Loading...
HomeMy WebLinkAboutEngineered Plans - 2017LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT RM ' RM BATH LI V BED DIN RM KIT GAR FLOOR PLAN SCALE: 1"=20' TBM = EL. 29.5 BULKHEAD FOUNDATION 120:29 28.8 EXIST. 1,000G 29.0 SEPTIC TANK 5HED O T 1 10.f . @ � 30.0 (tubes) i (full) AREA=0.27 ARES i N Permit valid for REPAIR OF SE1111C SYSTEM ONLY; due to State and Isocal --)tic variances. Board of Health review and approval is required for any future additions/renw,atious/a iterations to sewage facilities anti/or structures/dwelling. Yarmouth Health Department APPROVED/, 7 of ame Date S 0 to I n _-- t _ WAY 23, r 28.5 -� SERvIc> 22' 11.32' I` 0 vent l 28.1 .12 0 C 79 0 k— \�)-11 Survey by: Weller & Assoc. SOUTH YARMOUTH 'p CAPT. BESS� 7n n n O y a z v SITE '0 CApT. NOBS RD LOCUS MAP LOCUS INFORMATION TITLE REF: BK 14094 PG 269 PARCEL ID: MAP 067 PAR. 187 PROPERTY IS WITHIN A ZONE OF CONTRIBUTION SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 53 CAPTAIN BLOUNT RD. SOUTH YARMOUTH, MA PREPARED FOR MITCHELL ODELL JR. JANUARY 10, 2017 OF�s9�y� o D RR,N ME; R -+ U � E L MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle50gmail.com www.meyerandsons.com SHEET 1 OF 2 J#1744 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS T.O.F. EL.=30.0f SEPTIC TANK PROPOSED D-80 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE F.G. EL.=29.01 F.G. EL.=28.901 /- F.G. EL: 28.701 O S=1% (MIN.) 4"SCH40 /PVC INV.=25.90 9" MIN COYER/ 36" MAX COVER FI = 97 n 48" UOUID - LEVEL I GAS BAFFLE L - 50' L = 1O'(MAX) * S=1% (MIN.) 0 S=IX (MIN.) 4"SCH40 PVC 11 11 4"SCH40 PVC INV.=25.65 \ r.. .. 0' 0`07, ,_.•.•.. _ ....... y INV.=25.15 In& Am Am 1<XISTI_NG. 1.000 GALLON SEPTIC TANK 1 EXIST. SEWER OUTLET I INV.=26.50 DESIGN CRITERIA NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 35.19 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. `F.G. EL: 28.5 (MAX.) INSTALL TWO INSPECTION PORTS (MIN.) i 11 L 61 1 11.3'AL TO INVERT INV.=24.80 1A on PROPOSED D-130 �INV.=24.90 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25'/ROW � DB -5 SOIL ABSORPTION SYSTEM (PROFILE) jH?0) RESTORE VEGETATIVE COVER BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS BREAKOUT=TOP ELEV.= 25.19 INV. ELEV.= 24.80 BOTTOM ELEV.= 23.86 EXISTING SUITABLE 5' MIN. ABOVE BOTTOM OF 2.83' _ MATERIAL T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32' (6.56' PROVIDED) USE 4 ROWS OF 4 -HIGH CAPACITY BOTTOM OF TESTHOLE: EL:17.30 = INFILTRATOR (H20) UNITS W/ ENDCAP-NO STONE SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS ® 110 GPD/BR = 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS I GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (H20) N.T.S. (0.74 GPD/SF) TYPICAL SECTION e.rs. SOIL LOGS DATE: DECEMBER 8, 2017 SOIL EVALUATOR: DARREN M. MEYER, CSE 1614 WITNESS: A. VONHONE, YARMOUTH HEALTH of ,yes Elev. TP- 1 Depth SEPTIC TANK: 330 gpd x 200% = 660 gpd USE EXIST. 1,000G SEPTIC TANK � Sic 28.30 MEYER &SONS, INC. 0" DMM y, PO Box 981 EAST S)NDWICH, Ado 02537 FILLLEACHING CHECKED AREA REQUIRED: (330)/.74 = 445.94 S.F. D REN M. / 27 48 DMM 10" A LOAMY SAND PRIMARY S.A.S. ' No 1 4 "' 26.97B 1OYR 4/1 16" USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE LOAMY 5AND G/$TES 25.72 10YR 5/8 32" C BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) ! TARS ,i ' J P� 0) MSO (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473.0 SF((1 EL. 24.30 2.5Y 6/4 TOTAL AREA = 473 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd 17.30 132" PERC RATE <2 MIN/IN. (-Cl- HORIZON) NO GROUNDWATER OBSERVED • 1. Darren M. Meyer. R.S., CSE, hereby cortify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that 1 have passed the Soil Evol. Exam in October, 1999. GENERAL NOTES: 1• ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.405 (1) (B): 1) A 0.31 Fr. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING TO BE 3.31 Fr (MAX) BELOW GRADE VS REQ'0 3 F7. (H20/VENT PROVIDED) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER SUPPLY. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACHING TO BE PUMPED. CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5 REQUIREMENTS. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING 61 11* INVERT HEIGHT N CAP INFILTRATOR - HI CAPACITY (H2O) CHAMBER I PROPOSED SEPTIC SYSTEM UPGRADE PLAN 53 CAPTAIN BLOUNT ROAD, SOUTH YARMOUTH, MA Prepared for: Mitchell Odell Jr. System Design and Site Pian by: SCALE DRAWN DATE MEYER &SONS, INC. N.T.S. DMM 01/10/17 PO Box 981 EAST S)NDWICH, Ado 02537 REV DATE CHECKED SHEET N0. 508•,a2z922 DMM 2 of 2