEILING EXHAUST GRILLE OR REGISTER TYPICAL RETURN/EXHAUST GRILLE OR REGISTER DETAIL 2" ACOUSTICAL INSULATION APPLIED TO INSIDE OF CURE WITH WELD CLIPS BY HVAC CONTRACTOR. ROOF CURB WITH WOOD S5 SUPPLIED BY MANUFACTURE 2" ACOUSTICAL INSULATION INSTALLED ON TOP OF THE ROOF DECK BY HVAC CONTRACTOR. RIGID INSULATION BY G.C. (SAME AS ROOF INSULATION NO SCALE STRUCTURE DUCTWORK HANGER SQUARE TO ROUND DIFFUSER ADAPTER CEILING DIFFUSER RETURN REGISTER SCHEDULE ITEM NO. MODEL TYPE SIZE NECK SIZE REMARKS RR -1 PDDR LAY—IN 2424 8"0 — RR -2 PDDR LAY—IN 2424 8x8 — RR -3 PDDR LAY—IN 2424 10"0 — RR -4 PDDR LAY—IN 2424 10x10 — RR -5 PDDR LAY—IN 2424 12"0 — RR -6 PDDR LAY—IN 2424 12x12 — RR -7 PDDR LAY—IN 2424 14"0 — RR -8 PDDR LAY—IN 2424 1404 — RR -9 PDDR LAY—IN 2424 15x15 — RR -10 PDDR LAY—IN 20x20 1Ox10 — BASED ON PRICE NOTE: PROVIDE DUCT TRANSITIONS TO REGISTERS AS REQUIRED. HEAT PUMP INDOOR UNIT SCHEDULE ITEMMODELSUPPLY N0. MODEL FAN COOLING COIL TOT. MBH HEATING COIL TOT. MBH WEIGHT (LBS) REMARKS WATTS MCA RA QTY FLA V PH HZ MCA M0CP AC -1 PKA—A18HA7 320-370-425 30 1.0 0.33 18 19 29 @@Q(j)R41 OA BASED ON MITSUBISHI 1Q. POWER PROVIDED BY ASSOCIATED ACCU. ® PROVIDE LOW AMBIENT CONTROLS UP TO 0' F 0 PROVIDE A WALL MOUNTED WIRED THERMOSTAT Q PROVIDE CONDENSATE PUMP. HEAT PUMP OUTDOOR UNIT SCHEDULE ITEM N0. MODEL SERVICE CONDENSER FAN NOMINAL TONS COMP. #1 RLA ELECTRICAL REMARKS QTY FLA V PH HZ MCA M0CP ACCU-1 PUZ—A18NKA7 IT ROOM 1 0.5 1.5 7 208 1 60 11 28 OQ2 R410A BASED ON MITSUBISHI — COMPRESSOR w/DC—INVERTER—DRIVEN TWIN ROTARY10 PROVIDE LOW AMBIENT CONTROLS TO 0'F. 02 PROVIDE SEACOAST PROTECTION SPRAY. SUPPLY AIR DUCT VOLUME DAMPER INSULATED WITHIN FITTING FLEXIBLE DUCT (MAX. 6'-0" LENGTH) - - --------------------------- - - - - FINISHED CEILING CEILING DIFFUSER CONNECTION DETAIL 'AIR HANDLING UNIT ATE DRAIN DN TO UNIT SCHEDULE '—TRAP FLASHING BY G.C. MEMBRANE 'IP BY G.C. INSULATION ROOFTOP UNIT CURB MOUNTING DETAIL NO SCALE NO SCALE FLASHIN FLASH I N BUILT U SOLDER ALL BOTTOM & CORNER SEAMS 4" UP EACH SIDE. T FAN IRICATED EXHAUST DUCT —— 4" MIN. U P B LAST ROOF EXHAUST FAN DETAIL NO SCALE EXISTING 4"0 EXHAUST DUCT FAN HOUSING WITH DIRECT DRIVE CENTRIFUGAL BLOWER GRILLE SUPPLY DIFFUSER SCHEDULE ITEM NO. MODEL TYPE NECK SIZE BLOW REMARKS CD -1 SMD3P LAY—IN 8"0 2—WAY — CD -2 SMD3P LAY—IN 10"0 2—WAY — CD -3 SMD3P LAY—IN 12"0 3—WAY — CD -4 SMD3P