HomeMy WebLinkAboutReview Checklist ;
TOWN OF YARMOUTH
�'' �� � -7 SEWAGE PLAN REVIEW CHECKLIST
L,ocation: AM. `,�c� LOT�� Date of Subdivision Approval
Street Zone of Contribution: In Out �
Village Commercial Residential 5°
Owner: f.l�'�,1e7 ��//rC� Installer /��
Builder: En�ineer !� �tl��d»
�
�331/ ? �
N/A YES NO
1. Re uired number of co ies received.
2. Date of soils exam and ercol tion te t n t ol er than 2 ears.
3. 4 feet of naturallv occurrin�pervious material above water table(new constructionZ
4. Foundation 2 feet above high point of fronting road for new construction s, �
5. �Water availabilitv letter from Water Department for new construction �-'
6 Benchmark indicated and shown-NGVD if near wetlands �---
�7. Building sewer does not Exit center of house. �"
8.-Se tic tank a minimum of 10 fe t fro use and deck. ✓
. 9. Leachin a minimum f 2 feet fro h s and 10 feet fr m deck.
10. Leaching a minimum of 100 feet from wetlands
11. Leac�ing a minimum of 150 feet from drinking wells/25 feet from irrigation wells ✓'"
12. Svstem meets all other setback requirements. ,��
13. Uses adjustment for maximum high groundwater.
14. Leac�iin 4 -5 feet above ad'usted water table or bott o test 't.
15. S stem not in to or subsoi r foot r moval.
16. Proposed contours are suitable.
' 17. Svstem meets slo e re iremen s - ' 1/8" 1/4" ref rred
18. Svstem meets bre kout r uirem ts- a tone elevati n carried out 15 f e minimum.
; 19. S ecified tee sizes are ro er as ba e on outlet tee.
' 20. Sewage flow under 10.000 gnd for t�arcel. ,.-�
21. No earbage disposal.
22. Svstem ade uatelv ized f r it inten e u e
23. Minunum 6" stone or mechanicallv com acted below the tank and d-box.
24. Manhole covers within 6" of grade - septic tank and pump chamber ��
25. Electrical permit for pumn chamber. ✓
�6. Pumn svstem - 2" line. weep hole. check valve sanitarv in d-box alarm on separate circuit �
27. Se tic ank and um ch er to Factorv water�roofed. L.i
28. Vent orovided i leachui� below 3 feet or under driveway or p�rking ..�
�9 Engmeer to mspect and certifv • cla r moval
b. wall construction schedule
c: commercial svstem ��� '
30. En ineer and Land Surve or stam and si nature. �
3l. H20 loadin� when sy.stem subject to vehicular traffic
32. Title V a lic tion and f e si ed b a licen ed installer _�J'
33. Foundation footine 2 feet above adiusted water table -
34. Lot subdivided rior to Jul 31 1986 - Nitrate Loadin �-�
35. Subdivided prior io Apri17. 1989 - Phosphorus Zone 300'
Plan reviewed bv: