HomeMy WebLinkAboutEngineered Plan - 2017.1 SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT To SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 67.0' MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 NOTE: 2" RISERS (TYP.) THICKNESS 2'0 64.94' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE MIN. WALL BLOCKS OR REQUIRED 4"0SCH40 PVC MORTAR ALL PRECAST RISERS H-10 6" MIN. SUMP ' PIPES LEVEL 1ST 2 4' COMPONENTS INV'S EL. 63.03 (NP') 4' EXIST. SPOT ELEV. 12" MIN. INT. DIM. ENDS 198.41 SIDES 64.03' 10" ww 14" EXISTING TEE :; 0000°°°° Q: `.. o..... ° .:. o 0 0 o TEE * ° ° ° ° m®p® 0 aaaa 63.54 Q: .. o o.. o . �L�aO Ct —®®o® °olio°°°o° '00000°o° 2� SEPTIC TANK °°o°o°o°o°o° °°°°°°°° . P40E3®aaoaoo® WATERTEST D BOX o >00000000 0 0 0 0 or El F=31 0 0 0 0 0°0°°0°°°° '0000°°0° FIRE HYDRANT GAS BAFFLE ::: °°�°�?°°�°°� FOR LEVELNESS �' m-000000 EO L 1�U�0�EjEl0F2 Bn0®®E2IQ01�PE 0000000a 63.30' 63.13' '°°0000°° >°0°0°0°o c� a 0°°°°°°° '.o°°°°°°° 61.03' 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. I,. (2) UNITS REQUIRED 00 ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) 0 I (--!—% SLOPE) FOUNDATION— EXIST. SEPTIC TANK 24' — LEGEND- - 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 c � ` TEST HOLE 2� SLOPE OF GROUND UTIUTY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING (1 % SLOPE) 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 SS: AMY VON HONE, RS WITNE DATE: 1/19/17 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. p" 67.0' A LS PORCH 1OYR 3/2 Ffl $" BATH B LS 15" 10YR 5/3 65.8' I BEDROOM G LS 32" 1OYR 5/6 64.3' PERC C2 FS 1OYR 6/8 120" 1 1 57.0' NO GROUNDWATER ENCOUNTERED LICE #17-0/1 LIVING ROOM I KITCHEN I GARAGE FLOOR PLANS NOT TO SCALE ScaIe:1 "= 20' 0 10 20 30 40 50 FEET LEACHING FACILITY CONFIRM NO GROUNDWATER AT TIME OF INSTILLATION DATE NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP NOT TO SCALE ASSESSORS MAP 114 PARCEL 48 SITE IS LOCATED WITHIN A ZONE II 2 BEDROOM DEED RESTRICTION REQUIRED SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 **RE—USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: _ SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) / WITH 4' STONE ALL AROUND`���,� Yarmouth Health Department 4ame AP ROVED Date APPROVED DANIEL A. OJALA, P.E., P.L.S , MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 15 RICHARD ROAD YARMOUTH PORT, MA PREPARED FOR DAVE BARBO DATE: JANUARY 26, 2017 off 508-362-4541 I fax 508-362-9880 downcope.com dow/1 Arpe ea4'ineerin.0, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 17-011 BARBO.DWG a 0 c � z ..c LOCUS c� a 00 LOCUS MAP NOT TO SCALE ASSESSORS MAP 114 PARCEL 48 SITE IS LOCATED WITHIN A ZONE II 2 BEDROOM DEED RESTRICTION REQUIRED SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 **RE—USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: _ SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) / WITH 4' STONE ALL AROUND`���,� Yarmouth Health Department 4ame AP ROVED Date APPROVED DANIEL A. OJALA, P.E., P.L.S , MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 15 RICHARD ROAD YARMOUTH PORT, MA PREPARED FOR DAVE BARBO DATE: JANUARY 26, 2017 off 508-362-4541 I fax 508-362-9880 downcope.com dow/1 Arpe ea4'ineerin.0, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 17-011 BARBO.DWG