LAY—IN 6"0 4—WAY — CD -51 SMD3P LAY—IN 8"0 4—WAY — CD -6 SMD3P LAY—IN 10"0 4—WAY — CD -7 SMD3P LAY—IN 12"0 4—WAY — CD -8 SMD3P LAY—IN 14"0 4—WAY — BASED ON PRICE NOTE: PROVIDE DUCT TRANSITIONS TO DIFFUSERS & REGISTERS AS REQUIRED. TRANSFER GRILLE SCHEDULE ITEM NO. MODEL TYPE SIZE NECK SIZE REMARKS TG -1 PDDR LAY—IN 2424 8x8 — BASED ON PRICE NOTE: PROVIDE DUCT TRANSITIONS TO REGISTERS AS REQUIRED. EXHAUST REGISTER SCHEDULE ITEM NO. MODEL TYPE SIZE NECK SIZE REMARKS ER -1 PDDR CEIL NC MOUNTED 12x12 6x6 — ER -2 PDDR MOUNNTED 16x16 8x8 — ER -3 PDDR LAY—IN 2424 12x12 — BASED ON PRICE NOTE: PROVIDE DUCT TRANSITIONS TO REGISTERS AS REQUIRED. TYPICAL THREADED STEEL HANGER ROD; SUPPORT FROM BLDG. STRUCTURE. ADJUSTABLE MOUNTING FLANGES CEILING EXHAUST FAN DETAIL NO SCALE LASHING/C( ZASHING B) BUILT UP RC BACKDRAFT """r EXHAUST FAN SOLDER ALL BOTTOM & CORNER SEAMS 4" UP EACH SIDE. —�� 4" MIN. ROOF EXHAUST FAN DETAIL NO SCALE URB LANAUST DUCT LEGEND ROUND AIR DUCT UP ROUND AIR DUCT DOWN SUPPLY AIR DUCT UP SUPPLY AIR DUCT DOWN RETURN/EXHAUST NR DUCT UP RETURN/EXHAUST AIR DUCT DOWN ACOUSTICALLY LINED DUCTWORK (1°) FLEXIBLE CONNECTION �-i CEILING DIFFUSER W/FLEXIBLE CONNECTION VOLUME DAMPER q BACK DRAFT DAMPER FIRE DAMPER w QT THERMOSTAT—ELECTRIC Q REMOTE TEMPERATURE SENSOR RTU ROOF TOP UNIT ACC AIR COOLED CONDENSING UNIT CUH CABINET UNIT HEATER ER EXHAUST REGISTER EF EXHAUST FAN CD CEILING DIFFUSER RR RETURN REGISTER TG TRANSFER GRILLE OU HEAT PUMP OUTDOOR UNIT IU HEAT PUMP INDOOR UNIT RTU ROOF TOP UNIT SA SUPPLY AIR RA RETURN AIR EA EXHAUST AIR OA OUTSIDE AIR PC PLUMBING CONTRACTOR HVAC HEATING, VENTILATING ACCU & AIR CONDITIONING EC ELECTRICAL CONTRACTOR GC GENERAL CONTRACTOR BD BACKDRAFT DAMPER CD CEILING DIFFUSER LD LINEAR DIFFUSER AC AIR CONDITIONING ACCU AIR COOLED CONDENSING UNIT CLG. CEILING RR RETURN REGISTER �-- REFGL REFRIGERANT LIQUID ti— — REFGV — REFRIGERANT VAPOR }—D CONDENSATE DRAIN ` 0 PIPE UP �----� PIPE DOWN PIPE TEE DROP REVISION DATES COMMUNITY CONNECTION INC. STAMP OFFICE BUILDING FIT UP €�3 Yt`s 261 WHITES PATH, S. YARMOUTH, MA Z v _ f� MECHANICAL LEGEND, SCHEDULES & DETAILS $ _� DATE: 03-02-2017 � • � • � �O` - , I � • DRAWING NUMBER SCALE: AS SHOWN w y DRAWN BY: TO ENGINEERING, INC. � _� 645 County Street .Suite 6 CHECKED BY: RA Taunton, MA 02780 PROJECT NO. 17007.00 tel . (508) 884.5094 WWW.CROWLEYENG.COM fax . (508) 884.5099